Difference between revisions of "2n BKG data"

From New IAC Wiki
Jump to navigation Jump to search
(Created page with "<math>I_{e^-} = 30 mA</math>")
 
 
(10 intermediate revisions by the same user not shown)
Line 1: Line 1:
<math>I_{e^-} = 30 mA</math>
+
BKG effect investigated with the paddle detector:
 +
 
 +
<math>I_{e^-} = 30 mA</math>, <math>Pw=20 ns</math>, <math>R=300Hz</math>, <math>E_{e^-}=10.5 MeV</math>
 +
 
 +
Upstream collimator diamater = 0.25"
 +
 
 +
Downstream collimator diamater = 2.0"
 +
 
 +
2 Al sheets as bremsstrahlung radiator;
 +
 
 +
Detector G: HV(G1) = -1700 V, HV(G2) = -1650 V.
 +
 
 +
There was 2" of lead in front of the Det G. Det G was placed on the floor.
 +
 
 +
Case A: Target out, radiator in - Counting rate (G1) = 1/168 (gammas/pulse)
 +
 
 +
Case B: Target out, radiator in, downstream collimator blocked - Counting rate (G1) = 1/485 (gammas/pulse)
 +
 
 +
 
 +
----
 +
 
 +
The BKG measured with "Ilyusha"
 +
 
 +
[[File:HRRL_BKG_study.jpeg | 600 px]]

Latest revision as of 23:12, 7 December 2012

BKG effect investigated with the paddle detector:

[math]I_{e^-} = 30 mA[/math], [math]Pw=20 ns[/math], [math]R=300Hz[/math], [math]E_{e^-}=10.5 MeV[/math]

Upstream collimator diamater = 0.25"

Downstream collimator diamater = 2.0"

2 Al sheets as bremsstrahlung radiator;

Detector G: HV(G1) = -1700 V, HV(G2) = -1650 V.

There was 2" of lead in front of the Det G. Det G was placed on the floor.

Case A: Target out, radiator in - Counting rate (G1) = 1/168 (gammas/pulse)

Case B: Target out, radiator in, downstream collimator blocked - Counting rate (G1) = 1/485 (gammas/pulse)



The BKG measured with "Ilyusha"

HRRL BKG study.jpeg