Difference between revisions of "Neutron Polarimeter"
Line 4: | Line 4: | ||
= Four-vector Algebra = | = Four-vector Algebra = | ||
− | Consider | + | Consider two bode reaction <math>D(\gamma, n)p</math>: |
[[File:Collision01.png | 450 px]] | [[File:Collision01.png | 450 px]] |
Revision as of 03:39, 6 April 2011
Four-vector Algebra
Consider two bode reaction
:
Write down four-momentum vectors before and after reaction:
Now apply the law of conservation of four-momentum vectors:
Squaring both side of equation above and using the four-momentum invariants
we have:
Detector located at case
Detector is located at
, and the formula above is simplified:
We can easily solve the equation above with respect to incident photon energy:
For non-relativistic neutrons and the formula above is become:
Substituting the corresponding masses, we get finally:
and visa versa:
Here I derived the formula [2] just inversing the formula [1]. I can as well start from exact solution above, solve this equation with respect to neutron energy, do the non-relativistic approximation and get exactly the same formula [2]. But anyway we ended up with two useful non-relativistic formulas we can analyze now:
1) from formula [1] above we can predict the threshold of reaction in direction:
2) from formula [1] above we can predict the incident photon energy based on the detected neutron energy (neutron polarimeter).
3) from formula [2] above we can predict the detected neutron energy based on the incident photon energy.
- for the incident photons up towe can detect neutrons up to
- for the incident photons up towe can detect neutrons up to
4) we can do the error calculations.
Example of error calculation (need to be checked)
example 1
Say, we have, 10 MeV neutron with uncertainty 1 MeV, the corresponding uncertainly for photons energy is:
example 2
In the calculations below I attempted to predict the uncertainty in photons energy based on uncertainly of neutrons time of flight.
Say, the neutron's time of flight uncertainty is:
The neutron kinetic energy is:
By taking derivative of the expression above we can find the relative neutron energy error:
Also we need to know the neutron time of flight as function of the neutron energy:
Say, we have 10 MeV neutron, 1.5 m away detector, and neutron's time of flight uncertainty is
.
Using the formulas above we can find:
Below are some calculations for different neutron energy based on time flight uncertainty
:1 ns | 1.5 m | 0.1 MeV | 0.015 | 343 ns | 0.0006 MeV | 0.6 % | 0.0012 MeV | 0.07 % |
1 ns | 1.5 m | 0.5 MeV | 0.033 | 153 ns | 0.006 MeV | 1.3 % | 0.013 MeV | 0.5 % |
1 ns | 1.5 m | 1.0 MeV | 0.046 | 108 ns | 0.02 MeV | 1.9 % | 0.04 MeV | 1.0 % |
1 ns | 1.5 m | 2.0 MeV | 0.065 | 77 ns | 0.05 MeV | 2.6 % | 0.11 MeV | 1.9 % |
1 ns | 1.5 m | 5.0 MeV | 0.103 | 49 ns | 0.21 MeV | 4.1 % | 0.41 MeV | 3.6 % |
1 ns | 1.5 m | 10.0 MeV | 0.145 | 35 ns | 0.59 MeV | 5.9 % | 1.18 MeV | 5.5 % |
1 ns | 1.5 m | 20.0 MeV | 0.203 | 25 ns | 1.68 MeV | 8.4 % | 3.36 MeV | 8.1 % |