Difference between revisions of "Ionization Chamber"
Jump to navigation
Jump to search
Line 12: | Line 12: | ||
[[Qweak_Chamber_Assembly]]<br> | [[Qweak_Chamber_Assembly]]<br> | ||
+ | |||
+ | |||
+ | The scope pictures(100ns/div and 5 mv/div) below shows the Qweak GEM chamber's "TrigOut" pulse caused by a cosmic ionization event in the Qweak R1 detector. The "TrigOut" pulse represents electrons leaving the last GEM preamplifier stage and is therefore a positive going pulse. The high voltage was set to -3400 Volts on the cathode <math>(V_{Drift})</math> and -3100 Volts on the GEM foil voltage divider network <math>(V_{GEMFoil})</math> which powers all three GEM foil preamplifier stages. The chamber was filled with a gas mixture composed of 90% Argon and 10% Co2 by volume. | ||
+ | |||
+ | [[Image:QweakTrigOut_Scope_and_Detector_3-04-09_1.jpg|300px]] | ||
[http://wiki.iac.isu.edu/index.php/Qweak Go Back] [[Qweak]] | [http://wiki.iac.isu.edu/index.php/Qweak Go Back] [[Qweak]] |
Revision as of 01:20, 8 April 2009
Qweak Chamber machining
Qweak_Chamber_Assembly
The scope pictures(100ns/div and 5 mv/div) below shows the Qweak GEM chamber's "TrigOut" pulse caused by a cosmic ionization event in the Qweak R1 detector. The "TrigOut" pulse represents electrons leaving the last GEM preamplifier stage and is therefore a positive going pulse. The high voltage was set to -3400 Volts on the cathode
and -3100 Volts on the GEM foil voltage divider network which powers all three GEM foil preamplifier stages. The chamber was filled with a gas mixture composed of 90% Argon and 10% Co2 by volume.