Difference between revisions of "SeRun 02-13-17"

From New IAC Wiki
Jump to navigation Jump to search
Line 11: Line 11:
 
[[File:CS.jpg]]
 
[[File:CS.jpg]]
  
=Production rate in 1 gram of natural Se (or natural Ni)(1/sec)=
+
=Production rate in 1 gram of natural Se (or natural Ni)(1/sec) assuming 22 MeV 1 microA current=
  
 
  {| border="3"  cellpadding="5" cellspacing="0"
 
  {| border="3"  cellpadding="5" cellspacing="0"
 
|  || Tube 1 || Tube 2 || Tube 3 || Tube 4  
 
|  || Tube 1 || Tube 2 || Tube 3 || Tube 4  
 
|-
 
|-
| Ni-57 || 3.82x10^10 || 7.22x10^9 || 1.15x10^9 || 1.25x10^9
+
| Ni-57 || 1.8x10^5 || 3.4x10^4 || 5.5x10^3 || 6.0x10^3
 
|-
 
|-
| Se-79 || 3.81x10^11 || 7.05x10^10 || 1.59x10^10 || 1.54x10^10
+
| Se-79 || 1.5x10^6 || 2.7x10^5 || 6.2x10^4 || 6.0x10^4
 
|-
 
|-
| Se-75 || 5.85x10^10 || 1.09x10^10 || 2.22x10^9 || 2.21x10^9
+
| Se-75 || 1.2x10^6 || 2.3x10^5 || 4.6x10^4 || 4.6x10^4
 
|-  
 
|-  
| Se-80 || 6.19x10^10 ||  1.13x10^10 || 2.67x10^9 || 2.55x10^9
+
| Se-80 || 1.4x10^6 ||  2.4x10^5 || 5.9x10^4 || 5.6x10^4
 
|}
 
|}

Revision as of 19:55, 9 February 2017

PAA_Selenium#SeRun_02-13-17

Selenium Irradiation Setup for MCNP simulations: SeSetup.jpg


MCNP results for photon flux through the samples (electron beam energy is 21 MeV, energy bins are 100 keV, selenium density is 4.2 g/cc, selenium sample is cylindrical, 2 cm in diameter, 2 cm in height): PhFl.jpg

Cross-sections for various reactions (adopted from TALYS): CS.jpg

Production rate in 1 gram of natural Se (or natural Ni)(1/sec) assuming 22 MeV 1 microA current

Tube 1 Tube 2 Tube 3 Tube 4
Ni-57 1.8x10^5 3.4x10^4 5.5x10^3 6.0x10^3
Se-79 1.5x10^6 2.7x10^5 6.2x10^4 6.0x10^4
Se-75 1.2x10^6 2.3x10^5 4.6x10^4 4.6x10^4
Se-80 1.4x10^6 2.4x10^5 5.9x10^4 5.6x10^4