Difference between revisions of "SeRun 01-11-16"

From New IAC Wiki
Jump to navigation Jump to search
Line 47: Line 47:
 
|-
 
|-
 
| 006 || SeRun_006 || 01/09/16/16:32:55 ||01/09/16/16:34||99.03 ||Na-22 Ser # 129741, 108.5 nCi in Slot F on Detector D  
 
| 006 || SeRun_006 || 01/09/16/16:32:55 ||01/09/16/16:34||99.03 ||Na-22 Ser # 129741, 108.5 nCi in Slot F on Detector D  
 +
|-
 +
| 007 || SeRun_007 || 01/09/16/16:35:29 ||01/09/16/16:36||84.17 ||Ba-133 Ser # 129789, 122.4 nCi in Slot F on Detector D
 
|-
 
|-
 
|}
 
|}
  
 
[[PAA_Selenium#First_Observation_of_Se_lines]]
 
[[PAA_Selenium#First_Observation_of_Se_lines]]

Revision as of 23:37, 9 January 2016

Using the 44 Machine at 7 kW power and 44 meV incident electron energy to produce a bremsstrahlung spectrum with a mean energy of 15 MeV.



SeTarget 01-11-16.png
General Target configurations, Selenium pellets are sandwiched between two Nickel foils


Target Mass (g)
Ni Front 0.0994
Se Shot 1.7842
Ni Rear 0.0948
Target A

Runlist

Target Mass (g)
Ni Front 0.0994
Se Shot 1.7842
Ni Rear 0.0948
Target A
Run Number Filename Start time Stop Time Deadtime corrected Run time (s) comment)
003 SeRun_003 01/08/16/13:57:33 01/09/16/16:21 94612.50 background run
004 SeRun_004 01/09/16/16:24:30 01/09/16/16:26 82.901 Cs-137 Ser # 129792, 92.11 nCi in Slot F on Detector D
005 SeRun_005 01/09/16/16:28:28 01/09/16/16:31 172.099 Co-57 Ser # 129734, 110.9 nCi in Slot F on Detector D (not useful)
006 SeRun_006 01/09/16/16:32:55 01/09/16/16:34 99.03 Na-22 Ser # 129741, 108.5 nCi in Slot F on Detector D
007 SeRun_007 01/09/16/16:35:29 01/09/16/16:36 84.17 Ba-133 Ser # 129789, 122.4 nCi in Slot F on Detector D

PAA_Selenium#First_Observation_of_Se_lines