PbF2 CrystalNumber18: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Oborn (talk | contribs)
Oborn (talk | contribs)
 
(9 intermediate revisions by the same user not shown)
Line 14: Line 14:
|beam start: || 10:42
|beam start: || 10:42
|-
|-
|beam stop: ||  
|beam stop: || 12:42
|}
|}


Line 42: Line 42:


@12:36 [[Image:Pulseblock181236.JPG | 200 px]]
@12:36 [[Image:Pulseblock181236.JPG | 200 px]]
Before: [[Image:DSCF1552.JPG | 400 px]] After: [[Image:DSCF1556.JPG | 400 px]]


;Dose rate measurements (@1255 hours)
;Dose rate measurements (@1255 hours)
Line 49: Line 52:
| <math>\beta</math>-radiation: ||  500 uR/hr
| <math>\beta</math>-radiation: ||  500 uR/hr
|}
|}
;Transparency Measurements (@1525 hours)
[[Image:Block18.JPG || 500 px]] [[Image:Block18@90deg.JPG || 500 px]]


=12/5/07=
=12/5/07=
;Transparency measurement (1235)
;Accelerator Settings
{| border="1"
| beam energy || 20 MeV
|-
| Rep Rate: ||  30 Hz
|-
| I_peak:    || 60 mA/pulse
|-
| pulse width:|| 0.1 <math>\mu</math>s (100 ns)
|-
|beam start: || 12:54
|-
|beam stop: || 14:55
|}
;Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt <math>\times</math> ns
@ 13:05 [[Image:Block18 1.05pm.JPG | 200 px]]
@ 13:15 [[Image:Block18 1.15pm.JPG | 200 px]]
@ 13:25 [[Image:Block18 1.25pm.JPG | 200 px]]
@ 13:35 [[Image:Block18 1.35pm.JPG | 200 px]]
@ 13:45 [[Image:Block18 1.45pm.JPG | 200 px]]
@ 13:55 [[Image:Block18 1.55pm.JPG | 200 px]]
@ 14:05 [[Image:Block18 2.05pm.JPG | 200 px]]
@ 14:15 [[Image:Block18 2.15pm.JPG | 200 px]]
@ 14:25 [[Image:Block18 2.25pm.JPG | 200 px]]
@ 14:35 [[Image:Block18 2.35pm.JPG | 200 px]]
@ 14:45 [[Image:Block18 2.45pm.JPG | 200 px]]
@ 14:55 [[Image:Block18 2.55pm.JPG | 200 px]]
;Dose rate measurements (@1457 hours)
{| border="1"
| <math>\gamma</math>-radiation ||  5 mR/hr
|-
| <math>\beta</math>-radiation: ||  10 mR/hr
|}




[http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back]
[http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back]

Latest revision as of 22:39, 5 December 2007

Below are the resulting transparency measurements for PbF2 block # 18

12/4/07

Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns)
beam start: 10:42
beam stop: 12:42
Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)

O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns

@10:43

@11:01

@11:16

@11:31

@11:43

@11:53

@11:53

@12:03

@12:13

@12:23

@12:36

Before: After:


Dose rate measurements (@1255 hours)
[math]\displaystyle{ \gamma }[/math]-radiation 500 uR/hr
[math]\displaystyle{ \beta }[/math]-radiation: 500 uR/hr


Transparency Measurements (@1525 hours)

12/5/07

Transparency measurement (1235)


Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns)
beam start: 12:54
beam stop: 14:55
Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)

O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns


@ 13:05

@ 13:15

@ 13:25

@ 13:35

@ 13:45

@ 13:55

@ 14:05

@ 14:15

@ 14:25

@ 14:35

@ 14:45

@ 14:55


Dose rate measurements (@1457 hours)
[math]\displaystyle{ \gamma }[/math]-radiation 5 mR/hr
[math]\displaystyle{ \beta }[/math]-radiation: 10 mR/hr



Go Back