Difference between revisions of "Determining wire-theta correspondence"
Line 9: | Line 9: | ||
− | =Determine Wire-Theta Correspondence= | + | =5.1.1 Determine a Wire-Theta Correspondence= |
To associate the hits with the Moller scattering angle theta, the occupancy plots of the drift chamber hits by means of wire numbers and layer must be translated using the physical constraints of the detector. Using the data released for the DC: | To associate the hits with the Moller scattering angle theta, the occupancy plots of the drift chamber hits by means of wire numbers and layer must be translated using the physical constraints of the detector. Using the data released for the DC: | ||
Line 20: | Line 20: | ||
<center> | <center> | ||
{| border=1 | {| border=1 | ||
− | |+ Constraints from DC Geometry | + | |+ Table 5.1 Constraints from DC Geometry File |
|- | |- | ||
! Variable | ! Variable |
Revision as of 21:45, 15 May 2017
5.1.1 Determine a Wire-Theta Correspondence
To associate the hits with the Moller scattering angle theta, the occupancy plots of the drift chamber hits by means of wire numbers and layer must be translated using the physical constraints of the detector. Using the data released for the DC:
Variable | Measurement | Definition |
---|---|---|
thtilt | 25 degrees | Tilt relative to z |
dist2tgt | 228.078 cm | Distance from the target to the first guard wire plane along the
normal of said plane |
th_min | 4.694 degrees | Polar angle to the first guard wire’s (in the first guard wire plane) midpoint
where the wire mid-point is the intersection of the wire with the chamber mid-plane |
wpdist | 0.3861 cm | Distance between the wire planes |
At 25 degrees above the beam line direction, we can create a line that is perpendicular to the plane of the wires, which are at 65 degrees above the reverse beam line direction. This line will be a perpendicular line with respect to all parallel layers of wires with respect to the initial guard wire plane. We can use this geometry and dist2tgt, which is the distance from the target to the first guard wire plane along the normal of said plane, to calculate other distances.
Using trigonometry, we can find the distance along the beam line to the intersection with the initial guard wire plane.
The parallel planes of wires are shown in the image below.
The angle th_min is defined as the polar angle to the first guard wire’s (in the first guard wire plane) midpoint
where the wire mid-point is the intersection of the wire with the chamber mid-plane. The first guard wire can be found at 4.694 degrees above the beam line. This position can be taken as the starting position for the wire normal plane.
Using the law of sines
Making a right triangle,
Examining the geometry file, we can see that each plane, not just the plane of the sense wires, is separated by a distance of
We can use the geometry of the wire placements to find the separation distance between two adjacent sense wires on the same plane
The starting position for sense wires with respect to the first guard wire at midplane, can be found to be at:
Since the separation between adjacent sense wires is uniform and at a set angle of 25 degrees with respect to the beam line, we can use this fact to determine the angle theta each wire makes when measured from the vertex.
The new x and z coordinates for wire 2 can be found using the change in the components
This can be extended to any point along the same wire plane, starting from the coordinates for wire 1 minus the difference in position to the next wire crossing on the plane.
The angle theta that the wire makes with the vertex is given by
For the values found earlier for the starting position: