Neutron Polarimeter: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Shaproma (talk | contribs)
Shaproma (talk | contribs)
Line 32: Line 32:
We can easily solve the equation above with respect to incident photon energy:  
We can easily solve the equation above with respect to incident photon energy:  


  <math>T_{\gamma} = \frac {m_p^2 - m_n^2 - m_D^2 + 2\ m_D E_n}{2\ (m_D - E_n)} </math>
  <math>T_{\gamma} = \frac {m_p^2 - m_n^2 - m_D^2 + 2\ m_D E_n}{2\ (m_D - E_n)}
                  =  <math>T_{\gamma} = \frac {m_p^2 - m_n^2 - m_D^2 + 2\ m_D (T_n+m_n)}{2\ (m_D - (T_n+m_n))} </math></math>


For non-relativistic neutrons <math>T_n \ll m_n = 939.5\ MeV</math> and
For non-relativistic neutrons <math>T_n \ll m_n = 939.5\ MeV</math> and

Revision as of 18:19, 5 April 2011

Go Back


Four-vector Algebra


Let's do the four-vector algebra:

[math]\displaystyle{  p_{\gamma} = \left( T_{\gamma},\ T_{\gamma},\ 0,\ 0  \right)  }[/math] 
[math]\displaystyle{  p_D     = \left( m_D,\ 0,\ 0,\ 0  \right)  }[/math] 
[math]\displaystyle{  p_{n} = \left( E_n,\ \ p_n\cos \Theta_n,\ \ p_n\sin \Theta_n,\ \ 0  \right)  }[/math] 
[math]\displaystyle{  p_{p} = \left( E_p,\ \ p_p\cos \Theta_p,\ \ p_p\sin \Theta_p,\ \ 0  \right)  }[/math] 

By conservation of four-momentum:

[math]\displaystyle{  p^{\mu}_{\gamma} + p^{\mu}_D = p^{\mu}_p + p^{\mu}_n\ \ \Rightarrow \ \  p^{\mu}_p = p^{\mu}_{\gamma} + p^{\mu}_D - p^{\mu}_n }[/math]

Squaring both side of equation above and using the four-momentum invariants [math]\displaystyle{ (p^{\mu})^2 = m^2 }[/math] we have:

[math]\displaystyle{  m_p^2 = m_D^2 + m_n^2 +  2T_{\gamma}\cdot m_D  - 2m_D\cdot E_n - 2\left( T_{\gamma}E_n - T_{\gamma}p_n\cos\Theta_n\right)  }[/math]


Detector located at [math]\displaystyle{ \Theta = 90^o }[/math] case

Detector is located at [math]\displaystyle{ \Theta_n = 90^o }[/math], and the formula above is simplified:

[math]\displaystyle{  m_p^2 = m_D^2 + m_n^2 +  2\ T_{\gamma}\cdot m_D  - 2\ m_D\cdot E_n - 2\ T_{\gamma}E_n  }[/math]

We can easily solve the equation above with respect to incident photon energy:

[math]\displaystyle{ T_{\gamma} = \frac {m_p^2 - m_n^2 - m_D^2 + 2\ m_D E_n}{2\ (m_D - E_n)}
                  =  <math>T_{\gamma} = \frac {m_p^2 - m_n^2 - m_D^2 + 2\ m_D (T_n+m_n)}{2\ (m_D - (T_n+m_n))}  }[/math]</math>

For non-relativistic neutrons [math]\displaystyle{ T_n \ll m_n = 939.5\ MeV }[/math] and

[math]\displaystyle{ T_{\gamma} = \frac {m_p^2 - m_n^2 - m_D^2 + 2\ m_D m_n + 2\ m_D T_n}{2\ (m_D - m_n)}  }[/math]


Substituting the corresponding masses, we get finally for the case of non-relativistic neutrons detected at the angle [math]\displaystyle{ \Theta_n = 90^o }[/math]:

[math]\displaystyle{ T_{\gamma}\ [MeV] = 2.003\ T_n\ [MeV] + 1.577\ [MeV] }[/math]

and visa versa:

[math]\displaystyle{ T_n\ [MeV] = 0.499\ T_{\gamma}\ [MeV] - 0.787\ [MeV] }[/math]


Using the formulas above we can:


1. Calculate the threshold for [math]\displaystyle{ ^2D(n,\gamma) }[/math] reaction:

[math]\displaystyle{ E_{\gamma} = 1.577\ MeV }[/math]

2. Predict the incident photon energy based on the detected neutron energy.

3. Predict the detected neutron energy based on the incident photon energy.

 -  for the incident photons up to 25 MeV we have (0 - 11.69) MeV neutrons
 -  for the incident photons up to 44 MeV we have (0 - 21.17) MeV neutrons



Also note:

and visa versa

 [math]\displaystyle{  T_n = \frac {2\ T_{\gamma}\ m_D + m_D^2 + m_n^2 - m_p^2} {2\left( T_{\gamma} + m_D \right)} - m_n }[/math]

how it looks


low energy approximation=

As we can see from Fig.2 for low energy neutrons (0-21 MeV)
energy dependence of incident photons is linear
Find that dependence. We have:
[math]\displaystyle{ T_{\gamma}(0\ MeV) = 1.715360792\ MeV }[/math] [math]\displaystyle{ T_{\gamma}(21\ MeV) = 44.78703086\ MeV }[/math]
So, the equation of the line is:
[math]\displaystyle{ T_{\gamma} = \frac{T_{\gamma}(21\ MeV) - T_{\gamma}(0\ MeV)}{21\ MeV - 0\ MeV}\ T_n + T_{\gamma}(0\ MeV) }[/math]
Finally for low energy neutrons (0-21 MeV):
[math]\displaystyle{ T_{\gamma} = 2.051\ T_n + 1.715 }[/math]

example of error calculation

example 1

Say, we have, 10 MeV neutron with uncertainty 1 MeV, the corresponding uncertainly for photons energy is:

[math]\displaystyle{  \delta T_{\gamma} = 2.051\ \delta T_n = 2.051\times 1\ MeV = 2.051\ MeV  }[/math]

example 2

Say, the neutron's time of flight uncertainly is 1 ns

The neutron's kinetic energy is:

[math]\displaystyle{ T_n = m_n (\gamma - 1) = m_n\left[ \frac{1}{\sqrt{1-\left(\frac{l}{c\ t}\right)^2}} - 1 \right] }[/math]

And:

[math]\displaystyle{ \delta T_n \left(\delta t\right) = -\ \frac{m\ l^2 \delta t}{\left(1-\left(\frac{l}{c\ t}\right)^2\right)^{3/2}c^2 t^3} }[/math]


Also we need the neutron's time of flight as function of neutron's kinetic energy:

[math]\displaystyle{ t:=\frac{l}{c\ \beta_n} = \frac{l}{c\ (p_n/E_n)} =
         \frac{l\ (T_n + m_n)}{c\sqrt{T_n^2+2m_nT_n}} }[/math]


Say, we have 10 MeV neutron, 1 m away detector, and neutron's time of flight uncertainty is 1 ns. Then the neutron time of flight is:


[math]\displaystyle{ t(T_n = 10\ MeV) = 23\ ns }[/math]   


Neutron kinetic energy errors are:

[math]\displaystyle{ \delta T_n(\delta t = 1\ ns) = 0.88\ MeV }[/math]
[math]\displaystyle{ \frac{\delta T_n}{T_n} = \frac{0.88\ MeV}{10\ MeV} = 8.8\ % }[/math] 


And photon energy errors are:

[math]\displaystyle{ \delta T_{\gamma} = 2.051\cdot \delta T_n = 2.051\cdot 0.88\ MeV = 1.81\ MeV  }[/math] 
[math]\displaystyle{ \frac{\delta T_{\gamma}}{T_{\gamma}} = \frac{1.80\ MeV}{(2.051\cdot 10 + 1.715)\ MeV} = 8.1\ % }[/math]


Below are some examples for different detector distance and neutron kinetic energy:

[math]\displaystyle{ \delta t_n }[/math] [math]\displaystyle{ l }[/math] [math]\displaystyle{ T_n }[/math] [math]\displaystyle{ \beta_n }[/math] [math]\displaystyle{ t_n }[/math] [math]\displaystyle{ \delta T_n }[/math] [math]\displaystyle{ \frac{\delta T_n}{T_n} }[/math] [math]\displaystyle{ \delta T_{\gamma} }[/math] [math]\displaystyle{ \frac{\delta T_{\gamma}}{T_{\gamma}} }[/math]
1 ns 1 m 5 MeV 0.103 32 ns 0.31 MeV 6.2 % 0.64 MeV 5.3 %
1 ns 1 m 10 MeV 0.145 23 ns 0.88 MeV 8.8 % 1.81 MeV 8.1 %
1 ns 1 m 20 MeV 0.203 16 ns 2.51 MeV 12.6 % 5.16 MeV 12.1 %
1 ns 1 m 0.5 MeV 0.033 102 ns 0.010 MeV 1.9 %
1 ns 1 m 1 MeV 0.046 72 ns 0.028 MeV 2.8 %
1 ns 1 m 2 MeV 0.065 51 ns 0.078 MeV 3.9 %
1 ns 1 m 4 MeV 0.092 36 ns 0.22 MeV 5.5 %




Go Back