Line 8: | Line 8: | ||
− | {| class="wikitable" align="center" border=1 | + | <center>{| class="wikitable" align="center" border=1 |
|+ '''Rates''' | |+ '''Rates''' | ||
|- | |- | ||
Line 26: | Line 26: | ||
|- | |- | ||
| N_{incident} || 4E7 ||4E8 ||6E7 || 6E7 | | N_{incident} || 4E7 ||4E8 ||6E7 || 6E7 | ||
− | |} | + | |}</center> |
Total dectector events occur for about 2.5% of the incident electrons on a LH2 target. We can assume that the Moller rate is 95% of the total event rate. We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well. Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material | Total dectector events occur for about 2.5% of the incident electrons on a LH2 target. We can assume that the Moller rate is 95% of the total event rate. We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well. Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material |
Revision as of 16:53, 26 March 2018
|+ Rates |- | Simulation || GEANT4(1cm target) ||GEANT4(1cm target)|| GEANT4(5cm target) || Whitney |- | Event Cross-Section (b) || 0.61 || 0.61|| 0.38 || 0.079 |- |Moller Cross-Section (b) || 0.58||0.58 || 0.361 || 0.075 |- | Length of Target (cm) || 1 || 1 ||5 ||5 |- | t_{simulated} (s) || 1.3E-5 ||1.3E-4 || 9.8E-4 ||9.54E-5 |- | N_{events} || 1026940 || 10270829|| 4826141 || 1001700 |- | N_{Moller} || 975593 || 9757288|| 4584834 || 951138 |- | N_{incident} || 4E7 ||4E8 ||6E7 || 6E7
|}
Total dectector events occur for about 2.5% of the incident electrons on a LH2 target. We can assume that the Moller rate is 95% of the total event rate. We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well. Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material