Difference between revisions of "Comparison of GEANT Simulation to Whitney Data"

From New IAC Wiki
Jump to navigation Jump to search
Line 8: Line 8:
  
  
<center>{| class="wikitable" align="center" border=1
+
{| class="wikitable" align=center border=1
 
|+ '''Rates'''
 
|+ '''Rates'''
 
|-
 
|-
Line 26: Line 26:
 
|-
 
|-
 
| N_{incident} || 4E7 ||4E8 ||6E7 || 6E7
 
| N_{incident} || 4E7 ||4E8 ||6E7 || 6E7
|}</center>
+
|}
  
  
 
Total dectector events occur for about 2.5% of the incident electrons on a LH2 target.  We can assume that the Moller rate is 95% of the total event rate.  We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well.  Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material
 
Total dectector events occur for about 2.5% of the incident electrons on a LH2 target.  We can assume that the Moller rate is 95% of the total event rate.  We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well.  Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material

Revision as of 16:54, 26 March 2018

[math]\textbf{Navigation}[/math]

[math]\vartriangleleft [/math] [math]\triangle [/math] [math]\vartriangleright [/math]


Rates
Simulation GEANT4(1cm target) GEANT4(1cm target) GEANT4(5cm target) Whitney
Event Cross-Section (b) 0.61 0.61 0.38 0.079
Moller Cross-Section (b) 0.58 0.58 0.361 0.075
Length of Target (cm) 1 1 5 5
t_{simulated} (s) 1.3E-5 1.3E-4 9.8E-4 9.54E-5
N_{events} 1026940 10270829 4826141 1001700
N_{Moller} 975593 9757288 4584834 951138
N_{incident} 4E7 4E8 6E7 6E7


Total dectector events occur for about 2.5% of the incident electrons on a LH2 target. We can assume that the Moller rate is 95% of the total event rate. We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well. Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material