Difference between revisions of "Neutron Polarimeter"
Jump to navigation
Jump to search
Line 79: | Line 79: | ||
<math>\delta T_n \left(\delta t\right) = -\ \frac{m\ l^2 \delta t}{\left(1-\left(\frac{l}{c\ t}\right)^2\right)^{3/2}c^2 t^3}</math> | <math>\delta T_n \left(\delta t\right) = -\ \frac{m\ l^2 \delta t}{\left(1-\left(\frac{l}{c\ t}\right)^2\right)^{3/2}c^2 t^3}</math> | ||
− | |||
Also we need the neutron's time of flight as function of neutron's kinetic energy: | Also we need the neutron's time of flight as function of neutron's kinetic energy: | ||
Line 91: | Line 90: | ||
Using formulas above: | Using formulas above: | ||
− | + | Neutron time of flight: | |
− | <math> | + | <math>t(T_n = 10\ MeV) = 23\ ns</math> |
− | |||
− | |||
− | |||
+ | Neutron kinetic energy errors are: | ||
− | + | <math>\delta T_n(\delta t = 1\ ns) = 0.88\ MeV</math> | |
+ | <math>\frac{\delta T_n}{T_n} = \frac{0.88\ MeV}{10\ MeV} = 8.8\ %</math> | ||
+ | |||
+ | |||
+ | And photon energy errors are: | ||
+ | |||
+ | <math>\delta T_{\gamma} = 2.051\cdot \delta T_n = 2.051\cdot 0.88\ MeV = 1.81\ MeV </math> | ||
+ | <math>\frac{\delta T_{\gamma}}{T_{\gamma}} = \frac{1.80\ MeV}{(2.051\cdot 10 + 1.715)\ MeV} = 8.1\ %</math> | ||
+ | |||
+ | |||
+ | |||
+ | Below are some examples for different detector distance and neutron kinetic energy: | ||
{| height="10" border="1" cellpadding="6" cellspacing="0" | {| height="10" border="1" cellpadding="6" cellspacing="0" |
Revision as of 15:43, 5 April 2011
Analysis of energy dependence
four-vectors algebra
writing four-vectors:
Doing four-vector algebra:
Detector is located at
, so
and visa versa
how it looks
low energy approximation
As we can see from Fig.2 for low energy neutrons (0-21 MeV)
energy dependence of incident photons is linear
Find that dependence. We have:
So, the equation of the line is:
Finally for low energy neutrons (0-21 MeV):
example of error calculation
example 1
Say, we have, 10 MeV neutron with uncertainty 1 MeV, the corresponding uncertainly for photons energy is:
example 2
Say, the neutron's time of flight uncertainly is 1 ns
The neutron's kinetic energy is:
And:
Also we need the neutron's time of flight as function of neutron's kinetic energy:
Say, we have 10 MeV neutron, 1 m away detector, and neutron's time of flight uncertainty is 1 ns
Using formulas above:
Neutron time of flight:
Neutron kinetic energy errors are:
And photon energy errors are:
Below are some examples for different detector distance and neutron kinetic energy:
1 ns | 1 m | 5 MeV | 0.103 | 32 ns | 0.31 MeV | 6.2 % | 0.64 MeV | 5.3 % |
1 ns | 1 m | 10 MeV | 0.145 | 23 ns | 0.88 MeV | 8.8 % | 1.81 MeV | 8.1 % |
1 ns | 1 m | 20 MeV | 0.203 | 16 ns | 2.51 MeV | 12.6 % | 5.16 MeV | 12.1 % |
1 ns | 1 m | 0.5 MeV | 0.033 | 102 ns | 0.010 MeV | 1.9 % | ||
1 ns | 1 m | 1 MeV | 0.046 | 72 ns | 0.028 MeV | 2.8 % | ||
1 ns | 1 m | 2 MeV | 0.065 | 51 ns | 0.078 MeV | 3.9 % | ||
1 ns | 1 m | 4 MeV | 0.092 | 36 ns | 0.22 MeV | 5.5 % |