Difference between revisions of "HRRL 7-30-09"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
| (59 intermediate revisions by the same user not shown) | |||
| Line 7: | Line 7: | ||
| Energy  | | Energy  | ||
|-  | |-  | ||
| − | | 8 mA ||   | + | | 8 mA || 100 ns || 1 Hz|| 3 MeV    | 
|}  | |}  | ||
<br>  | <br>  | ||
| + | |||
=cable names=  | =cable names=  | ||
| Line 17: | Line 18: | ||
| Description  | | Description  | ||
|-  | |-  | ||
| − | | 2223A1 ||  | + | | 2223A1 || Front Scintillator  | 
|-  | |-  | ||
| − | | 2223A2 ||  | + | | 2223A2 || Rear Scintilaltor  | 
|-  | |-  | ||
| − | | 2223A3 ||  | + | | 2223A3 || ADC Gate From counting house to Experimental Cell  | 
|-  | |-  | ||
| − | | 2223A4 ||  | + | | 2223A4 || TDC start pulse from counting house to experimental cell  | 
|-  | |-  | ||
| − | | 2223A5 ||  | + | | 2223A5 || Coincidenc between front + rear Scint + Gun pulser to scaler channel 8  | 
|-  | |-  | ||
| − | | 2223A6 ||  | + | | 2223A6 || Metalica sense wire 4  | 
|-  | |-  | ||
| − | | 2223A7 ||  | + | | 2223A7 ||  G0 MCLK for   | 
|-  | |-  | ||
| − | | 2223A8 ||  | + | | 2223A8 || Plastica sense wire 4  | 
|-  | |-  | ||
| − | | 2223A9 ||  | + | | 2223A9 || scaler channel 4  | 
| + | |-  | ||
| + | | 2223A10 || Front scintillator to ADC  | ||
| + | |-  | ||
| + | | 2223A11 ||scaler channel 1  | ||
| + | |-  | ||
| + | | 2223A12 || DAQ trigger  | ||
|}  | |}  | ||
<br>  | <br>  | ||
| + | |||
| + | HV Cables on DCs: Sense-A2, Guard-A3 and Field-A4  | ||
| + | {| border="1" cellpadding="20" cellspacing="0"  | ||
| + | |-  | ||
| + | | HV Chan   | ||
| + | | Description  | ||
| + | |-  | ||
| + | | N470 Ch 0 || Drift Chamber Sense  | ||
| + | |-  | ||
| + | | N470 Ch 1 || Drift Chamber field  | ||
| + | |-  | ||
| + | | N470 Ch 2 || Drift Chamber guard  | ||
| + | |-  | ||
| + | | N470 Ch 3 || nothing  | ||
| + | |-  | ||
| + | | N471 Ch A || R1 drift  | ||
| + | |-  | ||
| + | | N471 Ch B|| R1 foil  | ||
| + | |-  | ||
| + | | N471 Ch A || Front and read PMTs  | ||
| + | |}  | ||
| + | <br>  | ||
| + | HV cables on scintillators: Front && rear PMTs-A8. Hv settings 1150 Volts(works). In counting room front-A1(BNC) and rear-A2(BNC).  | ||
| + | |||
| + | Plan: A3 should be gate. A4 - Start for TDC. A12-trigger.  | ||
| + | |||
| + | HV Settings on drift chambers S:F:G=1400:-700:980  | ||
| + | |||
| + | = Setup TIming=  | ||
| + | |||
| + | |||
| + | |||
| + | Accelerator sends the Gun gate to HRRL counting room on channel BM  | ||
| + | |||
| + | The accelerator Gun gate starts our Stanford pulse generator.  | ||
| + | |||
| + | ;The Stanford pulse generator outputs 2 pulses  | ||
| + | :one pulse is for the ADC gate and G1 trigger for V1495  | ||
| + | :The second pulse create a trigger for the DAQ  | ||
| + | |||
| + | = Singles scaler counts=  | ||
| + | |||
| + | {| border="1" cellpadding="20" cellspacing="0"  | ||
| + | |-  | ||
| + | | Run Number   | ||
| + | | Distance to Metallica's Feedthrough tip (cm)  | ||
| + | | Metalica scaler counts scaler ch 4  | ||
| + | | Plastika Scaler Counts scaler ch 1  | ||
| + | | Rear PMT + Front PMT + Gun Pulse  Counts Scaler Ch 8  | ||
| + | |HV S:F:G  | ||
| + | | Discriminator (mV)  | ||
| + | | Metalica counts/PMT+Gun pulse  | ||
| + | |-  | ||
| + | | 1|| 0 ||162 || 0 || 1004|| 1400:-700:980 || 50 || 0.16  | ||
| + | |-  | ||
| + | | 2|| 19.05 (middle) ||190 ||0 || 1146|| 1400:-700:980 || 50 || 0.17  | ||
| + | |-  | ||
| + | | 3|| 19.05 (middle) ||38 || 0|| 1072|| 0:0:0 ||50 || 0.04  | ||
| + | |-  | ||
| + | | 4|| 10.16  || 155 || 0 || 1020 || 1400:-700:980 ||50 || 0.15  | ||
| + | |-  | ||
| + | | 5|| -7.62 || 40 || 0 || 1053 || 1400:-700:980 || 50 || 0.037  | ||
| + | |-  | ||
| + | | 6|| 7.62 || 154 || 0 || 1041 || 1400:-700:980 || 50 || 0.15  | ||
| + | |-  | ||
| + | | 7|| 5.08 || 173 || 0 || 1229 || 1400:-700:980 || 50 || 0.14  | ||
| + | |-  | ||
| + | | 8|| 2.54 || 138 || 0 || 1091 || 1400:-700:980 || 50 || 0.13  | ||
| + | |-  | ||
| + | | 9|| 1 || 141 || 0 || 1045 || 1400:-700:980 || 50 || 0.13  | ||
| + | |-  | ||
| + | | 10|| 0.5 || 139 ||  || 1100 || 1400:-700:980 || 50 || 0.13  | ||
| + | |-  | ||
| + | | 11|| 0.25 || 289 ||  ||  2120|| 1400:-700:980 || 50 || 0.14  | ||
| + | |-  | ||
| + | | 12||  ||  ||  ||  || 1400:-700:980 || 50 ||   | ||
| + | |-  | ||
| + | | 13||  ||  ||  ||  || 1400:-700:980 || 50 ||   | ||
| + | |-  | ||
| + | |}  | ||
| + | |||
| + | |||
| + | = ADC + Scaler=  | ||
| + | |||
| + | {| border="1" cellpadding="20" cellspacing="0"  | ||
| + | |-  | ||
| + | | Run Number   | ||
| + | | Distance to Metallica's Feedthrough tip (cm)  | ||
| + | | Metalica scaler counts scaler ch 4  | ||
| + | | Plastika Scaler Counts scaler ch 1  | ||
| + | | Rear PMT + Front PMT + Gun Pulse  Counts Scaler Ch 8  | ||
| + | |HV S:F:G  | ||
| + | | Discriminator (mV)  | ||
| + | | Metalica counts/PMT+Gun pulse  | ||
| + | |-  | ||
| + | | 1251|| 0.25 || 967|| 0 || 23594|| 1400:-700:980 || 50 || 0.04  | ||
| + | |-  | ||
| + | | 1252|| -1 ||224 || 0 ||1554 || 1400:-700:980 || 50 || 0.14  | ||
| + | |-  | ||
| + | | 1253|| -4 ||  164|| 0 || 1074|| 1400:-700:980 || 50 || 0.15  | ||
| + | |-  | ||
| + | | 1254|| -7 || 93 || 0 ||  1274|| 1400:-700:980 || 50 ||   | ||
| + | |-  | ||
| + | | 1255|| -10 || 54 || 0 || 1075 || 1400:-700:980 || 50 || 0.05  | ||
| + | |-  | ||
| + | | 1256|| -10 || 52 || 0 || 1047 || 1400:-700:980 || 50 || cut current in half from 30 ma to 14 ma peak  | ||
| + | |-  | ||
| + | | 1257|| 19 ||94 || 0 ||  1029|| 1400:-700:980 || 50 || cut current in half from 30 ma to 14 ma peak  | ||
| + | |}  | ||
| + | |||
| + | |||
| + | tasks:  | ||
| + | |||
| + | hook up TDC done, only for metalica  | ||
| + | |||
| + | plastika, done, works  | ||
| + | |||
| + | make collimator bigger, done  | ||
| + | |||
| + | GEM readout  | ||
| + | |||
| + | TTL gate pulse to G1  | ||
| + | |||
| + | install GEM MCLK  | ||
| + | |||
[http://wiki.iac.isu.edu/index.php/Mini-prototype#HRRL_runs] [[Mini-prototype#HRRL_runs]]  | [http://wiki.iac.isu.edu/index.php/Mini-prototype#HRRL_runs] [[Mini-prototype#HRRL_runs]]  | ||
Latest revision as of 12:41, 31 July 2009
Default HRRL running Conditions
| Pulse Width | Rep Rate | Energy | |
| 8 mA | 100 ns | 1 Hz | 3 MeV | 
cable names
| CH ID | Description | 
| 2223A1 | Front Scintillator | 
| 2223A2 | Rear Scintilaltor | 
| 2223A3 | ADC Gate From counting house to Experimental Cell | 
| 2223A4 | TDC start pulse from counting house to experimental cell | 
| 2223A5 | Coincidenc between front + rear Scint + Gun pulser to scaler channel 8 | 
| 2223A6 | Metalica sense wire 4 | 
| 2223A7 | G0 MCLK for | 
| 2223A8 | Plastica sense wire 4 | 
| 2223A9 | scaler channel 4 | 
| 2223A10 | Front scintillator to ADC | 
| 2223A11 | scaler channel 1 | 
| 2223A12 | DAQ trigger | 
HV Cables on DCs: Sense-A2, Guard-A3 and Field-A4
| HV Chan | Description | 
| N470 Ch 0 | Drift Chamber Sense | 
| N470 Ch 1 | Drift Chamber field | 
| N470 Ch 2 | Drift Chamber guard | 
| N470 Ch 3 | nothing | 
| N471 Ch A | R1 drift | 
| N471 Ch B | R1 foil | 
| N471 Ch A | Front and read PMTs | 
HV cables on scintillators: Front && rear PMTs-A8. Hv settings 1150 Volts(works). In counting room front-A1(BNC) and rear-A2(BNC).
Plan: A3 should be gate. A4 - Start for TDC. A12-trigger.
HV Settings on drift chambers S:F:G=1400:-700:980
Setup TIming
Accelerator sends the Gun gate to HRRL counting room on channel BM
The accelerator Gun gate starts our Stanford pulse generator.
- The Stanford pulse generator outputs 2 pulses
 - one pulse is for the ADC gate and G1 trigger for V1495
 - The second pulse create a trigger for the DAQ
 
Singles scaler counts
| Run Number | Distance to Metallica's Feedthrough tip (cm) | Metalica scaler counts scaler ch 4 | Plastika Scaler Counts scaler ch 1 | Rear PMT + Front PMT + Gun Pulse Counts Scaler Ch 8 | HV S:F:G | Discriminator (mV) | Metalica counts/PMT+Gun pulse | 
| 1 | 0 | 162 | 0 | 1004 | 1400:-700:980 | 50 | 0.16 | 
| 2 | 19.05 (middle) | 190 | 0 | 1146 | 1400:-700:980 | 50 | 0.17 | 
| 3 | 19.05 (middle) | 38 | 0 | 1072 | 0:0:0 | 50 | 0.04 | 
| 4 | 10.16 | 155 | 0 | 1020 | 1400:-700:980 | 50 | 0.15 | 
| 5 | -7.62 | 40 | 0 | 1053 | 1400:-700:980 | 50 | 0.037 | 
| 6 | 7.62 | 154 | 0 | 1041 | 1400:-700:980 | 50 | 0.15 | 
| 7 | 5.08 | 173 | 0 | 1229 | 1400:-700:980 | 50 | 0.14 | 
| 8 | 2.54 | 138 | 0 | 1091 | 1400:-700:980 | 50 | 0.13 | 
| 9 | 1 | 141 | 0 | 1045 | 1400:-700:980 | 50 | 0.13 | 
| 10 | 0.5 | 139 | 1100 | 1400:-700:980 | 50 | 0.13 | |
| 11 | 0.25 | 289 | 2120 | 1400:-700:980 | 50 | 0.14 | |
| 12 | 1400:-700:980 | 50 | |||||
| 13 | 1400:-700:980 | 50 | 
ADC + Scaler
| Run Number | Distance to Metallica's Feedthrough tip (cm) | Metalica scaler counts scaler ch 4 | Plastika Scaler Counts scaler ch 1 | Rear PMT + Front PMT + Gun Pulse Counts Scaler Ch 8 | HV S:F:G | Discriminator (mV) | Metalica counts/PMT+Gun pulse | 
| 1251 | 0.25 | 967 | 0 | 23594 | 1400:-700:980 | 50 | 0.04 | 
| 1252 | -1 | 224 | 0 | 1554 | 1400:-700:980 | 50 | 0.14 | 
| 1253 | -4 | 164 | 0 | 1074 | 1400:-700:980 | 50 | 0.15 | 
| 1254 | -7 | 93 | 0 | 1274 | 1400:-700:980 | 50 | |
| 1255 | -10 | 54 | 0 | 1075 | 1400:-700:980 | 50 | 0.05 | 
| 1256 | -10 | 52 | 0 | 1047 | 1400:-700:980 | 50 | cut current in half from 30 ma to 14 ma peak | 
| 1257 | 19 | 94 | 0 | 1029 | 1400:-700:980 | 50 | cut current in half from 30 ma to 14 ma peak | 
tasks:
hook up TDC done, only for metalica
plastika, done, works
make collimator bigger, done
GEM readout
TTL gate pulse to G1
install GEM MCLK