Below are the resulting transparency measurements for PbF2 block # 18
12/4/07
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 10:42 |
beam stop: | 12:42 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns
- Dose rate measurements (@1255 hours)
-radiation | 500 uR/hr |
-radiation: | 500 uR/hr |