Difference between revisions of "Signal cable timing"
Jump to navigation
Jump to search
Line 60: | Line 60: | ||
| Top | | Top | ||
| D150T005 | | D150T005 | ||
+ | |1 | ||
| +1 <!--Top delta t from D30T001--> | | +1 <!--Top delta t from D30T001--> | ||
| rowspan="2" | +13 <!--Bottom minus top--> | | rowspan="2" | +13 <!--Bottom minus top--> | ||
Line 67: | Line 68: | ||
| Bot | | Bot | ||
| D150B006 | | D150B006 | ||
+ | |2 | ||
| +14 <!--Bottom delta t from D30T001--> | | +14 <!--Bottom delta t from D30T001--> | ||
Line 74: | Line 76: | ||
| Top | | Top | ||
| D225T007 | | D225T007 | ||
+ | |3 | ||
| -3 <!--Top delta t from D30T001--> | | -3 <!--Top delta t from D30T001--> | ||
|style=" border-bottom: 2px solid black" rowspan="2" | +23 <!--Bottom minus top--> | |style=" border-bottom: 2px solid black" rowspan="2" | +23 <!--Bottom minus top--> | ||
Line 80: | Line 83: | ||
| Bot | | Bot | ||
| D225B008 | | D225B008 | ||
+ | |4 | ||
| +20 <!--Bottom delta t from D30T001--> | | +20 <!--Bottom delta t from D30T001--> | ||
|} | |} | ||
Trigger plugged into patch panel 223A15 : -8 ns | Trigger plugged into patch panel 223A15 : -8 ns |
Revision as of 22:13, 17 August 2016
Procedure
PMT timing relative to D30T001 is measured by splitting a pulse from a pulse generator.
PMT top-bottom difference is the mean time difference of the PMT's using data from the TDC spectrum of a coincidence run with the CF-252 source. The source was placed in the center of all detectors and 150.5 cm above the floor. The trigger detector was located 5.5 cm below the very bottom of the source.
run info
Detectors D30(Red) and D90(yellow):
run #5214 t=1475 seconds
Results
Detector | PMT | sig. cable | Variable index* | relative to D30T001 [ns] | PMT bot - PMT top [ns] | Run # | |
---|---|---|---|---|---|---|---|
angle | color
| ||||||
30 | Red | Top | D30T001 | 1 | +0 (by definition) | +12.5 | r???? |
Bot | D30B002 | 2 | +12.5 | ||||
90 | Yellow | Top | D90T003 | 3 | +1 | +10.5 | |
Bot | D90B004 | 4 | +11.5 | ||||
150 | Blue | Top | D150T005 | 1 | +1 | +13 | r5217 |
Bot | D150B006 | 2 | +14 | ||||
225 | Wood | Top | D225T007 | 3 | -3 | +23 | |
Bot | D225B008 | 4 | +20 |
Trigger plugged into patch panel 223A15 : -8 ns