Difference between revisions of "PbF2 CrystalNumber18"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
| Line 59: | Line 59: | ||
| =12/5/07= | =12/5/07= | ||
| + | |||
| + | ;Transparency measurement (12:35) | ||
| + | |||
| + | |||
| + | ;Accelerator Settings | ||
| + | {| border="1" | ||
| + | | beam energy || 20 MeV | ||
| + | |- | ||
| + | | Rep Rate: ||   30 Hz | ||
| + | |- | ||
| + | | I_peak:     || 60 mA/pulse | ||
| + | |- | ||
| + | | pulse width:|| 0.1 <math>\mu</math>s (100 ns) | ||
| + | |- | ||
| + | |beam start: || 12:54 | ||
| + | |- | ||
| + | |beam stop: ||  | ||
| + | |} | ||
| + | |||
| [http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back] | [http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back] | ||
Revision as of 19:57, 5 December 2007
Below are the resulting transparency measurements for PbF2 block # 18
12/4/07
- Accelerator Settings
| beam energy | 20 MeV | 
| Rep Rate: | 30 Hz | 
| I_peak: | 60 mA/pulse | 
| pulse width: | 0.1 s (100 ns) | 
| beam start: | 10:42 | 
| beam stop: | 12:42 | 
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt ns
- Dose rate measurements (@1255 hours)
| -radiation | 500 uR/hr | 
| -radiation: | 500 uR/hr | 
- Transparency Measurements (@1525 hours)
12/5/07
- Transparency measurement (12
- 35)
- Accelerator Settings
| beam energy | 20 MeV | 
| Rep Rate: | 30 Hz | 
| I_peak: | 60 mA/pulse | 
| pulse width: | 0.1 s (100 ns) | 
| beam start: | 12:54 | 
| beam stop: |