Difference between revisions of "Beamline Parts"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
| Line 21: | Line 21: | ||
|   The 24 VDC is for the solenoid. |   The 24 VDC is for the solenoid. | ||
| − | |||
|   The large round connector in your photos is for the electrical position indicators. The contact rating is up to 50 VDC at 3 A or 250 VAC at 5 A max. |   The large round connector in your photos is for the electrical position indicators. The contact rating is up to 50 VDC at 3 A or 250 VAC at 5 A max. | ||
Revision as of 23:13, 4 May 2011
Mini UHV gate valve
Valve with pneumatic actuator:
single acting with closing spring (NC)
ISO-KF and CF-F
Manual: File:Mini UHV gate valve Manual.pdf
Leak rate: body / valve seat:
Pressure range: mbar to 2 bar (abs)
1 millibar = 0.750061683 torr = 0.75 torr
The 24 VDC is for the solenoid. The large round connector in your photos is for the electrical position indicators. The contact rating is up to 50 VDC at 3 A or 250 VAC at 5 A max.
Sadiq, You require 55 – 100 psig into the solenoid. Applying 24 VDC to the solenoid will open the valve and removing it will close the valve. Your valve is a normally closed valve, meaning it is spring closed. Reference the part number in the manual that ends in 41. Give me a call If you have any questions. Regards, Bill McPheeters VAT Sales Engineer - Austin, TX T: 512-280-8050, F: 512-280-8054