Difference between revisions of "CHIPS IAC Run 5-29-08"
Jump to navigation
Jump to search
Line 35: | Line 35: | ||
Accelerator Gun problem (ground wire shielding was worn away and creating path for short) | Accelerator Gun problem (ground wire shielding was worn away and creating path for short) | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
+ | Restore tune with settings below.: | ||
{| border="1" |cellpadding="20" cellspacing="0 | {| border="1" |cellpadding="20" cellspacing="0 | ||
Line 80: | Line 75: | ||
|- | |- | ||
|SOL2 || 0.40 | |SOL2 || 0.40 | ||
+ | |} | ||
+ | |||
+ | {| border="1" |cellpadding="20" cellspacing="0 | ||
+ | |- | ||
+ | |Run # || MPA file name || W || Ta || Description | ||
+ | |- | ||
+ | |56|| NaI056.mpa || IN || In|| Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 48<math>\pm</math> 8 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV. | ||
|} | |} | ||
[http://www.iac.isu.edu/mediawiki/index.php/CHIPS_Run_May-2008 Go Back] | [http://www.iac.isu.edu/mediawiki/index.php/CHIPS_Run_May-2008 Go Back] |
Revision as of 15:41, 29 May 2008
Calibration
Run # | MPA file name | Description |
40 | NaI040.mpa | Na-22 source in front of HpGe and Co-60 on top of NaI detector |
41 | NaI019.mpa | Co-60 source in front of HpGe and Na-22 on top of NaI detector |
Last Dipole Sweep
Tune 10 Mev onto Tungsten and 4 MeV into Cell
We put in two thin pieces (thickness ~1/4" each) making a ~1/2" of lead angled at ~30 degrees wrt vertical between the NaI detector and the collimator to cut down on low-energy (< 200 keV) photons.
Run # | MPA file name | W | Ta | Description |
45 | NaI045.mpa | IN | IN | Dipole at 2 MeV (0.78 on Pot), 60 Hz rep rate |
46 | NaI046.mpa | IN | IN | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 116 | 15 counts at 500 keV, Live=929 seconds
47 | NaI047.mpa | IN | Out | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 53 | 9 counts at 500 keV, Live=607 seconds, (Tant IN/Out ratio =116/53 607/929 = 1.4)
48 | NaI048.mpa | IN | Out | Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 90 | 11 counts at 500 keV, Live=600 seconds, ignore NaI (cable not plugged into scope)
49 | NaI049.mpa | IN | In | Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 113 | 12 counts at 500 keV, Live=634 seconds,plugged NaI cable back into scope in middle of run. ((Tant IN/Out ratio =113/90 = 1.26 )
Accelerator Gun problem (ground wire shielding was worn away and creating path for short)
Restore tune with settings below.:
Device | setting |
RS1 | 0+ |
RS2 | 0- |
FS1 | 0+ |
FS2 | 0- |
0Q1 | -0.20 |
0Q2 | +2.86 |
45Q1 | -0.004 |
45Q2 | +2.24 |
L90Q1 | -1.33 |
L90Q2 | +2.42 |
Bend1 | 3.5 |
Bend2 | 0.86 |
Gun HV | 13 kV |
Grid | 2.31 |
802 | 16 kV |
SOL1 | 0.39 |
SOL2 | 0.40 |
Run # | MPA file name | W | Ta | Description |
56 | NaI056.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 48 | 8 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.