PbF2 CrystalNumber18: Difference between revisions
Jump to navigation
Jump to search
| (One intermediate revision by the same user not shown) | |||
| Line 75: | Line 75: | ||
|beam start: || 12:54 | |beam start: || 12:54 | ||
|- | |- | ||
|beam stop: || | |beam stop: || 14:55 | ||
|} | |} | ||
;Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away) | |||
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt <math>\times</math> ns | |||
@ 13:05 [[Image:Block18 1.05pm.JPG | 200 px]] | |||
@ 13:15 [[Image:Block18 1.15pm.JPG | 200 px]] | |||
@ 13:25 [[Image:Block18 1.25pm.JPG | 200 px]] | |||
@ 13:35 [[Image:Block18 1.35pm.JPG | 200 px]] | |||
@ 13:45 [[Image:Block18 1.45pm.JPG | 200 px]] | |||
@ 13:55 [[Image:Block18 1.55pm.JPG | 200 px]] | |||
@ 14:05 [[Image:Block18 2.05pm.JPG | 200 px]] | |||
@ 14:15 [[Image:Block18 2.15pm.JPG | 200 px]] | |||
@ 14:25 [[Image:Block18 2.25pm.JPG | 200 px]] | |||
@ 14:35 [[Image:Block18 2.35pm.JPG | 200 px]] | |||
@ 14:45 [[Image:Block18 2.45pm.JPG | 200 px]] | |||
@ 14:55 [[Image:Block18 2.55pm.JPG | 200 px]] | |||
;Dose rate measurements (@1457 hours) | |||
{| border="1" | |||
| <math>\gamma</math>-radiation || 5 mR/hr | |||
|- | |||
| <math>\beta</math>-radiation: || 10 mR/hr | |||
|} | |||
[http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back] | [http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back] | ||
Latest revision as of 22:39, 5 December 2007
Below are the resulting transparency measurements for PbF2 block # 18
12/4/07
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns) |
| beam start: | 10:42 |
| beam stop: | 12:42 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns
- Dose rate measurements (@1255 hours)
| [math]\displaystyle{ \gamma }[/math]-radiation | 500 uR/hr |
| [math]\displaystyle{ \beta }[/math]-radiation: | 500 uR/hr |
- Transparency Measurements (@1525 hours)
12/5/07
- Transparency measurement (1235)
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns) |
| beam start: | 12:54 |
| beam stop: | 14:55 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns
- Dose rate measurements (@1457 hours)
| [math]\displaystyle{ \gamma }[/math]-radiation | 5 mR/hr |
| [math]\displaystyle{ \beta }[/math]-radiation: | 10 mR/hr |