==7/16/16==
==7/17/16==
PMT top and bottom is in coincidence with a trigger placed 3" below the CF-252 source.  
All run information can be seen  [[Signal cable timing|here]]  (thresholds, source positioning, ect).
 
PMT pulses are widened to 500 ns in electronics in order to avoid double counting.
 
 
Discriminator thresholds:
 
Trigger: 35 mv
 
PMT's: 50 mv
 





Revision as of 07:05, 18 August 2016

Go back

7/17/16

All run information can be seen here (thresholds, source positioning, ect).


Detector PMT High voltage
angle color
30 Red Top 1555
Bot 4444