Line 38: Line 38:
|-
|-
| 03/14/13 || 16:46 || S6 SL2 HVB5 || 536 || -750 || 1500 || 3.2 || 3.3 ||
| 03/14/13 || 16:46 || S6 SL2 HVB5 || 536 || -750 || 1500 || 3.2 || 3.3 ||
STB put on. Voltage rise completed, no excess current compared to before STB was installed.
STB put on. Voltage rise completed, no excess current compared to before STB was installed. HV left on over the weekend.
|-
| 03/18/13 || 10:31 || S6 SL2 HVB5 || 536 || -750 || 1500 || 0.48 || 0.57 ||
|-
| 03/18/13 || 15:48 || S6 SL2 HVB5 || 536 || -750 || 1500 || 0.35 || 0.45 || HV left on overnight
|-
| 03/19/13 || 07:29 || S6 SL2 HVB5 || 536 || -750 || 1500 || 0.1 || 0.2 ||

Latest revision as of 13:28, 19 March 2013

Date Time (24h) HV Board ID Guard (V) Field (V) Sense (V) Sense ([math]\displaystyle{ \mu }[/math]A) Field ([math]\displaystyle{ \mu }[/math]A) comments
03/11/13 16:50 S6 SL2 HVB5 50 -50 50 0.000 0.065 Probed traces and pins connected to boots for fields/guard, all are showing voltage.
03/11/13 16:56 S6 SL2 HVB5 536 -750 1500 11.5 11.7 Peaked around 13 [math]\displaystyle{ \mu }[/math]A initially, but is rapidly decreasing after sense wires stabilized at operating voltage. Trip is set to 50 [math]\displaystyle{ \mu }[/math]A, no wires tripped during voltage rise at 5 V/s.
03/11/13 17:11 S6 SL2 HVB5 536 -750 1500 10.7 10.8
03/11/13 17:32 S6 SL2 HVB5 536 -750 1500 10.2 10.3
03/11/13 17:47 S6 SL2 HVB5 536 -750 1500 10.1 10.2 Left HV on overnight
03/12/13 07:34 S6 SL2 HVB5 536 -750 1500 7.5 7.6
03/12/13 10:38 S6 SL2 HVB5 536 -750 1500 7.1 7.2
03/12/13 13:54 S6 SL2 HVB5 536 -750 1500 6.9 7.0
03/12/13 16:55 S6 SL2 HVB5 536 -750 1500 6.8 6.9 Left HV on overnight
03/13/13 07:30 S6 SL2 HVB5 536 -750 1500 5.8 5.9
03/13/13 09:55 S6 SL2 HVB5 536 -750 1500 5.6 5.7
03/13/13 16:45 S6 SL2 HVB5 536 -750 1500 5.3 5.4
03/13/13 17:45 S6 SL2 HVB5 536 -750 1500 5.3 5.4 Left HV on overnight
03/14/13 10:37 S6 SL2 HVB5 536 -750 1500 3.6 3.7
03/14/13 13:43 S6 SL2 HVB5 536 -750 1500 3.4 3.5
03/14/13 16:18 S6 SL2 HVB5 536 -750 1500 3.1 3.2

Turned off HV immediately after reading to put on STB

03/14/13 16:46 S6 SL2 HVB5 536 -750 1500 3.2 3.3

STB put on. Voltage rise completed, no excess current compared to before STB was installed. HV left on over the weekend.

03/18/13 10:31 S6 SL2 HVB5 536 -750 1500 0.48 0.57
03/18/13 15:48 S6 SL2 HVB5 536 -750 1500 0.35 0.45 HV left on overnight
03/19/13 07:29 S6 SL2 HVB5 536 -750 1500 0.1 0.2