Difference between revisions of "05/12/2011 random coincidence cosmic test"
Jump to navigation
Jump to search
Line 71: | Line 71: | ||
− | So what | + | So what we are measured? |
:purely random events from different reaction?. But why they are depend from distance? | :purely random events from different reaction?. But why they are depend from distance? | ||
:maybe some of them is the sub-products from one events separated in space? (air showers) | :maybe some of them is the sub-products from one events separated in space? (air showers) |
Revision as of 22:00, 12 May 2011
The powers are:
PS1 and PS2: -1000 V (the old 2-channel TENNELEC TC952) n's: -1100 V (the new 2-channel C.A.E.N N471)
The thresholds are:
PS1 and PS2: -80 mV n's: -200 mV
The discriminator widths are:
PS1: -20 ns PS2: -10 ns n's: -20 ns
Let's do the random coincidence cosmic ray test 1.
PS1 and PS2 is about 30 cm away from each other. And let's look on the coincidence signal between PS1 and PS2:
total counts | time | counts/min | counts/sec | |
---|---|---|---|---|
PS1 | 70 min | |||
PS1 | 70 min | |||
PS1+PS2 (30 cm away) | 70 min |
And below my scope pictures of this rear event:
Let's do the random coincidence cosmic ray test 2.
But now the distance between PS1 and PS2 is about 5 cm. And let's look on the coincidence signal between PS1 and PS2:
total counts | time | counts/min | counts/sec | |
---|---|---|---|---|
PS1 | 70 min | |||
PS1 | 70 min | |||
PS1+PS2 (5 cm away) | 70 min |
And below my scope pictures of no so rear event as before:
So what we are measured?
- purely random events from different reaction?. But why they are depend from distance?
- maybe some of them is the sub-products from one events separated in space? (air showers)