Difference between revisions of "Beamline Parts"

From New IAC Wiki
Jump to navigation Jump to search
Line 21: Line 21:
  
 
  The 24 VDC is for the solenoid.
 
  The 24 VDC is for the solenoid.
 
 
  The large round connector in your photos is for the electrical position indicators. The contact rating is up to 50 VDC at 3 A or 250 VAC at 5 A max.
 
  The large round connector in your photos is for the electrical position indicators. The contact rating is up to 50 VDC at 3 A or 250 VAC at 5 A max.
  

Revision as of 23:13, 4 May 2011

Mini UHV gate valve

Valve with pneumatic actuator:

single acting with closing spring (NC)

ISO-KF and CF-F

Manual: File:Mini UHV gate valve Manual.pdf

File:Mini UHV gate valve.pdf

[1]

Leak rate: body / valve seat: [math] \lt 5 \times 10^{-10}/ \lt 1 \times 10^{-9}~mbar~Is^{-1} [/math]

Pressure range: [math] 1 \times 10{-10} [/math] mbar to 2 bar (abs)

1 millibar = 0.750061683 torr = 0.75 torr


The 24 VDC is for the solenoid.
The large round connector in your photos is for the electrical position indicators. The contact rating is up to 50 VDC at 3 A or 250 VAC at 5 A max.


Sadiq,

You require 55 – 100 psig into the solenoid.   Applying 24 VDC to the solenoid will open the valve and removing it will close the  valve.

Your valve is a normally closed valve, meaning it is spring closed.  Reference the part number in the manual that ends in 41.

Give me a call If you have any questions.

Regards,

Bill McPheeters
VAT Sales Engineer - Austin, TX
T: 512-280-8050, F: 512-280-8054