Cf-252 FTC-CFZ-431: Difference between revisions
| Line 11: | Line 11: | ||
{| border="2" | {| border="2" | ||
!rowspan="2"| nuclide !! rowspan="2"| Atom % !! rowspan="2"|NAtoms in 1993 <math>\times | !rowspan="2"| nuclide !! rowspan="2"| Atom % !! rowspan="2"|NAtoms in 1993 <math>\times</math>^15 !! rowspan="2"|<math>T_{1/2}</math> [y] !! colspan="2" | decays <math>[s^{-1}]</math> | ||
|- | |- | ||
!<math>\alpha</math>!! SF | !<math>\alpha</math>!! SF | ||
Revision as of 20:44, 19 January 2017
Overview
An official document for the CF-252 source with serial number FTC-CFZ-431 provides a value for the neutron rate and CF-252 mass as of 03/19/1993.
The initial neutron rate and mass of cf-252 are stated to be [math]\displaystyle{ 10^{7}s^{-1} }[/math] and 4.2[math]\displaystyle{ \mu g }[/math], respectively.
4.2 [math]\displaystyle{ \mu g }[/math] would generate [math]\displaystyle{ 9.67 \times 10^{6} }[/math] neutrons per second. The discrepancy between these two numbers gives a 2% error.
Initial source composition
CF252 used in the US is produced in batches at Oak Ridge National Laboratory which all have similar isotopic make up. I found the isotopic composition of a batch produced in 1991, two years before the production date of our source<ref> http://permalink.lanl.gov/object/tr?what=info:lanl-repo/lareport/LA-UR-12-22883 </ref>. Assuming our source has the same isotopic composition as the 1991 batch and a total mass of 4.2 [math]\displaystyle{ \mu }[/math]g, the values in the following table can be calculated.
| nuclide | Atom % | NAtoms in 1993 [math]\displaystyle{ \times }[/math]^15 | [math]\displaystyle{ T_{1/2} }[/math] [y] | decays [math]\displaystyle{ [s^{-1}] }[/math] | |
|---|---|---|---|---|---|
| [math]\displaystyle{ \alpha }[/math] | SF | ||||
| [math]\displaystyle{ ^{249}Cf }[/math] | 3.41 | - | 351 | ||
Table of rates
Click here to open a table giving neutron rates and C-252 activity from dates 1/2017 to 12/2029. This calculation only includes neutrons from Cf-252, since all other daughter nuclei and possible impurities have a very low SF rate compared to Cf-252.
Formulas
Formula used for neutron rate [[math]\displaystyle{ s^{-1} }[/math]]:
[math]\displaystyle{ k=(0.5)^{\frac{(year-1993)+\frac{month-3}{12}}{2.645}} }[/math]
[math]\displaystyle{ n_{0}rate=9.835\times10^6\times k }[/math]
and for Cf-252 activity [[math]\displaystyle{ \mu Ci }[/math]]:
[math]\displaystyle{ activity=2283.3\times k }[/math]
References