Difference between revisions of "Beamline Parts"
Jump to navigation
Jump to search
Line 68: | Line 68: | ||
IPC - 0062 | IPC - 0062 | ||
− | [http://www.pascaltechnologies.com/files%5CPumps%5CIon%20Pumps%5CVarian%5CVarian%20921-0062%20Ion%20Pump%20Controller%20Manual.pdf] | + | pump manual: [http://www.pascaltechnologies.com/files%5CPumps%5CIon%20Pumps%5CVarian%5CVarian%20921-0062%20Ion%20Pump%20Controller%20Manual.pdf] |
[[File:DUNIWAY_ION_PUMP_Manual.pdf]] | [[File:DUNIWAY_ION_PUMP_Manual.pdf]] |
Revision as of 04:14, 18 May 2011
Mini UHV gate valve
Valve with pneumatic actuator:
single acting with closing spring (NC)
ISO-KF and CF-F
Manual: File:Mini UHV gate valve Manual.pdf
Leak rate: body / valve seat:
Pressure range:
mbar to 2 bar (abs)1 millibar = 0.750061683 torr = 0.75 torr
The 24 VDC is for the solenoid. The large round connector in your photos is for the electrical position indicators. The contact rating is up to 50 VDC at 3 A or 250 VAC at 5 A max.
Sadiq, You require 55 – 100 psig into the solenoid. Applying 24 VDC to the solenoid will open the valve and removing it will close the valve. Your valve is a normally closed valve, meaning it is spring closed. Reference the part number in the manual that ends in 41. Give me a call If you have any questions. Regards, Bill McPheeters VAT Sales Engineer - Austin, TX T: 512-280-8050, F: 512-280-8054
Solenoid pinning:
Apply 24 volts between Pin 1 and Pin 2 (
)
Pin 1: +
Pin 2: -
Ground:
My wiring:
Black = hot
White = neutral
Green = ground
Parts needed
Relay (switch), sensor and bus (terminal).
Ion Pump
DUNIWAY
STOCKROOM CORP.
ION PUMP CONTROL UNIT
IPC - 0062
pump manual: [2]
File:DUNIWAY ION PUMP Manual.pdf
Gun