Difference between revisions of "PbF2 CrystalNumber18"
Jump to navigation
Jump to search
Line 59: | Line 59: | ||
=12/5/07= | =12/5/07= | ||
+ | |||
+ | ;Transparency measurement (12:35) | ||
+ | |||
+ | |||
+ | ;Accelerator Settings | ||
+ | {| border="1" | ||
+ | | beam energy || 20 MeV | ||
+ | |- | ||
+ | | Rep Rate: || 30 Hz | ||
+ | |- | ||
+ | | I_peak: || 60 mA/pulse | ||
+ | |- | ||
+ | | pulse width:|| 0.1 <math>\mu</math>s (100 ns) | ||
+ | |- | ||
+ | |beam start: || 12:54 | ||
+ | |- | ||
+ | |beam stop: || | ||
+ | |} | ||
+ | |||
[http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back] | [http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back] |
Revision as of 19:57, 5 December 2007
Below are the resulting transparency measurements for PbF2 block # 18
12/4/07
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 10:42 |
beam stop: | 12:42 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns
- Dose rate measurements (@1255 hours)
-radiation | 500 uR/hr |
-radiation: | 500 uR/hr |
- Transparency Measurements (@1525 hours)
12/5/07
- Transparency measurement (12
- 35)
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 12:54 |
beam stop: |