Difference between revisions of "CHIPS IAC Run 5-29-08"

From New IAC Wiki
Jump to navigation Jump to search
Line 82: Line 82:
 
|-
 
|-
 
|56|| NaI056.mpa || IN || In|| Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV.  48<math>\pm</math> 8 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.
 
|56|| NaI056.mpa || IN || In|| Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV.  48<math>\pm</math> 8 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.
 +
|-
 +
|57|| NaI057.mpa || IN || Out|| Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV.  <math>\pm</math>  counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.
 
|}
 
|}
  
  
 
[http://www.iac.isu.edu/mediawiki/index.php/CHIPS_Run_May-2008 Go Back]
 
[http://www.iac.isu.edu/mediawiki/index.php/CHIPS_Run_May-2008 Go Back]

Revision as of 15:42, 29 May 2008

Calibration

Run # MPA file name Description
40 NaI040.mpa Na-22 source in front of HpGe and Co-60 on top of NaI detector
41 NaI019.mpa Co-60 source in front of HpGe and Na-22 on top of NaI detector

Last Dipole Sweep

Tune 10 Mev onto Tungsten and 4 MeV into Cell

We put in two thin pieces (thickness ~1/4" each) making a ~1/2" of lead angled at ~30 degrees wrt vertical between the NaI detector and the collimator to cut down on low-energy (< 200 keV) photons.


Run # MPA file name W Ta Description
45 NaI045.mpa IN IN Dipole at 2 MeV (0.78 on Pot), 60 Hz rep rate
46 NaI046.mpa IN IN Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 116 [math]\pm[/math] 15 counts at 500 keV, Live=929 seconds
47 NaI047.mpa IN Out Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 53 [math]\pm[/math] 9 counts at 500 keV, Live=607 seconds, (Tant IN/Out ratio =116/53 [math]\times[/math] 607/929 = 1.4)
48 NaI048.mpa IN Out Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 90 [math]\pm[/math] 11 counts at 500 keV, Live=600 seconds, ignore NaI (cable not plugged into scope)
49 NaI049.mpa IN In Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 113[math]\pm[/math] 12 counts at 500 keV, Live=634 seconds,plugged NaI cable back into scope in middle of run. ((Tant IN/Out ratio =113/90 = 1.26 )


Accelerator Gun problem (ground wire shielding was worn away and creating path for short)


Restore tune with settings below.:

Device setting
RS1 0+
RS2 0-
FS1 0+
FS2 0-
0Q1 -0.20
0Q2 +2.86
45Q1 -0.004
45Q2 +2.24
L90Q1 -1.33
L90Q2 +2.42
Bend1 3.5
Bend2 0.86
Gun HV 13 kV
Grid 2.31
802 16 kV
SOL1 0.39
SOL2 0.40
Run # MPA file name W Ta Description
56 NaI056.mpa IN In Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 48[math]\pm[/math] 8 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.
57 NaI057.mpa IN Out Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. [math]\pm[/math] counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.


Go Back