Difference between revisions of "04-22-2015"
Line 44: | Line 44: | ||
| Fake stop|| Second hit | | Fake stop|| Second hit | ||
|} | |} | ||
− | |||
− | |||
− | |||
− | |||
− | |||
Run 4550 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 2800 Hz. Pu-B source in. | Run 4550 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 2800 Hz. Pu-B source in. | ||
− | [[File:r4550_fake_stop.png | | + | {| cellpadding="2" style="border: 1px solid darkgray;" |
− | + | |- border="0" | |
− | [[File:r4550_det4_up.png | | + | | [[File:r4550_fake_stop.png|340px|Region 1]] |
+ | | [[File:r4550_det4_up.png|340px|Region 2]] | ||
+ | |- align="center" | ||
+ | | Fake stop|| Second hit | ||
+ | |} | ||
Run 4551 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26". | Run 4551 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26". | ||
− | [[File:r4551_fake_stop.png | | + | {| cellpadding="2" style="border: 1px solid darkgray;" |
− | + | |- border="0" | |
− | [[File:r4551_det4_up.png | | + | | [[File:r4551_fake_stop.png|340px|Region 1]] |
− | + | | [[File:r4551_det4_up.png|340px|Region 2]] | |
+ | |- align="center" | ||
+ | | Fake stop|| Second hit | ||
+ | |} | ||
Run 4552 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26". | Run 4552 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26". | ||
− | [[File:r4552_fake_stop.png | | + | {| cellpadding="2" style="border: 1px solid darkgray;" |
− | + | |- border="0" | |
− | [[File:r4552_det4_up.png | | + | | [[File:r4552_fake_stop.png|340px|Region 1]] |
+ | | [[File:r4552_det4_up.png|340px|Region 2]] | ||
+ | |- align="center" | ||
+ | | Fake stop|| Second hit | ||
+ | |} | ||
Run 4553 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 1850 Hz. Pu-Be source in, moved away from the detector by 26". | Run 4553 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 1850 Hz. Pu-Be source in, moved away from the detector by 26". | ||
− | [[File:r4553_fake_stop.png | | + | {| cellpadding="2" style="border: 1px solid darkgray;" |
− | + | |- border="0" | |
− | [[File:r4553_det4_up.png | | + | | [[File:r4553_fake_stop.png|340px|Region 1]] |
+ | | [[File:r4553_det4_up.png|340px|Region 2]] | ||
+ | |- align="center" | ||
+ | | Fake stop|| Second hit | ||
+ | |} | ||
Run 4554 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 625 Hz. Pu-Be source in, moved away from the detector by 52". | Run 4554 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 625 Hz. Pu-Be source in, moved away from the detector by 52". | ||
− | [[File:r4554_fake_stop.png | | + | {| cellpadding="2" style="border: 1px solid darkgray;" |
− | + | |- border="0" | |
− | [[File:r4554_det4_up.png | | + | | [[File:r4554_fake_stop.png|340px|Region 1]] |
+ | | [[File:r4554_det4_up.png|340px|Region 2]] | ||
+ | |- align="center" | ||
+ | | Fake stop|| Second hit | ||
+ | |} | ||
Run 4555 had a discriminator threshold set to 20 mV and the terminators were out. DAQ rate is 650 Hz. Pu-Be source in, moved away from the detector by 52". | Run 4555 had a discriminator threshold set to 20 mV and the terminators were out. DAQ rate is 650 Hz. Pu-Be source in, moved away from the detector by 52". |
Revision as of 19:41, 25 April 2015
Pu-Be source test
PMT detector #4 HV at -1000 Volts
Pu-Be 18 gram source# M1197
Run 4546 had a discriminator threshold set to 80 mV and the terminators were out. Cosmic rays test.
Fake stop | Second hit |
Run 4547 had a discriminator threshold set to 80 mV and the terminators were out. DAQ rate is 100 Hz. Pu-Be source in.
Fake stop | Second hit |
Run 4548 had a discriminator threshold set to 80 mV and the terminators were in. DAQ rate is 100 Hz. Pu-Be source in.
Fake stop | Second hit |
Run 4549 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 2800 Hz. Pu-B source in.
Fake stop | Second hit |
Run 4550 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 2800 Hz. Pu-B source in.
Fake stop | Second hit |
Run 4551 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26".
Fake stop | Second hit |
Run 4552 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26".
Fake stop | Second hit |
Run 4553 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 1850 Hz. Pu-Be source in, moved away from the detector by 26".
Fake stop | Second hit |
Run 4554 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 625 Hz. Pu-Be source in, moved away from the detector by 52".
Fake stop | Second hit |
Run 4555 had a discriminator threshold set to 20 mV and the terminators were out. DAQ rate is 650 Hz. Pu-Be source in, moved away from the detector by 52".
Run 4556 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 1400 Hz. Pu-Be source in, moved away from the detector by 52".
Run 4557 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 1400 Hz. Pu-B source in, moved away from the detector by 52".
PMT detector #4 HV at -1400 Volts
Run 4558 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 4670 Hz. Pu-Be source in, moved away from the detector by 52".
Run 4559 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".
Run 4560 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".
Run 4561 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 200 Hz. Cosmic rays test.
- 1.8 g Pu-Be source should be used next time