Difference between revisions of "2-Neutron Correlation Setup Stuff"
Jump to navigation
Jump to search
(Created page with '== Big Detector Solid Angle Calculations == ; MCNPX Simulation <br /> * 14 MeV neutron source, emitted isotropically (<math>4\pi</math>)<br /> * Detector placed 1m away from sou…') |
|||
Line 49: | Line 49: | ||
[[File:1MeV_Concrete.jpg | 600px]] | [[File:1MeV_Concrete.jpg | 600px]] | ||
− | [Go Back] | + | [https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] |
Revision as of 18:35, 8 June 2012
Big Detector Solid Angle Calculations
- MCNPX Simulation
- 14 MeV neutron source, emitted isotropically (
- Detector placed 1m away from source
- face of the detector is 15.24cm x 76.2cm, and 3.6cm deep
The solid angle can be found from the number of particles hitting the detector as:
- Results
- Out of 1E9 neutrons generated, 8618287 neutrons hit the detector
- if the detector is placed 70cm away from the source,
- if the detector is placed 65cm away from the source,
- As a test to verify our results
- We change the detector size to 2cm by 2cm and used 1E9 neutrons again
- 32061 neutrons struck the detector
- And, as a second test to verify our results
- We change the detector size to 1cm by 1cm and used 1E9 neutrons again
- 7965 neutrons struck the detector
- Now, what neutron singles rate into the detector should correspond to 1 fission per pulse?
- If we have 1 fission per pulse and each fission emits on average 2.3 neutrons, we should expect 2.3 neutrons/pulse
- The number of neutrons hitting the detector per pulse is found as
- @ 1 meter => 0.0198 neutrons hitting the detector per pulse
- @ 70 cm => 0.0379 neutrons hitting the detector per pulse
- Taking into account the efficiency of the detector
- @ 1 meter from source => ( ) neutrons detected per pulse
- @ 70 cm from source => ( ) neutrons detected per pulse
, the number detected per pulse can be found as
Neutron and Photon Flux Through Lead
Using MCNPX, a simulation was done to determine how much of the neutrons and photons from the target will be blocked by various thickness of lead. With a monochromatic pencil beam of incident particles, the following results illustrate how much of the initial beam actually made it through the lead.