Difference between revisions of "PAA Selenium ActivityCalc"

From New IAC Wiki
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
(No difference)

Latest revision as of 18:44, 20 May 2019

PAA_Selenium#PAA_Selenium_ActivityCalc

Previous Irradiation

A 0.91 g of Selenium was irradiated on Feb 13, 2017 and measured using Detector B

The sample was irradiated with 250Hz beam with [math] 90 \times 10^{-3} [/math] Amp current. The pulse width was [math] 4 \times 10^{-6} [/math] seconds at an energy of 20Mev = 1.44kW. The sample began irradiation at 8:00AM and was irradiated for 8 hours in the rotating sample holder, ending at 16:00 on 2/13/17.

SeRun_02-13-17

LB_IAC_Radiator_Specs

LB_Feb2017_Se_Investigations#Pure_Selenium_Sample

Feb_2017_Runlist