Difference between revisions of "201309 R1ProgressRep"

From New IAC Wiki
Jump to navigation Jump to search
Line 1: Line 1:
 
 
=09/04/13=
 
=09/04/13=
  
Line 28: Line 27:
 
|}
 
|}
  
 +
=9/20/13=
 +
 +
Q&A tasks remaining
 +
 +
#discovered current draw beyond 20 uA when Sector 1 HV_SL1 board 7 voltage is raising to 500 volts.  need to debug
 +
#replaced Sector 1 HV_SL1 board 4 due to a broken bus pin
 +
#
  
 
[[CLAS12_R1_Progress_Reports#September_2013]]
 
[[CLAS12_R1_Progress_Reports#September_2013]]

Revision as of 16:35, 20 September 2013

09/04/13

Replaced 10 clean room filters


Tasks remaining:

  1. Measure all Field and Sense wire tensions prior to potting
  2. pot S2 & S3
  3. install Windows on S2 & S3
  4. install HVBs & STBs onto S2 & S3
  5. burn in S2 & S3
  6. finish Q&A on all chambers


David Coneff is managing two student workers and plans to finish the above remaining tasks before Jan 2014 as a part time worker, their work schedule is given below.


Mon Tues Wed Thurs Fri Sat Sun
1-5pm 1-5pm 1-5pm 11am-5pm

9/20/13

Q&A tasks remaining

  1. discovered current draw beyond 20 uA when Sector 1 HV_SL1 board 7 voltage is raising to 500 volts. need to debug
  2. replaced Sector 1 HV_SL1 board 4 due to a broken bus pin

CLAS12_R1_Progress_Reports#September_2013