Line 15: Line 15:
 
| Length of Target (cm)  || 1 || 1 || 5 ||5 ||5
 
| Length of Target (cm)  || 1 || 1 || 5 ||5 ||5
 
|-
 
|-
| <math>N_{incident}</math> || 4E7 ||4E8 || 6E6 ||6E7 || 6E7
+
| <math>N_{incident}(Total)</math> || 4E7 ||4E8 || 6E6 ||6E7 || 6E7
 
|-
 
|-
| <math>N_{events}</math> || 1026940 || 10270829|| ||4826141 || 1001700
+
| <math>N_{events}(Total)</math> || 1026940 || 10270829|| 771161 ||4826141 || 1001700
 
|-
 
|-
| <math>N_{Moller}</math> || 975593 || 9757288|| ||4584834 || 951138
+
| <math>N_{events}(5^{\circ}-40^{\circ})</math> || 305570 || 3054080|| 229266|| ||  
 
|-
 
|-
| <math>t_{simulated}</math> (s) || 1.3E-5 ||1.3E-4 || ||9.62E-5 ||9.54E-5
+
| <math>N_{Moller}(Total)</math> || 975593 || 9757288|| 732603||4584834 || 951138
 
|-
 
|-
| Event Cross-Section (b) || 0.61 || 0.61|| ||0.38 || 0.079
+
| <math>N_{Moller}(5^{\circ}-40^{\circ})</math> ||290291  || 2901376|| 217803|| 1362098||  
 
|-
 
|-
| Total Moller Cross-Section (b) || 0.58||0.58 || ||0.361 || 0.075
+
| <math>t_{simulated}(Total)</math> (s) || 1.3E-5 ||1.3E-4 || 9.57E-6||9.62E-5 ||9.54E-5
 
|-
 
|-
| Individual Moller Cross-Section (b) || 5.95E-7 || 5.94E-8 || ||7.87E-8 ||7.88E-8
+
| Total Event Cross-Section (b) || 0.61 || 0.61|| 0.61 ||0.38 || 0.079
 
|-
 
|-
| Moller event rate per barn (<math>b^{-1}</math>)|| 1.68E6 || 1.68E6 || ||1.27E7 || 1.27E7
+
| Total Moller Cross-Section (b) || 0.58||0.58 || 0.58 ||0.361 || 0.075
 +
|-
 +
| Detector Event Cross-Section (b) || 0.18 || 0.18|| 0.18 || ||  
 +
|-
 +
| Detector Moller Cross-Section (b) ||0.17 ||0.17 ||0.17  || ||
 
|}
 
|}
  
  
 
Total dectector events occur for about 2.5% of the incident electrons on a LH2 target.  We can assume that the Moller rate is 95% of the total event rate.  We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well.  Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material
 
Total dectector events occur for about 2.5% of the incident electrons on a LH2 target.  We can assume that the Moller rate is 95% of the total event rate.  We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well.  Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material
 +
 +
 +
[[File:Cross_Section.png]]
  
 
If we were to integrate the Moller Differential Cross Section
 
If we were to integrate the Moller Differential Cross Section
 +
 +
[[File:6e7incLH2_MolDiffXSect.png]]
 +
 +
[[File:Screen_Shot_2018-03-29_at_8.57.34_AM.png]]

Latest revision as of 18:21, 30 March 2018

[math]\textbf{Navigation}[/math]

[math]\vartriangleleft [/math] [math]\triangle [/math] [math]\vartriangleright [/math]


Rates
Simulation GEANT4(1cm target) GEANT4(1cm target) GEANT4(5cm target) GEANT4(5cm target) Whitney
Length of Target (cm) 1 1 5 5 5
[math]N_{incident}(Total)[/math] 4E7 4E8 6E6 6E7 6E7
[math]N_{events}(Total)[/math] 1026940 10270829 771161 4826141 1001700
[math]N_{events}(5^{\circ}-40^{\circ})[/math] 305570 3054080 229266
[math]N_{Moller}(Total)[/math] 975593 9757288 732603 4584834 951138
[math]N_{Moller}(5^{\circ}-40^{\circ})[/math] 290291 2901376 217803 1362098
[math]t_{simulated}(Total)[/math] (s) 1.3E-5 1.3E-4 9.57E-6 9.62E-5 9.54E-5
Total Event Cross-Section (b) 0.61 0.61 0.61 0.38 0.079
Total Moller Cross-Section (b) 0.58 0.58 0.58 0.361 0.075
Detector Event Cross-Section (b) 0.18 0.18 0.18
Detector Moller Cross-Section (b) 0.17 0.17 0.17


Total dectector events occur for about 2.5% of the incident electrons on a LH2 target. We can assume that the Moller rate is 95% of the total event rate. We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well. Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material


Cross Section.png

If we were to integrate the Moller Differential Cross Section

6e7incLH2 MolDiffXSect.png

Screen Shot 2018-03-29 at 8.57.34 AM.png