Difference between revisions of "2n BKG data"
Jump to navigation
Jump to search
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | BKG effect investigated with the paddle detector: | ||
+ | |||
<math>I_{e^-} = 30 mA</math>, <math>Pw=20 ns</math>, <math>R=300Hz</math>, <math>E_{e^-}=10.5 MeV</math> | <math>I_{e^-} = 30 mA</math>, <math>Pw=20 ns</math>, <math>R=300Hz</math>, <math>E_{e^-}=10.5 MeV</math> | ||
Line 9: | Line 11: | ||
Detector G: HV(G1) = -1700 V, HV(G2) = -1650 V. | Detector G: HV(G1) = -1700 V, HV(G2) = -1650 V. | ||
− | There was 2" of lead in front of the Det G. Det G was on the floor. | + | There was 2" of lead in front of the Det G. Det G was placed on the floor. |
Case A: Target out, radiator in - Counting rate (G1) = 1/168 (gammas/pulse) | Case A: Target out, radiator in - Counting rate (G1) = 1/168 (gammas/pulse) | ||
Case B: Target out, radiator in, downstream collimator blocked - Counting rate (G1) = 1/485 (gammas/pulse) | Case B: Target out, radiator in, downstream collimator blocked - Counting rate (G1) = 1/485 (gammas/pulse) | ||
+ | |||
+ | |||
+ | ---- | ||
+ | |||
+ | The BKG measured with "Ilyusha" | ||
+ | |||
+ | [[File:HRRL_BKG_study.jpeg | 600 px]] |
Latest revision as of 23:12, 7 December 2012
BKG effect investigated with the paddle detector:
, , ,
Upstream collimator diamater = 0.25"
Downstream collimator diamater = 2.0"
2 Al sheets as bremsstrahlung radiator;
Detector G: HV(G1) = -1700 V, HV(G2) = -1650 V.
There was 2" of lead in front of the Det G. Det G was placed on the floor.
Case A: Target out, radiator in - Counting rate (G1) = 1/168 (gammas/pulse)
Case B: Target out, radiator in, downstream collimator blocked - Counting rate (G1) = 1/485 (gammas/pulse)
The BKG measured with "Ilyusha"