04-22-2015: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Kosiolek (talk | contribs)
Kosiolek (talk | contribs)
Line 11: Line 11:
! width="400" | Fit: 5.7 cm/ns; Exp: 6.82 cm/ns
! width="400" | Fit: 5.7 cm/ns; Exp: 6.82 cm/ns
|- border="0"
|- border="0"
| [[File:r4546_fake_stop.png|400px|Region 1]]
| [[File:r4546_fake_stop.png|200px|Region 1]]
| [[File:r4546_det4_up.png|400px|Region 2]]
| [[File:r4546_det4_up.png|200px|Region 2]]
|- align="center"
|- align="center"
| Fake stop|| Second hit
| Fake stop|| Second hit

Revision as of 19:35, 25 April 2015

Pu-Be source test

PMT detector #4 HV at -1000 Volts

Pu-Be 18 gram source# M1197

Run 4546 had a discriminator threshold set to 80 mV and the terminators were out. Cosmic rays test.

Fit: 6.7 cm/ns; Exp: 7.41 cm/ns Fit: 5.7 cm/ns; Exp: 6.82 cm/ns
Region 1 Region 2
Fake stop Second hit

Run 4547 had a discriminator threshold set to 80 mV and the terminators were out. DAQ rate is 100 Hz. Pu-Be source in.

Run 4548 had a discriminator threshold set to 80 mV and the terminators were in. DAQ rate is 100 Hz. Pu-Be source in.


Run 4549 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 2800 Hz. Pu-B source in.


Run 4550 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 2800 Hz. Pu-B source in.

Run 4551 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26".


Run 4552 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26".

Run 4553 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 1850 Hz. Pu-Be source in, moved away from the detector by 26".

Run 4554 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 625 Hz. Pu-Be source in, moved away from the detector by 52".

Run 4555 had a discriminator threshold set to 20 mV and the terminators were out. DAQ rate is 650 Hz. Pu-Be source in, moved away from the detector by 52".


Run 4556 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 1400 Hz. Pu-Be source in, moved away from the detector by 52".

Run 4557 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 1400 Hz. Pu-B source in, moved away from the detector by 52".

PMT detector #4 HV at -1400 Volts

Run 4558 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 4670 Hz. Pu-Be source in, moved away from the detector by 52".

Run 4559 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".

Run 4560 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".

Run 4561 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 200 Hz. Cosmic rays test.


1.8 g Pu-Be source should be used next time