Difference between revisions of "Sadiq Thesis"

From New IAC Wiki
Jump to navigation Jump to search
 
(168 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
= Introduction =
 
= Introduction =
  
== Positron ==
 
  
Positron is the antimatter of electron. Positrons have same mass as electron (  <math>511~\frac{keV}{c^2}</math>), carries positive charge, and it is noted as "<math>e^+</math>".
+
== Positron Beam ==
  
Positrons predicted by Paul Dirac in 1928, <ref name="Dirac1928"> The Quantum Theory of the Electron, P. A. M. Dirac, Proc. R. Soc. Lond. A February 1, 1928 117 778 610-624;</ref>, and experimentally observed by Dmitri Skobeltsyn in 1929 and by Carl D. Anderson in 1932 <ref name="e+_discover"> General Chemistry, Taylor and Francis. p. 660. </ref>. Anderson also coined the term positron and he won the Nobel Prize for Physics in 1936.
+
Positrons have many potentials in many discipline of science, like chemistry, physics, material science, surface science, biology and nanoscience <ref name="Chemerisov2009JLabConf"> Chemerisov, S. and Jonah, Charles D., "{Generation of high intensity thermal positron beams using a 20-MeV electron linac}", "AIP Conf.Proc.", "1160", "87-93", "10.1063/1.3232039", "2009" </ref>. There are many different ways to generate positrons, and the main challenge is increasing the intensity (or current) of the positron beam.
  
  
  
 +
== Motivation ==
  
<ref name="name"> BOOK_Gernal, Auther, Month_Year,issue,page </ref>
 
  
== Positron Beamline History ==
+
The nucleon electromagnetic form factors are fundamental  quantities that can be physically interpreted as the charge and magnetic moment of a nucleon in the Beit reference frame where the probe appears to bounce off a target that does not recoil. 
 
+
Conventionally, the nucleon form factors are measured using the Rosenbluth Technique (RT) <ref name="Rosenbluth1950"> M. N. Rosenbluth, Phys. Rev. 79, 615(1950).  </ref>.  The form factor scaling ratio,<math>R=\mu _p G_{Ep} / G_{Mp}</math>, measured using this technique is around unity as shown in the figure below <ref name="Walker1994"> R. C. Walker et al., Phys. Rev. D 49, 5671(1994). </ref>.
=Theory=
+
Since the 1990s, a technique using elastic electron-proton polarization transfer has been developed to measurement this ratio<ref name="Walker1994"> </ref>, <ref name="Arrington2003"> J. Arrington, Phys. Rev. C 68, 034325 (2003). </ref>, <ref name="Walker1989"> R. C. Walker, Ph.D. thesis, California Institute of Technology(1989). </ref>. In this technique, the form factor ratio linearly decreases as the <math>Q^2</math> increases, as shown in the figure below.  
 
 
==Positron creation from Bremsstrahlung==
 
A charge particle passes through a nuclear field generates photon by breamsstrahlung process.  
 
  
 
{| border="1" cellpadding="4"
 
{| border="1" cellpadding="4"
 
|-
 
|-
|[[ File:sadiq_thesis_Brems.png | 200 px   |thumb| Bremsstrahlung. ]]  
+
| [[File:sadiq_thesis_mot_RT_RPT_1.png | 300 px |thumb| FIG. Form factor ratio, obtained by Rosenbluth Technique  (hollow square) and results from Recoil Polarization Technique <ref name="Arrington2003">J. Arrington, Phys. Rev. C 68, (2003) 034325 and arXiv:nucl-ex/0305009. </ref>.
 +
]]  
 
|}
 
|}
  
There are three competing processes that light can interact with matter.  
+
The figure shows that the two techniques disagree at higher value of Q^2.  One proposed reason for this disagreement lies with the Rosenbluth Techqniue's assumption that only one virtual photon is exchanged during the scattering (OPE). Two photon exchange (TPE),depends weakly on <math>Q^2</math> but may become considerable with increasing <math>Q^2</math> and explain the discrepancy  <ref name="Arrington2003"></ref>. The contribution of TPE can be obtained by comparing the ratio of <math>e^+~p</math> to <math>e^-~p</math> ratio. The interference of OPE and TPE can also be studied in the process <math>e^+e^- \rightarrow p\bar p</math>
At low electron volt energy range, light interact with matter via photoelectric effect.
 
As energy of light increases up to to kilo electron volt range, Compton scattering phenomena starts to be more dominant.
 
While the energy of a photon in the photoelectric effect is totally absorbed by an electron, in the Compton effect the energy is partially absorbed. 
 
As energy of light reaches twice rest mass energy of electron, 1.22~MeV, the pair production process starts to become the main interaction process. In this process, photon decays into an electron and positron pair.
 
  
{| border="1" cellpadding="4"
+
why can positron source determine if two photons are exchanged
|-
+
 
|[[  File:sadiq_thesis_PairPro.png  |thumb| Pair production. ]]
+
=Theory=
|}
 
  
 +
==Positron creation from Bremsstrahlung==
  
Discuss other processes an if pair production is dominant process.
 
  
==Positron rate prediction==
 
  
== HRRL Beamline ==
+
When a moving charge particle interacts with the electric field of another charged particle, it can be deflected and releases lost energy in the form of photons. This is known as the Bremsstrahlung process.  The probability of this interaction increases with the atomic number of the material traversed by the incident charged particle.  Figure~\ref{fig"Brem}c show the photon energy distribution when a 12 MeV electron distribution from Figure~\ref{fig"Brem}b interacts with a 1 mm thick Tungsten target.  The number of photons in this example produced decreases as the energy of the produced photon increases.  The Bremsstrahlung photons are also likely to interact with the material.
  
https://wiki.iac.isu.edu/index.php/Beamline_Drawing_2011_J.Ellis
 
  
HRRL beamline layout is given in the figure below, and the item descriptions are given in the table below.
 
  
 
{| border="1" cellpadding="4"
 
{| border="1" cellpadding="4"
 +
|[[  File:sadiq_thesis_Brems.png  | 200 px  ]] [[  File:sadiq_thesis_Brems_ele_Ene.png | 200 px  ]]  [[  File:sadiq_thesis_Brems_photon_Ene.png | 200 px  ]]
 
|-
 
|-
|[[File:HRRL_beamline.png | 600 px |thumb|HRRL beamline layout. ]]
+
| (a)Simulated Bremsstrahlung photon energy right after a tungsten foil(b)Simulated Bremsstrahlung electron energy distribution right before a tungsten foil. (c)Simulated Bremsstrahlung photon energy right after a tungsten foil. 
 
|}
 
|}
  
  
{| border="3" cellpadding="5" cellspacing="0"
+
 
|      Label      || Beam Line Element
+
There are three competing processes that a photon can undergo when interacting with matter.
 +
At electron volt (eV) energies comparable to the electron atomic binding energy, the dominant photon interaction is via photoelectric effect. 
 +
As the photon energy increases up to kilo-electron volt (keV) range, the Compton scattering process starts to be more dominant.
 +
Although the photon is totally absorbed during the photoelectric effect, photons merely lose energy when undergoing Compton scattering. 
 +
As the photon energy reaches twice the rest mass energy of electron, 2 <math>\times</math> 511 keV, pair production begins to happen. Pair production becomes dominant interaction process only for energies above 5 MeV <ref name="Krane"> Introductory Nuclear Physics, K. S. Krane, JOHN WILEY & SONS,1988;</ref>. In this process, a photon interacts with the electric field of the nucleus or the bound electrons and decays into an electron and positron pair.
 +
 +
Insert plot of XCOM Tungsten cross sections showing for each process over the incident photon range available for this experiment.
 +
 
 +
{| border="1" cellpadding="4"
 
|-
 
|-
|       T1      || positron target
+
|[[  File:sadiq_thesis_3pro-in-W.png | 400 px |thumb| Cross section of processes that photons interacts with tungsten. ]]
|-
 
|        T2      || annihilation target
 
|-
 
|       EnS      || energy elit  
 
|-
 
|        FC1, FC2 || Faraday cups
 
|-
 
|       Q1,...Q10|| quadrupoles
 
|-
 
|        D1, D2  || dipoles
 
|-
 
|        NaI      ||  NaI detecotrs
 
|-
 
|        OTR      ||  optical transition radiaiton screen
 
|-
 
|        YAG      || yttrium aluminium garnet screen
 
 
|}
 
|}
  
 +
http://physics.nist.gov/cgi-bin/Xcom/xcom2
 +
 +
 +
The positron and electron pairs are created back to back in the center of mass frame.  In the lab frame, electrons and positrons are boosted forward, as shown in Figure~\ref{fig:annihil}.  The positron and electron carry away the energy from the photon that is in excess of 1.022 MeV.In the center of mass frame, the kinetic energy is equally shared. Photons with an energy above 1.022 MeV in  the bremsstrahlung spectrum of Figure ~\ref{fig:Brem} have the potential to create electron and positron pairs. When the process of annihilation is included in the simulation, Figure~\ref{fig:brem} becomes Figure~\ref{fig:annih}  showing a clear 511 keV peak on top of the bremsstrahlung spectrum. This 511 keV peak represents photon produced when the created positrons, from pair production, annihilates with an atomic electrons inside the tungsten target.
  
 
{| border="1" cellpadding="4"
 
{| border="1" cellpadding="4"
 
|-
 
|-
|[[File:sadiq_thesis_HRRL_sim_setup_T1_UpD_DwD.png | 400 px |thumb|Positron production target (T1), front and back detectors. ]]  
+
|[[   File:sadiq_thesis_PairPro.png   |thumb| Pair production. ]] || [[  File:sadiq_thesis_Brems_photon_Ene_log.png | 200 px   |thumb| Simulated Bremsstrahlung photon energy right after a tungsten foil. ]]
 
|}
 
|}
  
Positron production target is tungsten foil with  1.25 inch (31.75 mm) diameter, 0.04 inch (1.016 mm) thickness, and placed with 45 degree angle leaning forward as shown in figure. Two virtual detectors with 25.4 mm radius located 26.52 mm away from the center of the T1.
 
  
=== Simulation Result ===
 
  
G4beamline simulation of the experiment using electron beam:
 
3160571 electrons on T1 is given in red.
 
2385 positrons escaped downstream of T1 is given in blue.
 
  
  
  incident electron beam position profiles (X,Y) and energy distribution.
+
  Insert a plot of the brehmsstralung photon energy from 12 MeV electron on Tungsten and point out how positrons are generated from this distribution.
 +
What fraction of photons are above 1.022 MeV compared to below.
  
 +
==Positron rate prediction==
  
Positron momentum distributions (Px,Py,Pz,E)
 
  
 +
Positron production target is tungsten foil with  1.25 inch (31.75 mm) diameter, 0.04 inch (1.016 mm) thickness, and placed with 45 degree angle leaning forward as shown in figure. Two virtual detectors with 25.4 mm radius located 26.52 mm away from the center of the T1.
  
electron after the target (Px,Py,Pz,E)
+
=== Simulation Result ===
  
 
+
G4beamline simulation of the experiment using electron beam:
positron distributions right before first quad and the positrons that will be transported
+
3160571 electrons on T1 is given in red.
 
+
2385 positrons escaped downstream of T1 is given in blue.
generate ASCII file to use as positron event generator.  Use root to draw histograms of the ASCII file contents to check them and put them in the wiki.
 
  
  
Line 108: Line 90:
 
||
 
||
 
|[[File:sadiq_thesis_sim_e-_En.png | 400 px  |thumb|Electron beam energy distribution on the T1. ]]  
 
|[[File:sadiq_thesis_sim_e-_En.png | 400 px  |thumb|Electron beam energy distribution on the T1. ]]  
 +
||
 +
[[File:sadiq_thesis_sim_e+_En.png | 400 px  |thumb|Positron energy distribution immediately after T1. ]]
 
|}
 
|}
  
{| border="1" cellpadding="4"
 
|-
 
|[[File:sadiq_thesis_sim_e+_Px.png | 400 px  |thumb|Positron Momentum Projection on x-axis. ]] || [[File:sadiq_thesis_sim_e+_Py.png | 400 px  |thumb|Positron Momentum Projection on y-axis. ]]
 
|-
 
|[[File:sadiq_thesis_sim_e+_Pz.png | 400 px  |thumb|Positron Momentum Projection on z-axis. ]] || [[File:sadiq_thesis_sim_e+_En.png | 400 px  |thumb|Positron energy distribution. ]]
 
|}
 
  
 
{| border="1" cellpadding="4"
 
{| border="1" cellpadding="4"
 
|-
 
|-
|[[File:sadiq_thesis_sim_e-_Px_b.png | 400 px  |thumb|Electron Momentum Projection on x-axis after T1. ]] || [[File:sadiq_thesis_sim_e-_Py_b.png | 400 px  |thumb|Electron Momentum Projection on y-axis after T1. ]]
+
| [[File:sadiq_thesis_sim_e-_En_b.png | 400 px  |thumb|Electron energy distribution after T1. ]]
|-
 
|[[File:sadiq_thesis_sim_e-_Pz_b.png | 400 px  |thumb|Electron Momentum Projection on z-axis after T1. ]] || [[File:sadiq_thesis_sim_e-_En_b.png | 400 px  |thumb|Electron energy distribution after T1. ]]
 
 
|}
 
|}
  
 
=Apparatus=
 
=Apparatus=
 +
 +
== HRRL Beamline ==
 +
 +
https://wiki.iac.isu.edu/index.php/Beamline_Drawing_2011_J.Ellis
  
 
The HRRL (High Repetition Rate Linac) ia a 16~MeV S-band  linac located at the Beam Lab of the Department of the Physics, Idaho State University. The HRRL linac structure was upgraded beyond the capabilities of a typical medical linac so it can achieve a repetition rate of 1~kHz.  
 
The HRRL (High Repetition Rate Linac) ia a 16~MeV S-band  linac located at the Beam Lab of the Department of the Physics, Idaho State University. The HRRL linac structure was upgraded beyond the capabilities of a typical medical linac so it can achieve a repetition rate of 1~kHz.  
Line 142: Line 122:
 
|-
 
|-
 
|  macro pulse length|| ns || >50  
 
|  macro pulse length|| ns || >50  
 +
|}
 +
 +
 +
 +
HRRL beamline layout is given in the figure below, and the item descriptions are given in the table below.
 +
 +
{| border="1" cellpadding="4"
 +
|-
 +
|[[File:HRRL_beamline.png | 600 px  |thumb|HRRL beamline layout. ]]
 +
|}
 +
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|      Label      || Beamline Element
 +
|-
 +
|        T1      || positron target
 +
|-
 +
|        T2      || annihilation target
 +
|-
 +
|        EnS      || energy slit 
 +
|-
 +
|        FC1, FC2 || Faraday cups
 +
|-
 +
|        Q1,...Q10|| quadrupoles
 +
|-
 +
|        D1, D2  || dipoles
 +
|-
 +
|        NaI      ||  NaI detecotrs
 +
|-
 +
|        OTR      ||  optical transition radiation screen
 +
|-
 +
|        YAG      || yttrium aluminium garnet screen
 +
|}
 +
 +
 +
{| border="1" cellpadding="4"
 +
|-
 +
|[[File:sadiq_thesis_HRRL_sim_setup_T1_UpD_DwD2.png | 400 px  |thumb|T1: Positron production target; DUPT1: upstream detector; DDNT1: down stream (DDNT1); DT1: detector right after T1. ]]
 
|}
 
|}
  
Line 295: Line 313:
 
Digital images from the JAI camera were extracted in a matrix format in order to take projections on both axes and perform a Gaussian fit. The observed image profiles were not well described by a single Gaussian distribution.  The profiles may be described using a Lorentzian distribution, however, the rms of the Lorentzian function is not defined. The super Gaussian distribution seems to be the best option~<ref name="sup-Gau"> F.J. Decker, SLAC-PUB-6684, Sep, 1994. </ref>, because rms values may be directly extracted.
 
Digital images from the JAI camera were extracted in a matrix format in order to take projections on both axes and perform a Gaussian fit. The observed image profiles were not well described by a single Gaussian distribution.  The profiles may be described using a Lorentzian distribution, however, the rms of the Lorentzian function is not defined. The super Gaussian distribution seems to be the best option~<ref name="sup-Gau"> F.J. Decker, SLAC-PUB-6684, Sep, 1994. </ref>, because rms values may be directly extracted.
  
Fig.~\ref{par-fit}  shows the square of the rms (<math>\sigma^2_{s}</math>) ''vs'' ''k_1L'' for ''x'' (horizontal) and ''y'' (vertical) beam projections along with the parabolic fits using Eq.~\ref{par_fit}. The emittances and Twiss parameters from these fits are summarized in Table~\ref{results}.  An automatic MATLAB based emittance measurement tool is under development~\cite{emit-mat}.
+
Fig.~\ref{par-fit}  shows the square of the rms (<math>\sigma^2_{s}</math>) ''vs'' ''k_1L'' for ''x'' (horizontal) and ''y'' (vertical) beam projections along with the parabolic fits using Eq.~\ref{par_fit}. The emittances and Twiss parameters from these fits are summarized in Table~\ref{results}.   
 +
 
  
<ref name="emit-mat"> C.F. Eckman ''et'' ''al''., in ''Proc''. ''IPAC2012'', New Orleans, USA. </ref>.
 
  
  
Line 343: Line 361:
 
The beam energy spread does not follow Gaussian distribution, but the overlapping of two skewed Gaussian found to be the best description of beam energy profile [[Media:Beam_Distributions_Beyond_RMS.pdf]].
 
The beam energy spread does not follow Gaussian distribution, but the overlapping of two skewed Gaussian found to be the best description of beam energy profile [[Media:Beam_Distributions_Beyond_RMS.pdf]].
  
Amplitude = 2.13894, mean = 12.07181, sigma_L = 4.46986, sigma_R = 1.20046
+
 
 +
 
  
 
Sigma = 2.83516, Es = -0.57658  
 
Sigma = 2.83516, Es = -0.57658  
Line 349: Line 368:
 
rms = 2.56472, skew = -0.94853  
 
rms = 2.56472, skew = -0.94853  
  
 
Amplitude2 = 10.88318, mean2 = 12.32332, sigma_L2 = 0.69709, sigma_R2 = 0.45170
 
  
 
Sigma2 = 0.57440, Es2 = -0.21360  
 
Sigma2 = 0.57440, Es2 = -0.21360  
Line 356: Line 373:
 
rms2 = 0.56719, skew2 = -0.34231
 
rms2 = 0.56719, skew2 = -0.34231
  
=== Current, rep-rate===
 
  
===(Appendix) Radiation Footprint===
+
{|border="2" colspan = "20"
 +
|-
 +
| parameter  ||  Notation            ||  First Gaussian  || Second Gaussian
 +
|-
 +
| amplitude  || A                    ||  2.13894  ||  10.88318
 +
|-
 +
| mean || <math>\mu</math>            ||  12.07181  || 12.32332
 +
|-
 +
| sigma left || <math>\sigma_L</math> ||  4.46986  ||  0.69709
 +
|-
 +
| sigma right|| <math>\sigma_R</math> ||  1.20046  ||  0.45170
 +
|-
 +
|}
  
 
==Positron detection==
 
==Positron detection==
Line 383: Line 411:
  
 
=Data Analysis=
 
=Data Analysis=
 +
 +
[[Back of the envelope calculation for e+/e- ratio]]
 +
  
 
==Signal extraction==
 
==Signal extraction==
Line 457: Line 488:
 
|}
 
|}
  
===== Electron Electron Rate Calculation for Run 3735 =====
+
==== Electron Electron Rate Calculation for Run 3735 ====
  
 
Total number of electrons in this run is <math>N_{e^-}= (2.99 \pm 0.45 ) \times 10^{16}.</math>
 
Total number of electrons in this run is <math>N_{e^-}= (2.99 \pm 0.45 ) \times 10^{16}.</math>
Line 545: Line 576:
 
| Energy (MeV)|| Positron to Electron Ratio
 
| Energy (MeV)|| Positron to Electron Ratio
 
|-
 
|-
| 1 || <math>{R}_{1MeV} = ( 1.9 \pm 0.9 )\times 10^{-16} </math>
+
| 1 || <math> ( 1.9 \pm 0.9 )\times 10^{-16} </math>
 
|-
 
|-
| 2 || <math>{R}_{2MeV} = ( 6.9 \pm 2.4 )\times 10^{-16} </math>
+
| 2 || <math> ( 6.9 \pm 2.4 )\times 10^{-16} </math>
 
|-
 
|-
| 3 || <math>{R}_{3MeV} = ( 8.25 \pm 0.96 )\times 10^{-15}</math>
+
| 3 || <math> ( 8.3 \pm 1.0 )\times 10^{-15}</math>
 
|-
 
|-
| 4 || <math>{R}_{4MeV} = ( 4.2 \pm 0.8 )\times 10^{-15}</math>  
+
| 4 || <math> ( 4.2 \pm 0.8 )\times 10^{-15}</math>  
 
|-
 
|-
| 5 || <math>{R}_{5MeV} = ( 6.2  \pm  1.6 )\times 10^{-16}</math>
+
| 5 || <math> ( 6.2  \pm  1.6 )\times 10^{-16}</math>
 
|-
 
|-
 
|}
 
|}
Line 573: Line 604:
  
 
Error on positron beam rate is derived from: <math>\sqrt{\frac{positron~rate}{run~time}}</math>
 
Error on positron beam rate is derived from: <math>\sqrt{\frac{positron~rate}{run~time}}</math>
 +
 +
====Annihilation target angle====
 +
 +
Use simulation to determine how sensitive annihilation of positrons is to angle.
 +
 +
What is the dependence of the annihilation target angle with the probability of a positron annihilating in the target and producing a photon that is detected by the NaI detector,
 +
 +
 +
What is the distribution of 511s as a function of angle phi when theta is 90 degrees?  Are they uniformly produced?
 +
 +
====Energy cut systematics====
 +
 +
How does the positron production efficiency change when you change the range of the 511 cut.
  
 
==Efficiency measurement==
 
==Efficiency measurement==
  
 
===acceptance, quad collection efficiency, ===
 
===acceptance, quad collection efficiency, ===
 +
 +
 +
= Simulation =
 +
 +
[[July2012PosSimulation]]
 +
 +
A simulation was performed using the package G4beamline(ref Muons inc) to study the processes of position generation and transportation. "G4beamline is a particle tracking and simulation program based on the Geant4 (refernce G4)  toolkit that is specifically designed to easily simulate beamlines and other systems using single-particle tracking."  Since the ratio of e+/e- during the positron generation process is very low (on the order of 0.001) and the positron beam loss during the transportation is large, it was necessary to divide whole process into 5 steps.  A new beam event generator is created based on the results of the previous step in the simulation. 
 +
 +
The first step generates electrons according to a measurement made of the accelerator that was used in the experiment.  Electrons are transported to T1 in vacuum and as a result the interactions of the electron with T1 produce positrons. The second step is the transportation of the positrons generated at T1 to the entrance of first dipole magnet. The third step is the transportation of the positrons from the entrance of the first dipole magnet to the end of the second dipole. The fourth step is the transportation of the beam from the exit of the second dipole to the T2 target. The fifth step is the positron beam interaction with T2 and detection of the resulting 511 keV photons.
 +
 +
== Step 1 - The Electron Beam Generation and Transpiration to T1 ==
 +
 +
In this step, an electron beam is generated from the experimental measure electron beam parameters. The Twis parameters described in the earlier chapter used electron generated the beam. The energy distribution is of the beam is measured and shown in the Fig.~\ref{fig:sim-ele-En}. The blue dots are measurements and red line are the fit composed of two skewed Gaussian distributions. The fit parameters are given in the Table~\ref{tab:sim-skew-Gau}
 +
 +
 +
[[File:hrrl_17May2012_12MeV_En_Spread2.png | 400 px]]
 +
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  || Amplitude || Mean (MeV) || <math>\sigma _L</math> ||<math>\sigma _R</math> 
 +
|-
 +
| First Gaussian || 2.14 || 12.07 || 4.47 || 1.20
 +
|-
 +
| Second Gaussian || 10.88 || 12.32 || 0.70 || 0.45
 +
 +
|}
 +
 +
Series of virtual detectors are placed along the beamline to sample the beam. As an example, in the Fig.~\ref{fig:sim-T1-3det} shown are three detectors and the T1. The electron beam is observed at DUPT1 (Detector 25.52 mm UPstram of T1) and positrons (or electrons and photons) generated during the interaction of electron beam with T1 are observed at DT1 (Detector of T1) and DDNT1 (Detector DowN 25.52 mm stream of T1). In the Fig.~\ref{fig:sim-ele-pos}, the incoming electron beam (observed at DUPT1) energy distribution (red) and positrons generated by this electron beam (observed at DDNT1) is shown in blue.
 +
 +
{| border="1" cellpadding="4"
 +
|-
 +
|[[File:sadiq_thesis_HRRL_sim_setup_T1_UpD_DwD2.png | 400 px  |thumb|T1: Positron production target; DUPT1: upstream detector; DDNT1: down stream (DDNT1); DT1: detector right after T1. ]]
 +
|}
 +
 +
 +
=== Results  ===
 +
 +
====DDNT1====
 +
 +
13,799,743,900 electrons were shot on T1 and resulted positron beam observed at DDNT1 is as shown below Figures.
 +
 +
[[File:STSimS1_En_DDNT1_e+.png | 400 px]]
 +
 +
[[File:STSimS1_X_DDNT1.png | 400 px]]
 +
 +
[[File:STSimS1_Y_DDNT1.png | 400 px]]
 +
 +
[[File:STSimS1_XP_DDNT1.png | 400 px]]
 +
 +
[[File:STSimS1_YP_DDNT1.png | 400 px]]
 +
 +
[[File:STSimS1_XY_DDNT1.png | 400 px]]
 +
 +
[[File:STSimS1_XY_DDNT1_zoom.png | 400 px]]
 +
 +
The Y-position distribution of the beam shown in Figure ~\ref{sim-DDNT1-y-vs-x} has a sharp drop in the region between -25.8 mm and -27.2 mm that corresponds to the boundary of the target T1.  Figure ~\ref{sim-DDNT1-T1-geo} shows the geometry of the target T1 and the sensitive detector DDNT1.  If the target size was increased, it would eventually intersected the detector DDNT1 at a distance of 25.8 mm from the beam center.  A 1.4 mm wide stripe of low counts is visible on DDNT1 that is a result of the target's thickness of 1.016 mm and the 45 degree angle of intersection.  (<math>1.016 \sqrt{2}=1.44</math>).  The edge of the target does not produce many positrons compared to the face of the target, and as a result you see the stripe.
 +
 +
As shown in figures ~\ref{sim-DDNT1-theta-vs-y} and ~\ref{sim-DDNT1-theta-vs-y-zoom} (zoomed figure) the positron distribution decrease occures at <math>\theta = 45^o</math>.  Positrons are emitted from both the downstream and upstream side of the target.  As shown in the figure, positrons from the downstream side of the target intersect the detector at angles below 45 degrees while positrons from the upstream side of the target begin to hit the detector at angles beyond 45 degrees.  The 1.4 mm gap represents the transition of positrons between these two extremes. 
 +
 +
 +
[[File:hrrl_pos_sim_pos_sharp_drop_geometry2.png | 400 px]]
 +
 +
 +
[[File:STSimS1_YYP_DDNT1.png | 400 px]]
 +
 +
[[File:STSimS1_YYP_DDNT1_zoom.png | 400 px]]
 +
 +
====DQ4 and DD1====
 +
 +
Resulted positron beam on DQ1 and DD1 are shown in below Figures.
 +
 +
[[File:STSimS1_En_DQ4_e+.png | 400 px]]
 +
 +
[[File:STSimS1_En_DD1_e+.png | 400 px]]
 +
 +
== Step 2 - Transportation of the The Positron Beam after T1 to The Entrance of The First Dipole==
 +
In this step, the positrons generated in the first step divided into 1~keV/c momentum bins and each bin is sampled individually since the momentum of the positrons related to their divergence. Multiple beams with individual weights generated at downstream T1 detector DDNT1 and transported to entrance of the D1. Virtual detectors are placed at the entrance of Q4 and entrance of D1 to track positrons and generate beam for next step as shown in the Fig~\ref{fig:Sim-s1-setup}.
 +
 +
[[File:STSimSetupS2.png | 400 px]]
  
 
=Conclusion=
 
=Conclusion=
Line 628: Line 751:
 
  29        0.364    14.2850
 
  29        0.364    14.2850
 
  30        0.364    14.6469
 
  30        0.364    14.6469
 +
 +
==2. Radiation Footprint==
  
 
=References=
 
=References=
 
   
 
   
 
<references/>
 
<references/>

Latest revision as of 16:24, 7 May 2013

Introduction

Positron Beam

Positrons have many potentials in many discipline of science, like chemistry, physics, material science, surface science, biology and nanoscience <ref name="Chemerisov2009JLabConf"> Chemerisov, S. and Jonah, Charles D., "{Generation of high intensity thermal positron beams using a 20-MeV electron linac}", "AIP Conf.Proc.", "1160", "87-93", "10.1063/1.3232039", "2009" </ref>. There are many different ways to generate positrons, and the main challenge is increasing the intensity (or current) of the positron beam.


Motivation

The nucleon electromagnetic form factors are fundamental quantities that can be physically interpreted as the charge and magnetic moment of a nucleon in the Beit reference frame where the probe appears to bounce off a target that does not recoil. Conventionally, the nucleon form factors are measured using the Rosenbluth Technique (RT) <ref name="Rosenbluth1950"> M. N. Rosenbluth, Phys. Rev. 79, 615(1950). </ref>. The form factor scaling ratio,[math]R=\mu _p G_{Ep} / G_{Mp}[/math], measured using this technique is around unity as shown in the figure below <ref name="Walker1994"> R. C. Walker et al., Phys. Rev. D 49, 5671(1994). </ref>. Since the 1990s, a technique using elastic electron-proton polarization transfer has been developed to measurement this ratio<ref name="Walker1994"> </ref>, <ref name="Arrington2003"> J. Arrington, Phys. Rev. C 68, 034325 (2003). </ref>, <ref name="Walker1989"> R. C. Walker, Ph.D. thesis, California Institute of Technology(1989). </ref>. In this technique, the form factor ratio linearly decreases as the [math]Q^2[/math] increases, as shown in the figure below.

FIG. Form factor ratio, obtained by Rosenbluth Technique (hollow square) and results from Recoil Polarization Technique <ref name="Arrington2003">J. Arrington, Phys. Rev. C 68, (2003) 034325 and arXiv:nucl-ex/0305009. </ref>.

The figure shows that the two techniques disagree at higher value of Q^2. One proposed reason for this disagreement lies with the Rosenbluth Techqniue's assumption that only one virtual photon is exchanged during the scattering (OPE). Two photon exchange (TPE),depends weakly on [math]Q^2[/math] but may become considerable with increasing [math]Q^2[/math] and explain the discrepancy <ref name="Arrington2003"></ref>. The contribution of TPE can be obtained by comparing the ratio of [math]e^+~p[/math] to [math]e^-~p[/math] ratio. The interference of OPE and TPE can also be studied in the process [math]e^+e^- \rightarrow p\bar p[/math]

why can positron source determine if two photons are exchanged

Theory

Positron creation from Bremsstrahlung

When a moving charge particle interacts with the electric field of another charged particle, it can be deflected and releases lost energy in the form of photons. This is known as the Bremsstrahlung process. The probability of this interaction increases with the atomic number of the material traversed by the incident charged particle. Figure~\ref{fig"Brem}c show the photon energy distribution when a 12 MeV electron distribution from Figure~\ref{fig"Brem}b interacts with a 1 mm thick Tungsten target. The number of photons in this example produced decreases as the energy of the produced photon increases. The Bremsstrahlung photons are also likely to interact with the material.


Sadiq thesis Brems.png Sadiq thesis Brems ele Ene.png Sadiq thesis Brems photon Ene.png
(a)Simulated Bremsstrahlung photon energy right after a tungsten foil. (b)Simulated Bremsstrahlung electron energy distribution right before a tungsten foil. (c)Simulated Bremsstrahlung photon energy right after a tungsten foil.


There are three competing processes that a photon can undergo when interacting with matter. At electron volt (eV) energies comparable to the electron atomic binding energy, the dominant photon interaction is via photoelectric effect. As the photon energy increases up to kilo-electron volt (keV) range, the Compton scattering process starts to be more dominant. Although the photon is totally absorbed during the photoelectric effect, photons merely lose energy when undergoing Compton scattering. As the photon energy reaches twice the rest mass energy of electron, 2 [math]\times[/math] 511 keV, pair production begins to happen. Pair production becomes dominant interaction process only for energies above 5 MeV <ref name="Krane"> Introductory Nuclear Physics, K. S. Krane, JOHN WILEY & SONS,1988;</ref>. In this process, a photon interacts with the electric field of the nucleus or the bound electrons and decays into an electron and positron pair.

Insert plot of XCOM Tungsten cross sections showing for each process over the incident photon range available for this experiment.
Cross section of processes that photons interacts with tungsten.

http://physics.nist.gov/cgi-bin/Xcom/xcom2


The positron and electron pairs are created back to back in the center of mass frame. In the lab frame, electrons and positrons are boosted forward, as shown in Figure~\ref{fig:annihil}. The positron and electron carry away the energy from the photon that is in excess of 1.022 MeV.In the center of mass frame, the kinetic energy is equally shared. Photons with an energy above 1.022 MeV in the bremsstrahlung spectrum of Figure ~\ref{fig:Brem} have the potential to create electron and positron pairs. When the process of annihilation is included in the simulation, Figure~\ref{fig:brem} becomes Figure~\ref{fig:annih} showing a clear 511 keV peak on top of the bremsstrahlung spectrum. This 511 keV peak represents photon produced when the created positrons, from pair production, annihilates with an atomic electrons inside the tungsten target.

Pair production.
Simulated Bremsstrahlung photon energy right after a tungsten foil.



Insert a plot of the brehmsstralung photon energy from 12 MeV electron on Tungsten and point out how positrons are generated from this distribution.
What fraction of photons are above 1.022 MeV compared to below.

Positron rate prediction

Positron production target is tungsten foil with 1.25 inch (31.75 mm) diameter, 0.04 inch (1.016 mm) thickness, and placed with 45 degree angle leaning forward as shown in figure. Two virtual detectors with 25.4 mm radius located 26.52 mm away from the center of the T1.

Simulation Result

G4beamline simulation of the experiment using electron beam: 3160571 electrons on T1 is given in red. 2385 positrons escaped downstream of T1 is given in blue.


Electron beam spacial distribution on the T1.
Electron beam energy distribution on the T1.
Positron energy distribution immediately after T1.


Electron energy distribution after T1.

Apparatus

HRRL Beamline

https://wiki.iac.isu.edu/index.php/Beamline_Drawing_2011_J.Ellis

The HRRL (High Repetition Rate Linac) ia a 16~MeV S-band linac located at the Beam Lab of the Department of the Physics, Idaho State University. The HRRL linac structure was upgraded beyond the capabilities of a typical medical linac so it can achieve a repetition rate of 1~kHz.

Some parameters of the HRRL is given by:

Parameter Unit Value
maximum energy MeV 16
peak current mA 100
repetition rate Hz 300
absolute energy spread MeV 2-4
macro pulse length ns >50


HRRL beamline layout is given in the figure below, and the item descriptions are given in the table below.

HRRL beamline layout.


Label Beamline Element
T1 positron target
T2 annihilation target
EnS energy slit
FC1, FC2 Faraday cups
Q1,...Q10 quadrupoles
D1, D2 dipoles
NaI NaI detecotrs
OTR optical transition radiation screen
YAG yttrium aluminium garnet screen


T1: Positron production target; DUPT1: upstream detector; DDNT1: down stream (DDNT1); DT1: detector right after T1.

Beam properties

Emittance Measurement

Emittance is an important parameter in accelerator physics. If emittance with twiss parameters are given at the exit of the gun, we will be able to calculate beam size and divergence any point after the exit of the gun. Knowing the beam size and beam divergence on the positron target will greatly help us study the process of creating positron. Emittance with twiss parameters are also key parameters for any accelerator simulations. Also, energy and energy spread of the beam will be measured in the emittance measurement.

What is Emittance

Fig.1 Phase space ellipse <ref name="MConte08"></ref>.

In accelerator physics, Cartesian coordinate system was used to describe motion of the accelerated particles. Usually the z-axis of Cartesian coordinate system is set to be along the electron beam line as longitudinal beam direction. X-axis is set to be horizontal and perpendicular to the longitudinal direction, as one of the transverse beam direction. Y-axis is set to be vertical and perpendicular to the longitudinal direction, as another transverse beam direction.

For the convenience of representation, we use [math]z[/math] to represent our transverse coordinates, while discussing emittance. And we would like to express longitudinal beam direction with [math]s[/math]. Our transverse beam profile changes along the beam line, it makes [math]z[/math] is function of [math]s[/math], [math]z~(s)[/math]. The angle of a accelerated charge regarding the designed orbit can be defined as:

[math]z'=\frac{dz}{ds}[/math]

If we plot [math]z[/math] vs. [math]z'[/math], we will get an ellipse. The area of the ellipse is an invariant, which is called Courant-Snyder invariant. The transverse emittance [math]\epsilon[/math] of the beam is defined to be the area of the ellipse, which contains 90% of the particles <ref name="MConte08"> M. Conte and W. W. MacKay, “An Introduction To The Physics Of Particle Accelera tors”, World Scientifc, Singapore, 2008, 2nd Edition, pp. 257-330. </ref>.

By changing quadrupole magnetic field strength [math]k[/math], we can change beam sizes [math]\sigma_{x,y}[/math] on the screen. We make projection to the x, y axes, then fit them with Gaussian fittings to extract rms beam sizes, then plot vs [math]\sigma_{x,y}[/math] vs [math]k_{1}L[/math]. By Fitting a parabola we can find constants [math]A[/math],[math]B[/math], and [math]C[/math], and get emittances.

Emittance Measurements with an OTR

A beam emittance measurement of the HRRL was performed at Idaho State University's IAC with YAG (Yttrium Aluminium Garnet) was performed. Due to the high sensitivity of YAG, the beam image was saturated and beam spot pears rather big. Comparison study shows that for same beam YAG screen shows bigger beam size than Optical Transition Radiation (OTR) screen. An OTR based viewer was installed to allow measurements at the high electron currents available using the HRRL.

The OTR screen is 10 [math]\mu m[/math] thick aluminium. Beam images were taken with digital CCD camera, a MATLAB tool were used to extract beamsize and emittance.

The visible light from the OTR based viewer is produced when a relativistic electron beam crosses the boundary of two mediums with different dielectric constants. Visible radiation is emitted at an angle of 90 degree with respect to the incident beam direction<ref name="OTR"> Tech. Rep., B. Gitter, Los Angeles, USA (1992). </ref> when the electron beam intersects the OTR target at a 45 degree angle. These backward-emitted photons are observed using a digital camera and can be used to measure the shape and intensity of the electron beam based on the OTR distribution.


Quadrupole Scanning Method
Fig. Simplified setup configuration for HRRL beamline at 2011 March measurement.


Fig. on the right illustrates the apparatus used to measure the emittance using the quadrupole scanning method. A quadrupole is positioned at the exit of the linac to focus or de-focus the beam as observed on a downstream view screen. The 3.1 m distance between the quadrupole and the screen was chosen in order to minimize chromatic effects and to satisfy the thin lens approximation.


Assuming the thin lens approximation, [math]\sqrt{k_1}L \lt \lt 1[/math], is satisfied, the transfer matrix of a quadrupole magnet may be expressed as


[math] \mathrm{\mathbf{Q}}=\Bigl(\begin{array}{cc} 1 & 0\\ -k_{1}L & 1 \end{array}\Bigr)=\Bigl(\begin{array}{cc} 1 & 0\\ -\frac{1}{f} & 1 \end{array}\Bigr), [/math]



where [math] k_{1}[/math] is the quadrupole strength, [math]L[/math] is the length of quadrupole, and [math]f[/math] is the focal length. A matrix representing the drift space between the quadrupole and screen is given by

[math] \mathbf{\mathbf{S}}=\Bigl(\begin{array}{cc} 1 & l\\ 0 & 1 \end{array}\Bigr), [/math]

where [math]l[/math] is the distance between the scanning quadrupole and the screen. The transfer matrix of the scanning region is given by the matrix product [math]\mathbf{SQ}[/math]. In the horizontal plane, the beam matrix at the screen ([math]\mathbf{\sigma_{s}}[/math]) is related to the beam matrix of the quadrupole ([math]\mathbf{\sigma_{q}}[/math]) using the similarity transformation

[math] \mathbf{\mathbf{\sigma_{s}=M\mathrm{\mathbf{\mathbf{\sigma_{q}}}}}M}^{\mathrm{T}}. [/math]

where the [math]\mathbf{\sigma_{s}}[/math] and [math]\mathbf{\sigma_{q}}[/math] are defined as <ref name="SYLee"> Accelerator Physics, S.Y. Lee, (Singapore: World Scientific, 2004), 61. </ref>


[math] \mathbf{\mathbf{\sigma_{s,{x}}=}}\Bigl(\begin{array}{cc} \sigma_{{s},x}^{2} & \sigma_{{s},xx'} \\ \sigma_{{s},xx'} & \sigma_{{s},x'}^{2} \end{array}\Bigr) ,\; \mathbf{\mathbf{\sigma_{q,{x}}}}=\Bigl(\begin{array}{cc} \sigma_{{q},x}^{2} & \sigma_{{q},xx'}\\ \sigma_{{q},xx'} & \sigma_{{q},x'}^{2} \end{array}\Bigr). [/math]


By defining the new parameters <ref name="quad-scan"> D.F.G. Benedetti, et al., Tech. Rep., DAFNE Tech. Not., Frascati, Italy (2005). </ref>, [math]A \equiv \sigma_{11},~B \equiv \frac{\sigma_{12}}{\sigma_{11}},~C \equiv \frac{\epsilon_{x}^{2}}{\sigma_{11}}[/math]


[math] A \equiv l^2\sigma_{{q},x}^{2},~B \equiv \frac{1}{l} + \frac{\sigma_{{q},xx'}}{\sigma_{{q},x}^{2}},~C \equiv l^2\frac{\epsilon_{x}^{2}}{\sigma_{{q},x}^{2}}, [/math]

the matrix element [math]\sigma_{{s},x}^{2}[/math], the square of the rms beam size at the screen, may be expressed as a parabolic function of the product of [math]k_1[/math] and [math]L[/math]

[math] \sigma_{{s},x}^{2}=A(k_{1}L)^{2}-2AB(k_{1}L)+(C+AB^{2}). [/math]

The emittance measurement was performed by changing the quadrupole current, which changes [math]k_{1}L[/math], and measuring the corresponding beam image on the view screen. The measured two-dimensional beam image was projected along the image's abscissa and ordinate axes. A Gaussian fitting function is used on each projection to determine the rms value, [math]\sigma_{s}[/math] in Eq.~(\ref{par_fit}). Measurements of [math]\sigma_{s}[/math] for several quadrupole currents ([math]k_{1}L[/math]) is then fit using the parabolic function in Eq.~(\ref{par_fit}) to determine the constants [math]A[/math], [math]B[/math], and [math]C[/math]. The emittance ([math]\epsilon[/math]) and the Twiss parameters ([math]\alpha[/math] and [math]\beta[/math]) can be found using Eq.~(\ref{emit-relation}).


[math] \epsilon=\frac{\sqrt{AC}}{l^2},~\beta=\sqrt{\frac{A}{C}},~\alpha=\sqrt{\frac{A}{C}}(B+\frac{1}{l}). [/math]



The OTR Imaging System

The OTR target is 10 [math]\mu[/math]m thick aluminum foil with a 1.25 inch diameter. The OTR is emitted in a cone shape with the maximum intensity at an angle of [math]1/\gamma[/math] with respect to the reflecting angle of the electron beam<ref name="OTR"></ref>. Three lenses, 2 inches in diameter, are used for the imaging system to avoid optical distortion at lower electron energies. The focal lengths and position of the lenses are shown in Fig. on the right. The camera used was a JAI CV-A10GE digital camera with a 767 by 576 pixel area. The camera images were taken by triggering the camera synchronously with the electron gun.


Fig. HRRL beamline: Optical lenses lay out for optical cage system.
Fig. HRRL beamline: Cage system for camera. Camera is at the bottom.
Quadrupole Scanning

The quadrupole current is changed to alter the strength and direction of the quadrupole magnetic field such that a measurable change in the beam shape is seen by the OTR system. Initially, the beam was steered by the quadrupole indicating that the beam was not entering along the quadrupole's central axis. Several magnetic elements upstream of this quadrupole were adjusted to align the incident electron beam with the quadrupole's central axis. First, the beam current observed by a Faraday cup located at the end of beam line was maximized using upstream steering coils within the linac nearest the gun. Second, the first solenoid nearest the linac gun was used to focus the electron beam on the OTR screen. Steering coils were adjusted to maximize the beam current to the Faraday cup and minimize the deflection of the beam by the solenoid first then by the quadrupole. A second solenoid and the last steering magnet, both near the exit of the linac, were used in the final step to optimize the beam spot size on the OTR target and maximize the Faraday cup current. A configuration was found that minimized the electron beam deflection when the quadrupole current was altered during the emittance measurements.

The emittance measurement was performed using an electron beam energy of 15~MeV and a 200~ns long, 40~mA, macro pulse peak current. The current in the first quadrupole after the exit of the linac was changed from $-$~5~A to 5~A with an increment of 0.2~A. Seven measurements were taken at each current step in order to determine the average beam width and the variance. Background measurements were taken by turning the linac's electron gun off while keep the RF on. Background image and beam images before and after background subtraction are shown in Fig.~\ref{bg}. A small dark current is visible in Fig.~\ref{bg}b that is known to be generated when electrons are pulled off the cavity wall and accelerated.

(a) a beam with the dark current and background noise.
(b) a background image.
(c) a beam image when dark background was subtracted.

In Fig. below, the images of the electron shown for 0, +1 and +2 Q1 coildcurrents.

Fig. OTR image of 0 Amp Q1 coil current.
Fig. OTR image of +1 Amp Q1 coil current.
Fig. OTR image of +2 Amp Q1 coil current.

The electron beam energy was measured using a dipole magnet downstream of the quadrupole used for the emittance measurements. Prior to energizing the dipole, the electron micro-pulse bunch charge passing through the dipole was measured using a Faraday cup located approximately 50~cm downstream of the OTR screen. The dipole current was adjusted until a maximum beam current was observed on another Faraday cup located just after the 45 degree exit port of the dipole. A magnetic field map of the dipole suggests that the electron beam energy was 15~[math]\pm[/math]~1.6~MeV. Future emittance measurements are planned to cover the entire energy range of the linac.

Data Analysis and Results

Images from the JAI camera were calibrated using the OTR target frame. An LED was used to illuminate the OTR aluminum frame that has a known inner diameter of 31.75~mm. Image processing software was used to inscribe a circle on the image to measure the circular OTR inner frame in units of pixels. The scaling factor can be obtained by dividing this length with the number of pixels observed. The result is a horizontal scaling factor of 0.04327~[math]\pm[/math]~0.00016~mm/pixel and vertical scaling factor of 0.04204~[math]\pm[/math]~0.00018~mm/pixel. Digital images from the JAI camera were extracted in a matrix format in order to take projections on both axes and perform a Gaussian fit. The observed image profiles were not well described by a single Gaussian distribution. The profiles may be described using a Lorentzian distribution, however, the rms of the Lorentzian function is not defined. The super Gaussian distribution seems to be the best option~<ref name="sup-Gau"> F.J. Decker, SLAC-PUB-6684, Sep, 1994. </ref>, because rms values may be directly extracted.

Fig.~\ref{par-fit} shows the square of the rms ([math]\sigma^2_{s}[/math]) vs k_1L for x (horizontal) and y (vertical) beam projections along with the parabolic fits using Eq.~\ref{par_fit}. The emittances and Twiss parameters from these fits are summarized in Table~\ref{results}.



Fig. Square of rms values and parabolic fittings. .
Fig. Square of rms values and parabolic fittings. .
Parameter Unit Value
projected emittance [math]\epsilon_x[/math] [math]\mu[/math]m 0.37 [math]\pm[/math] 0.02
projected emittance [math]\epsilon_y[/math] [math]\mu[/math]m 0.30 [math]\pm[/math] 0.04
[math]\beta_x[/math]-function m 1.40 [math]\pm[/math] 0.06
[math]\beta_y[/math]-function m 1.17 [math]\pm[/math] 0.13
[math]\alpha_x[/math]-function rad 0.97 [math]\pm[/math] 0.06
[math]\alpha_y[/math]-function rad 0.24 [math]\pm[/math] 0.07
micro-pulse charge pC 11
micro-pulse length ps 35
energy of the beam E MeV 15 [math]\pm[/math] 1.6
relative energy spread [math]\Delta E/E[/math] % 10.4

Energy Spread Measurement

Energy scan was done to measure the energy profile of HRRL at nominal 12 MeV. A Faraday cup was placed at the end of the 45 degree beamline to measure the electron beam current bent by the first dipole. Dipole coil current were changed by 1 A increment and the Faraday cup currents were recorded. The scan results with corresponding beam energies are shown in the table below. The relation between dipole current and beam energy is given in the appendix.

The energy distribution of HRRL can be described by two skewed Gaussian fit overlapping.

2 Skewed Gaussian Fit

Hrrl 17May2012 12MeV En Spread2.png

The beam energy spread does not follow Gaussian distribution, but the overlapping of two skewed Gaussian found to be the best description of beam energy profile Media:Beam_Distributions_Beyond_RMS.pdf.



Sigma = 2.83516, Es = -0.57658

rms = 2.56472, skew = -0.94853


Sigma2 = 0.57440, Es2 = -0.21360

rms2 = 0.56719, skew2 = -0.34231


parameter Notation First Gaussian Second Gaussian
amplitude A 2.13894 10.88318
mean [math]\mu[/math] 12.07181 12.32332
sigma left [math]\sigma_L[/math] 4.46986 0.69709
sigma right [math]\sigma_R[/math] 1.20046 0.45170

Positron detection

DAQ setup

NaI Detectors

The NaI detectors have two outputs, one is at second last dynode and one anode signal. PMT base configuration of the NaI detectors is shown in the the figure. It takes ADC 5.7 [math]\mu[/math]s to convert analog signal to digital signal. The signal from anode was delayed 6 [math]\mu[/math]s by long cable and sent to the ADC.

HRRL Positron Our Modified PMT Base Design.png IAC NaI Detectors and Parts 7.png Hrrl pos det calb det3 r2637 r2636 2.png

Trigger for DAQ

The trigger for DAQ required a coincidence between one or more NaI detectors and the electron accelerator gun pulse. The last dynode signals from left and right NaI detectors were inverted using a Ortec ??? amplifier and sent to a Constant Fraction Discriminator (CFD Model specs).

RF noise from the accelerator is as large as the signal from the NaI detector. Since it is correlated in time with the gun pulse, the gun pulse was used to generate a VETO pulse that prevent the CFD from triggering on this RF noise.

After this discrimination and RF noise rejection, the discriminated dynode signals were sent to an Octalgate Generator (Model) that increased the width of the logic signals to prevent multiple pulses during a single electron pulse. Then the signals were sent to Quad Coincidence to generate AND logic between electron gun and dynode signals. The logic is set as: (Na Left && Gun Trigger) && (NaI Rgiht && Gun Trigger). This is to make sure we have trigger when photons back to back scatter to the NaI detectors when electron gun is on.

Then this trigger was sent to ORTEC Gate & Delay Generator. One of the out from gate generator was used to generate a gate to read analog signal from anode. Another output was delayed by 6 [math]\mu[/math]s, necessary time to convert the analog signal from anode to digital signal, and used as trigger for the DAQ.

Data Analysis

Back of the envelope calculation for e+/e- ratio


Signal extraction

For 3 MeV and on detector show all the steps

  1. Raw counts target in and out (calibrated energy)
  2. Normalized counts
  3. background subtracted
  4. Integral (zoomed in and with error)

Example of error propagation for the above

Raw counts target in and out

Lets take example of run#3735 for the data analysis.

The ingeral shown in read is from the background is subtracted spectrum.

run in: 3735 run out: 3737 Hrrl pos 27jul2012 data ana with Cuts r3735 ove r3736 No Norm DL.png Hrrl pos 27jul2012 data ana with Cuts r3735 ove r3736 No Norm DR.png

Some run parameters in 3735:

run number Reprate Run time Pulses Events e+ Counts NaI Detectors
3735 300 Hz 1002 s 301462 9045 256 +- 16

Electron Rate Calculation

A scintillator placed between quadrupole 9 and quarupole 10 (shown as in the following figures) was used to estimate electron current:

Hrrl pos jul2012 setup Scint RL 4.jpg


The electron beam current was changed to calibrate of the scintillator. The mean of the counts in scintillator decreased in the experiment as the current decreased, the change is linear.

run# Scope Pics FC1 area nVs Scint L area nVs Scint Left (Ch9) ADC9 mean events in scaler
3703 R3703 SCNT L.png [math]1201.1 \pm 10.1[/math] [math]4.4 \pm .3[/math] 1127.75 [math] \pm[/math] .7 [math]1126 \pm 0.8 [/math] first measurement at full current 7853 7855
3705 R3704 SCNT L.png [math]776.8 \pm 112[/math] [math]7.26 \pm 4.5[/math] 782.5 [math] \pm[/math] 1 [math]791.8 \pm 0.6[/math] cut the current in half 7591
3706 R3706 SCNT L.png [math]367.7 \pm 2.32[/math] [math]6.5 \pm .34[/math] 239.1 [math] \pm[/math] 0.6 [math] 242.1 \pm 0.3 [/math] cut the current to its 1/4 th 8154


The data was fitted with three methods to find calbiration, and the average and variance them are used to find the calibration.

The first method is fit the three data points with root. The second method, the point (0,0) introduced, and the line was forced to pass through this point. The point is introduced based on physics that when there is no electron beam, scintillator should have no counts. The slope was fitted by root. The fit is done in root.

In the second method, the curved is far off from the two data points when ADC channel number is large. The third fitting method is introduced to compensate it, in which fits are done manually. Two fits were done by this method, and average and variance of two fits were obtained.

The average and variance of these three methods were used for the calibration of the scintillator.

Fit Methods Fit Method 1 Fit Method 2 Fit Method 3 Average of Three Methods
Fit Curve Hrrl pos 27Jul2012 Charge Calb fit curve.png Hrrl pos 27Jul2012 Charge Calb fit curve fix point 1.png Hrrl pos 27Jul2012 Charge Calb fit curve my fix point 1.pngHrrl pos 27Jul2012 Charge Calb fit curve my fix point 2.png
Calibration [math] 1.063 \pm 0.013 [/math] nV s /ADC channel [math]0.789 \pm 0.004[/math] nV s /ADC channel [math] 0.94 \pm 0.02 [/math] nV s /ADC channel [math] 0.93 \pm 0.14 [/math] nV s /ADC channel

Electron Electron Rate Calculation for Run 3735

Total number of electrons in this run is [math]N_{e^-}= (2.99 \pm 0.45 ) \times 10^{16}.[/math]

Total charge of electrons in this run is [math]Q_{e^-} = (4.78 \pm 0.72 ) \times 10^{-3}~C.[/math]

Electron rate is [math] e^-_{rate} = (2.97 \pm 0.45) \times 10^{13}~Hz. [/math]

Average electron current is [math]I_{e^-} = (4.8 \pm 0.8 ) \times 10^{-6}~(A).[/math]

Electron rate error is [math]\Delta e^-_{rate} = \sqrt{(\frac{\partial e^-_{rate}}{\partial N_e^-})^2 \Delta N_{e^-}^2}[/math]

Here the error on electron counts comes from the combination of the error ADC channel to Faraday cup charge area calibration factor and the error on ADC 511 keV photon peak counts.

[math]\Delta N_{e^-}=\frac{\Delta Q_{e^-}}{e^-} =\frac{ \sqrt{ (\mbox{error on ADC peak count}) (cabliration) + (ADC~peak~count) (error~on~cabliration)} }{e^-} [/math]


Here, To find the average charge two methods were used. One method

Positron Rate Calculation

This a normalized spectrum (no background subtraction).

run in: 3735 Hrrl pos 27jul2012 data ana with Cuts r3735 Norm DL.png Hrrl pos 27jul2012 data ana with Cuts r3735 Norm DR.png

Positron rate calculated by: [math] e^+_{rate} = \frac{N_{e^+}}{t}[/math].

Error on positron rate calculated by: [math] e^+_{rate,~er} = \sqrt{\frac{(N_{e^+, er})^2}{t^2}}= \sqrt{\frac{N_{e^+}}{t^2}}[/math].


positron rate: [math] e^+_{rate} = 0.259 \pm 0.016 ~ Hz[/math].

Positron to Electron Ratio

positron to electron ratio: [math]R = \frac{N_{e^+}}{N_{e^-}} = (8.7 \pm 1.4)\times10^{-15}.[/math]

positron to electron current ratio: [math] \frac{N_{e^+}}{I_{e^-}} = \frac{0.26 ~ Hz ~ e^+}{4.8 ~ \mu ~ A ~ e^-}[/math]

Errors

[math]R = \frac{N_{e^+}}{N_{e^-}} = \frac{ 0.259 \pm 0.016 Hz}{ (2.98 \pm 0.45) \times 10^{13} Hz} = 0.087 \times 10^{-13} = 8.7 \times 10^{-15}[/math]


[math]\Delta R = \sqrt{\frac { \Delta N_{e^+}^2 }{ N_{e^-}^{2} } + (- \frac{ N_{e^+} }{ N_{e^-}^{2} })^2 \Delta N_{e^-}^{2} } = \frac{\sqrt{ \Delta N_{e^+}^{2} + \frac{ N_{e^+}^{2} }{ N_{e^-}^{2} } \Delta N_{e^-}^{2} }}{ N_{e^-}} = \frac{\sqrt{ \Delta N_{e^+}^{2} + R^2 \Delta N_{e^-}^{2} }}{ N_{e^-}}[/math]



[math]\Delta R = \frac{\sqrt{ 0.016^{2} + ( 8.7 \times 10^{-15} \times 4.49 \times 10^{12})^{2} }}{ 2.98\times 10^{13}} [/math]

[math] = \frac{\sqrt{ 0.016^{2} + ( 8.7 \times 4.49 \times 10^{-3})^{2} }}{ 2.98\times 10^{13}} [/math]
[math] = \frac{\sqrt{ 0.000256 + 0.001526}}{ 2.98\times 10^{13}} [/math]
[math] = \frac{\sqrt{ 0.001782}}{ 2.98\times 10^{13}} [/math]
[math] = 0.014 \times 10^{-13} [/math]
[math] = 1.4 \times 10^{-15} [/math]

Background subraction

The background is taken when the annihilation target, T2, is out. The difference in T1 run and T2 out run is the measure of positrons annihilated at T2.

Run Number T2 Position [math]R = \frac{N_{e^+}}{N_{e^-}} [/math]
3735 in [math](8.7 \pm 1.4)\times 10^{-15}[/math]
3736 out [math](1.5 \pm 0.8)\times 10^{-16}[/math]
3737 in [math](8.1 \pm 1.3)\times 10^{-15}[/math]

[math]\bar{R}_{in}= (8.40 \pm 0.96)\times 10^{-15} [/math]

[math]\bar{R}_{out}= (1.5 \pm 0.8)\times 10^{-16} [/math]

[math]{R}_{3MeV} = \bar{R}_{in}- \bar{R}_{out}=( 8.25 \pm 0.96 )\times 10^{-15}[/math]

Ratio of Positron Rate to Electron Rata

The measured ratio of positron to electron ratio is given the following table and figure.

Energy (MeV) Positron to Electron Ratio
1 [math] ( 1.9 \pm 0.9 )\times 10^{-16} [/math]
2 [math] ( 6.9 \pm 2.4 )\times 10^{-16} [/math]
3 [math] ( 8.3 \pm 1.0 )\times 10^{-15}[/math]
4 [math] ( 4.2 \pm 0.8 )\times 10^{-15}[/math]
5 [math] ( 6.2 \pm 1.6 )\times 10^{-16}[/math]

HRRL Jul2012 pos to ele ratio 1.png

Sources of Systematic Errors

Determine sources of systematic errors


Error on Energy (x-axis)

To find Error on the energy, the electron beam is directed to the phosphorous screen at the end of the 90 degree beamline. The beam centered then steering away from the center. The current change on the dipole [math]\Delta I[/math] when beam is center and at the edge is 0.2 A. This is corresponding to 0.13 MeV in beam energy.

Error on Ratio (y-axis)

Error on electron beam is derived from:


Error on positron beam rate is derived from: [math]\sqrt{\frac{positron~rate}{run~time}}[/math]

Annihilation target angle

Use simulation to determine how sensitive annihilation of positrons is to angle.

What is the dependence of the annihilation target angle with the probability of a positron annihilating in the target and producing a photon that is detected by the NaI detector,


What is the distribution of 511s as a function of angle phi when theta is 90 degrees?  Are they uniformly produced?

Energy cut systematics

How does the positron production efficiency change when you change the range of the 511 cut.

Efficiency measurement

acceptance, quad collection efficiency,

Simulation

July2012PosSimulation

A simulation was performed using the package G4beamline(ref Muons inc) to study the processes of position generation and transportation. "G4beamline is a particle tracking and simulation program based on the Geant4 (refernce G4) toolkit that is specifically designed to easily simulate beamlines and other systems using single-particle tracking." Since the ratio of e+/e- during the positron generation process is very low (on the order of 0.001) and the positron beam loss during the transportation is large, it was necessary to divide whole process into 5 steps. A new beam event generator is created based on the results of the previous step in the simulation.

The first step generates electrons according to a measurement made of the accelerator that was used in the experiment. Electrons are transported to T1 in vacuum and as a result the interactions of the electron with T1 produce positrons. The second step is the transportation of the positrons generated at T1 to the entrance of first dipole magnet. The third step is the transportation of the positrons from the entrance of the first dipole magnet to the end of the second dipole. The fourth step is the transportation of the beam from the exit of the second dipole to the T2 target. The fifth step is the positron beam interaction with T2 and detection of the resulting 511 keV photons.

Step 1 - The Electron Beam Generation and Transpiration to T1

In this step, an electron beam is generated from the experimental measure electron beam parameters. The Twis parameters described in the earlier chapter used electron generated the beam. The energy distribution is of the beam is measured and shown in the Fig.~\ref{fig:sim-ele-En}. The blue dots are measurements and red line are the fit composed of two skewed Gaussian distributions. The fit parameters are given in the Table~\ref{tab:sim-skew-Gau}


Hrrl 17May2012 12MeV En Spread2.png


Amplitude Mean (MeV) [math]\sigma _L[/math] [math]\sigma _R[/math]
First Gaussian 2.14 12.07 4.47 1.20
Second Gaussian 10.88 12.32 0.70 0.45

Series of virtual detectors are placed along the beamline to sample the beam. As an example, in the Fig.~\ref{fig:sim-T1-3det} shown are three detectors and the T1. The electron beam is observed at DUPT1 (Detector 25.52 mm UPstram of T1) and positrons (or electrons and photons) generated during the interaction of electron beam with T1 are observed at DT1 (Detector of T1) and DDNT1 (Detector DowN 25.52 mm stream of T1). In the Fig.~\ref{fig:sim-ele-pos}, the incoming electron beam (observed at DUPT1) energy distribution (red) and positrons generated by this electron beam (observed at DDNT1) is shown in blue.

T1: Positron production target; DUPT1: upstream detector; DDNT1: down stream (DDNT1); DT1: detector right after T1.


Results

DDNT1

13,799,743,900 electrons were shot on T1 and resulted positron beam observed at DDNT1 is as shown below Figures.

STSimS1 En DDNT1 e+.png

STSimS1 X DDNT1.png

STSimS1 Y DDNT1.png

STSimS1 XP DDNT1.png

STSimS1 YP DDNT1.png

STSimS1 XY DDNT1.png

STSimS1 XY DDNT1 zoom.png

The Y-position distribution of the beam shown in Figure ~\ref{sim-DDNT1-y-vs-x} has a sharp drop in the region between -25.8 mm and -27.2 mm that corresponds to the boundary of the target T1. Figure ~\ref{sim-DDNT1-T1-geo} shows the geometry of the target T1 and the sensitive detector DDNT1. If the target size was increased, it would eventually intersected the detector DDNT1 at a distance of 25.8 mm from the beam center. A 1.4 mm wide stripe of low counts is visible on DDNT1 that is a result of the target's thickness of 1.016 mm and the 45 degree angle of intersection. ([math]1.016 \sqrt{2}=1.44[/math]). The edge of the target does not produce many positrons compared to the face of the target, and as a result you see the stripe.

As shown in figures ~\ref{sim-DDNT1-theta-vs-y} and ~\ref{sim-DDNT1-theta-vs-y-zoom} (zoomed figure) the positron distribution decrease occures at [math]\theta = 45^o[/math]. Positrons are emitted from both the downstream and upstream side of the target. As shown in the figure, positrons from the downstream side of the target intersect the detector at angles below 45 degrees while positrons from the upstream side of the target begin to hit the detector at angles beyond 45 degrees. The 1.4 mm gap represents the transition of positrons between these two extremes.


Hrrl pos sim pos sharp drop geometry2.png


STSimS1 YYP DDNT1.png

STSimS1 YYP DDNT1 zoom.png

DQ4 and DD1

Resulted positron beam on DQ1 and DD1 are shown in below Figures.

STSimS1 En DQ4 e+.png

STSimS1 En DD1 e+.png

Step 2 - Transportation of the The Positron Beam after T1 to The Entrance of The First Dipole

In this step, the positrons generated in the first step divided into 1~keV/c momentum bins and each bin is sampled individually since the momentum of the positrons related to their divergence. Multiple beams with individual weights generated at downstream T1 detector DDNT1 and transported to entrance of the D1. Virtual detectors are placed at the entrance of Q4 and entrance of D1 to track positrons and generate beam for next step as shown in the Fig~\ref{fig:Sim-s1-setup}.

STSimSetupS2.png

Conclusion

Appendix

1. Dipole Coil Current vs. Beam energy

Dipole    FC        En
Coil      Current   
Current   Reading
(A)       (mA)      (MeV)
8         0.5       4.3119
9         0.6       4.8896
10        0.67      5.4570
11        0.716     6.0141
12        0.752     6.5610
13        0.828     7.0975
14        0.896     7.6238
15        1.112     8.1399
16        1.328     8.6456
17        1.624     9.1411
18        1.896     9.6262
19        2.448     10.1012
20        3.36      10.5658
21        4.82      11.0201
22        6.58      11.4642
22.2      7.88      11.5518
22.5      9.24      11.6824
22.7      10.0      11.7690
23        10.2      11.8980
23.1      11.2      11.9408
23.2      11.56     11.9836
23.3      13.04     12.0262
23.5      13.2      12.1111
23.8      13.04     12.2377
24        13.48     12.3216
24.2      12.36     12.4050
24.5      11.24     12.5295
24.7      10.2      12.6119
25        10.28     12.7348
25.1      8.6       12.7756
25.2      6.92      12.8162
25.5      6.2       12.9376
25.7      4.84      13.0180
26        3.64      13.1378
26.5      1.82      13.3354
27        1.28      13.5305
28        0.56      13.9129
29        0.364     14.2850
30        0.364     14.6469

2. Radiation Footprint

References

<references/>