Difference between revisions of "HRRL 7-30-09"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
| Line 85: | Line 85: | ||
= Singles scaler counts=  | = Singles scaler counts=  | ||
| + | {| border="1" cellpadding="20" cellspacing="0"  | ||
| + | |-  | ||
| + | | Run Number   | ||
| + | | Distance to Endplate (cm)  | ||
| + | | Metalica scaler counts  | ||
| + | | Plastica Scaler Counts  | ||
| + | |HV S:F:G  | ||
| + | |-  | ||
| + | | 1|| 0 | | 1400:-700:980  | ||
| + | |-  | ||
| + | |}  | ||
[http://wiki.iac.isu.edu/index.php/Mini-prototype#HRRL_runs] [[Mini-prototype#HRRL_runs]]  | [http://wiki.iac.isu.edu/index.php/Mini-prototype#HRRL_runs] [[Mini-prototype#HRRL_runs]]  | ||
Revision as of 17:25, 30 July 2009
Default HRRL running Conditions
| Pulse Width | Rep Rate | Energy | |
| 8 mA | 100 ns | 1 Hz | 3 MeV | 
cable names
| CH ID | Description | 
| 2223A1 | Front Scintillator | 
| 2223A2 | Rear Scintilaltor | 
| 2223A3 | ADC Gate From counting house to Experimental Cell | 
| 2223A4 | TDC start pulse from counting house to experimental cell | 
| 2223A5 | |
| 2223A6 | Metalica sense wire 4 | 
| 2223A7 | G0 MCLK for | 
| 2223A8 | Plastica sense wire 4 | 
| 2223A9 | scaler channel 4 | 
| 2223A10 | Front scintillator to ADC | 
| 2223A11 | scaler channel 1 | 
| 2223A12 | DAQ trigger | 
HV Cables on DCs: Sense-A2, Guard-A3 and Field-A4
| HV Chan | Description | 
| N470 Ch 0 | Drift Chamber Sense | 
| N470 Ch 1 | Drift Chamber field | 
| N470 Ch 2 | Drift Chamber guard | 
| N470 Ch 3 | nothing | 
| N471 Ch A | R1 drift | 
| N471 Ch B | R1 foil | 
| N471 Ch A | Front and read PMTs | 
HV cables on scintillators: Front && rear PMTs-A8. Hv settings 1150 Volts(works). In counting room front-A1(BNC) and rear-A2(BNC).
Plan: A3 should be gate. A4 - Start for TDC. A12-trigger.
HV Settings on drift chambers S:F:G=1400:-700:980
Setup TIming
Accelerator sends the Gun gate to HRRL counting room on channel BM
The accelerator Gun gate starts our Stanford pulse generator.
- The Stanford pulse generator outputs 2 pulses
 - one pulse is for the ADC gate and G1 trigger for V1495
 - The second pulse create a trigger for the DAQ
 
Singles scaler counts
| Run Number | Distance to Endplate (cm) | Metalica scaler counts | Plastica Scaler Counts | HV S:F:G | 
| 1 | | 1400:-700:980 |