Difference between revisions of "PAA ResultsFromTheIAC"
Line 37: | Line 37: | ||
[[File:IrradiatedKapton-vsScotchTapeRates_9-22-16.png | 400 px]] | [[File:IrradiatedKapton-vsScotchTapeRates_9-22-16.png | 400 px]] | ||
+ | |||
+ | ==HEU disks== | ||
+ | |||
+ | A 20 MeV electron was used to make a bremsstrahlung beam that impinged HEU disks | ||
+ | |||
[[PAA_Research]] | [[PAA_Research]] |
Revision as of 22:16, 26 September 2016
Scotch Tape -vs- Kapton tape
A 20 MeV electron was used to make a bremsstrahlung beam that impinged a sample of regular Scotch Tape and Kapton tape. Both tapes had similar areas of 2.5 x 3 cm. The Kapton had twice as much mass as the Scotch (0.1247 g -vs 0.0699 g).
The scotch taper became brittle after 4 hours of irradiation on the 25 N machine.
Below is an uncalibrated spectrum using Thorium rods. Lines should appear at 238.8,338.8, 511, 583.4, 911.2, and 2614.6 keV
Channel | Energy (keV) |
242 | 238.8 |
342 | 338.8 |
514 | 511 |
586 | 583 |
914 | 911.2 |
2617 | 2614.6 |
slope=1.0003 +/- 0.000156023 y-intercept=-3.12645 +/- 0.185346
MPA->Draw("-3.12645+1.0003*evt.Chan>>(8000,0,8000)");
Scotch tape run was 6663.4 seconds long (MPA->Draw("-3.12645+1.0003*evt.Chan>>NScotchTape(8000,0,8000)","0.00015");)
Kapton Tape run was 488.44 seconds long (MPA->Draw("-3.12645+1.0003*evt.Chan>>NKaptonTape(8000,0,8000)","0.0020473344");)
HEU disks
A 20 MeV electron was used to make a bremsstrahlung beam that impinged HEU disks