Difference between revisions of "PositronTargetWorkByChrissJackson"
|  (→ports) | |||
| (28 intermediate revisions by 2 users not shown) | |||
| Line 3: | Line 3: | ||
| ;Goal | ;Goal | ||
| : Construct a Tungsten target and vacuum enclosure to be used for generating positrons using an incident electron beam. | : Construct a Tungsten target and vacuum enclosure to be used for generating positrons using an incident electron beam. | ||
| + | |||
| + | =Geometry= | ||
| + | |||
| + | ==Tungsten Disks== | ||
| + | |||
| + | ;Dimensions are in cm | ||
| + | |||
| + | [[File:HRRL_PosTargetDesign_4-20-11.png| 200 px]] | ||
| + | |||
| + | http://www.alibaba.com/product-gs/346924116/Tungsten_Disk_With_Screw.html | ||
| + | |||
| + | |||
| + | http://www.zlxtech.com.cn/products.asp?productcode=7401000404 | ||
| + | |||
| + | http://www.cleveland-tungsten.com/ | ||
| + | |||
| + | |||
| + | If the motor has a radius of 2.5" and I want to shield the motor from the beam using 2" of Pb and the beam is about 1" in diameter then I want a Tungsten disk that is  | ||
| + | |||
| + | 5.21" in radius = 13.25 cm in radius ~ 30 cm in diameter | ||
| + | |||
| + | |||
| + | ==Target Chamber design== | ||
| + | |||
| + | Latest Design From empire and Sadiq's measurement of the available space | ||
| + | |||
| + | |||
| + | |||
| + | {| border="1" cellpadding="20" cellspacing="0" | ||
| + | |- | ||
| + | |[[File:EmpMagHRRLPositronTargetChamberDrw_9-20-11.png | 100 px]]||[[File:HRRLPositronTargetSpace_10-5-11.png | 100 px]] || [[File:HRRLPositronTargetCoupler_10-5-11.png | 100 px]]|| [[File:HRRLPositronTargetHub_10-5-11.png | 100 px]] | ||
| + | |- | ||
| + | | Target motor Design  || Available beam line space || Motor axle coupling to rotary union || Hub and spline to attache targets | ||
| + | |} | ||
| + | |||
| + | |||
| + | |||
| + | Dimensions for the target chamber box. Measurements in inches. updated 11 May 2012. Holes for tubing still missing, need to measure. | ||
| + | |||
| + | {| border="1" cellpadding="20" cellspacing="0" | ||
| + | |- | ||
| + | |[[File:Target_box-bottom.jpg | 100 px]]||[[File:Target_box-front.jpg | 100 px]] || [[File:Target_box-left.jpg | 100 px]]|| [[File:Target_box-iso.jpg | 100 px]] | ||
| + | |- | ||
| + | | Bottom view || Front View || Left View || Isometric View | ||
| + | |} | ||
| + | |||
| + | |||
| + | ==ports== | ||
| + | |||
| + | |||
| + | |||
| + |  {| border="1"  |cellpadding="20" cellspacing="0  | ||
| + | |- | ||
| + | | Parts     || Quantity || Items connecting to Target Chamber  | ||
| + | |- | ||
| + | |  10 - pin wiring feedthrough || 1 || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=9132004 Feedthrough]   | ||
| + | |- | ||
| + | |  cooling lines  ||  2 || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=611005 Cooling Hoses]  | ||
| + | |- | ||
| + | | IR optical window  || 2  || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=9712007  Optical Window]  | ||
| + | |- | ||
| + | | Beam line || 2  || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=100021  Flange]  | ||
| + | |- | ||
| + | | Ion Pump || 1  || [http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=100021  Flange]  | ||
| + | |- | ||
| + | | Roughing Pump || 1  ||  | ||
| + | |} | ||
| + | |||
| + | |||
| + | |||
| + | 1.) Lid with a lip that bolts on. | ||
| + | |||
| + | 2.) bolt pattern on the bottom for the motor mounts | ||
| + | |||
| + | 3.) find cooling lines for inside the box | ||
| + | |||
| + | 4.) Find elbows for the rotary unions. | ||
| + | |||
| + | . | ||
| + | . | ||
| + | . | ||
| + | . | ||
| + | 100.) Design a target mounting system | ||
| + | |||
| + | =Equipment= | ||
| + | |||
| + | ==Motor== | ||
| + | |||
| + | == Controller== | ||
| + | |||
| + | ==Vacuum Chamber== | ||
| + | |||
| + | ==Feedthroughs== | ||
| + | |||
| + | [[File:liquid_nitro_tubing.gif]] | ||
| + | |||
| + | A: 5.88 | ||
| + | B: 3.00 | ||
| + | C: 4.25 | ||
| + | D: 4.63 | ||
| + | |||
| + | http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=611005 | ||
| + | |||
| + | =Performance tests= | ||
| + | |||
| + | ==Heat load calculation== | ||
| [[HRRL_Positron_Rotating_W_Target]] | [[HRRL_Positron_Rotating_W_Target]] | ||
Latest revision as of 17:59, 15 May 2012
- Chriss Jackson's Positron Target development logbook
- Goal
- Construct a Tungsten target and vacuum enclosure to be used for generating positrons using an incident electron beam.
Geometry
Tungsten Disks
- Dimensions are in cm
http://www.alibaba.com/product-gs/346924116/Tungsten_Disk_With_Screw.html
http://www.zlxtech.com.cn/products.asp?productcode=7401000404
http://www.cleveland-tungsten.com/
If the motor has a radius of 2.5" and I want to shield the motor from the beam using 2" of Pb and the beam is about 1" in diameter then I want a Tungsten disk that is 
5.21" in radius = 13.25 cm in radius ~ 30 cm in diameter
Target Chamber design
Latest Design From empire and Sadiq's measurement of the available space
|  |  |  |   | 
| Target motor Design | Available beam line space | Motor axle coupling to rotary union | Hub and spline to attache targets | 
Dimensions for the target chamber box. Measurements in inches. updated 11 May 2012. Holes for tubing still missing, need to measure.
|  |  |  |   | 
| Bottom view | Front View | Left View | Isometric View | 
ports
| Parts | Quantity | Items connecting to Target Chamber | 
| 10 - pin wiring feedthrough | 1 | Feedthrough | 
| cooling lines | 2 | Cooling Hoses | 
| IR optical window | 2 | Optical Window | 
| Beam line | 2 | Flange | 
| Ion Pump | 1 | Flange | 
| Roughing Pump | 1 | 
1.) Lid with a lip that bolts on.
2.) bolt pattern on the bottom for the motor mounts
3.) find cooling lines for inside the box
4.) Find elbows for the rotary unions.
. . . . 100.) Design a target mounting system
Equipment
Motor
Controller
Vacuum Chamber
Feedthroughs
A: 5.88 B: 3.00 C: 4.25 D: 4.63
http://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&p=611005