Neutron Polarimeter: Difference between revisions
| Line 28: | Line 28: | ||
Detector is located at <math>\Theta_n = 90^o</math>, and the formula above is simplified: | Detector is located at <math>\Theta_n = 90^o</math>, and the formula above is simplified: | ||
<math> m_p^2 = m_D^2 + m_n^2 + | <math> m_p^2 = m_D^2 + m_n^2 + 2\ T_{\gamma}\cdot m_D - 2\ m_D\cdot E_n - 2\ T_{\gamma}E_n </math> | ||
We can easily solve the equation above with respect to incident photon energy: | We can easily solve the equation above with respect to incident photon energy: | ||
Revision as of 18:15, 5 April 2011
Four-vector Algebra
Let's do the four-vector algebra:
[math]\displaystyle{ p_{\gamma} = \left( T_{\gamma},\ T_{\gamma},\ 0,\ 0 \right) }[/math] [math]\displaystyle{ p_D = \left( m_D,\ 0,\ 0,\ 0 \right) }[/math] [math]\displaystyle{ p_{n} = \left( E_n,\ \ p_n\cos \Theta_n,\ \ p_n\sin \Theta_n,\ \ 0 \right) }[/math] [math]\displaystyle{ p_{p} = \left( E_p,\ \ p_p\cos \Theta_p,\ \ p_p\sin \Theta_p,\ \ 0 \right) }[/math]
By conservation of four-momentum:
[math]\displaystyle{ p^{\mu}_{\gamma} + p^{\mu}_D = p^{\mu}_p + p^{\mu}_n\ \ \Rightarrow \ \ p^{\mu}_p = p^{\mu}_{\gamma} + p^{\mu}_D - p^{\mu}_n }[/math]
Squaring both side of equation above and using the four-momentum invariants [math]\displaystyle{ (p^{\mu})^2 = m^2 }[/math] we have:
[math]\displaystyle{ m_p^2 = m_D^2 + m_n^2 + 2T_{\gamma}\cdot m_D - 2m_D\cdot E_n - 2\left( T_{\gamma}E_n - T_{\gamma}p_n\cos\Theta_n\right) }[/math]
Detector located at [math]\displaystyle{ \Theta = 90^o }[/math] case
Detector is located at [math]\displaystyle{ \Theta_n = 90^o }[/math], and the formula above is simplified:
[math]\displaystyle{ m_p^2 = m_D^2 + m_n^2 + 2\ T_{\gamma}\cdot m_D - 2\ m_D\cdot E_n - 2\ T_{\gamma}E_n }[/math]
We can easily solve the equation above with respect to incident photon energy:
[math]\displaystyle{ T_{\gamma} = \frac {m_p^2 - m_n^2 - m_D^2 + 2\ m_D E_n}{2\ (m_D - E_n)} }[/math]
For non-relativistic neutrons [math]\displaystyle{ T_n \ll m_n = 939.5\ MeV }[/math] and
[math]\displaystyle{ T_{\gamma} = \frac {m_p^2 - m_n^2 - m_D^2 + 2\ m_D m_n + 2\ m_D T_n}{2\ (m_D - m_n)} }[/math]
Substituting the corresponding masses, we get finally for the case of non-relativistic neutrons detected at the angle [math]\displaystyle{ \Theta_n = 90^o }[/math]:
[math]\displaystyle{ T_{\gamma}\ [MeV] = 2.003\ T_n\ [MeV] + 1.577\ [MeV] }[/math]
and visa versa:
[math]\displaystyle{ T_n\ [MeV] = 0.499\ T_{\gamma}\ [MeV] - 0.787\ [MeV] }[/math]
Using the formulas above we can:
1. Calculate the threshold for [math]\displaystyle{ ^2D(n,\gamma) }[/math] reaction:
[math]\displaystyle{ E_{\gamma} = 1.577\ MeV }[/math]
2. Predict the incident photon energy based on the detected neutron energy.
3. Predict the detected neutron energy based on the incident photon energy.
- for the incident photons up to 25 MeV we have (0 - 11.69) MeV neutrons
- for the incident photons up to 44 MeV we have (0 - 21.17) MeV neutrons
Also note:
and visa versa
[math]\displaystyle{ T_n = \frac {2\ T_{\gamma}\ m_D + m_D^2 + m_n^2 - m_p^2} {2\left( T_{\gamma} + m_D \right)} - m_n }[/math]
how it looks
low energy approximation=
As we can see from Fig.2 for low energy neutrons (0-21 MeV)
energy dependence of incident photons is linear
Find that dependence. We have:
[math]\displaystyle{ T_{\gamma}(0\ MeV) = 1.715360792\ MeV }[/math] [math]\displaystyle{ T_{\gamma}(21\ MeV) = 44.78703086\ MeV }[/math]
So, the equation of the line is:
[math]\displaystyle{ T_{\gamma} = \frac{T_{\gamma}(21\ MeV) - T_{\gamma}(0\ MeV)}{21\ MeV - 0\ MeV}\ T_n + T_{\gamma}(0\ MeV) }[/math]
Finally for low energy neutrons (0-21 MeV):
[math]\displaystyle{ T_{\gamma} = 2.051\ T_n + 1.715 }[/math]
example of error calculation
example 1
Say, we have, 10 MeV neutron with uncertainty 1 MeV, the corresponding uncertainly for photons energy is:
[math]\displaystyle{ \delta T_{\gamma} = 2.051\ \delta T_n = 2.051\times 1\ MeV = 2.051\ MeV }[/math]
example 2
Say, the neutron's time of flight uncertainly is 1 ns
The neutron's kinetic energy is:
[math]\displaystyle{ T_n = m_n (\gamma - 1) = m_n\left[ \frac{1}{\sqrt{1-\left(\frac{l}{c\ t}\right)^2}} - 1 \right] }[/math]
And:
[math]\displaystyle{ \delta T_n \left(\delta t\right) = -\ \frac{m\ l^2 \delta t}{\left(1-\left(\frac{l}{c\ t}\right)^2\right)^{3/2}c^2 t^3} }[/math]
Also we need the neutron's time of flight as function of neutron's kinetic energy:
[math]\displaystyle{ t:=\frac{l}{c\ \beta_n} = \frac{l}{c\ (p_n/E_n)} =
\frac{l\ (T_n + m_n)}{c\sqrt{T_n^2+2m_nT_n}} }[/math]
Say, we have 10 MeV neutron, 1 m away detector, and neutron's time of flight uncertainty is 1 ns. Then the neutron time of flight is:
[math]\displaystyle{ t(T_n = 10\ MeV) = 23\ ns }[/math]
Neutron kinetic energy errors are:
[math]\displaystyle{ \delta T_n(\delta t = 1\ ns) = 0.88\ MeV }[/math] [math]\displaystyle{ \frac{\delta T_n}{T_n} = \frac{0.88\ MeV}{10\ MeV} = 8.8\ % }[/math]
And photon energy errors are:
[math]\displaystyle{ \delta T_{\gamma} = 2.051\cdot \delta T_n = 2.051\cdot 0.88\ MeV = 1.81\ MeV }[/math] [math]\displaystyle{ \frac{\delta T_{\gamma}}{T_{\gamma}} = \frac{1.80\ MeV}{(2.051\cdot 10 + 1.715)\ MeV} = 8.1\ % }[/math]
Below are some examples for different detector distance and neutron kinetic energy:
| [math]\displaystyle{ \delta t_n }[/math] | [math]\displaystyle{ l }[/math] | [math]\displaystyle{ T_n }[/math] | [math]\displaystyle{ \beta_n }[/math] | [math]\displaystyle{ t_n }[/math] | [math]\displaystyle{ \delta T_n }[/math] | [math]\displaystyle{ \frac{\delta T_n}{T_n} }[/math] | [math]\displaystyle{ \delta T_{\gamma} }[/math] | [math]\displaystyle{ \frac{\delta T_{\gamma}}{T_{\gamma}} }[/math] |
| 1 ns | 1 m | 5 MeV | 0.103 | 32 ns | 0.31 MeV | 6.2 % | 0.64 MeV | 5.3 % |
| 1 ns | 1 m | 10 MeV | 0.145 | 23 ns | 0.88 MeV | 8.8 % | 1.81 MeV | 8.1 % |
| 1 ns | 1 m | 20 MeV | 0.203 | 16 ns | 2.51 MeV | 12.6 % | 5.16 MeV | 12.1 % |
| 1 ns | 1 m | 0.5 MeV | 0.033 | 102 ns | 0.010 MeV | 1.9 % | ||
| 1 ns | 1 m | 1 MeV | 0.046 | 72 ns | 0.028 MeV | 2.8 % | ||
| 1 ns | 1 m | 2 MeV | 0.065 | 51 ns | 0.078 MeV | 3.9 % | ||
| 1 ns | 1 m | 4 MeV | 0.092 | 36 ns | 0.22 MeV | 5.5 % |