Difference between revisions of "Cf-252 FTC-CFZ-431"
Line 7: | Line 7: | ||
4.2 <math>\mu g</math> would generate <math>9.67 \times 10^{6}</math> neutrons per second. The discrepancy between these two numbers gives a 2% error. | 4.2 <math>\mu g</math> would generate <math>9.67 \times 10^{6}</math> neutrons per second. The discrepancy between these two numbers gives a 2% error. | ||
=initial source composition= | =initial source composition= | ||
− | + | CF252 used in the US is produced in batches at Oak Ridge National Laboratory which all have similar isotopic make up. I was able to find the composition of a batch produced in 1991, two years before the date of our production for our source. | |
=Table of rates= | =Table of rates= |
Revision as of 19:58, 19 January 2017
Overview
An official document for the CF-252 source with serial number FTC-CFZ-431 provides a value for the neutron rate and CF-252 mass as of 03/19/1993.
The initial neutron rate and mass of cf-252 are stated to be
and 4.2 , respectively.4.2
would generate neutrons per second. The discrepancy between these two numbers gives a 2% error.initial source composition
CF252 used in the US is produced in batches at Oak Ridge National Laboratory which all have similar isotopic make up. I was able to find the composition of a batch produced in 1991, two years before the date of our production for our source.
Table of rates
Click here to open a table giving neutron rates and C-252 activity from dates 1/2017 to 12/2029. This calculation only includes neutrons from Cf-252, since all other daughter nuclei and possible impurities have a very low SF rate compared to Cf-252.
Formulas
Formula used for neutron rate [
]:
and for Cf-252 activity [
]: