Difference between revisions of "Gain matching"
Jump to navigation
Jump to search
m (moved Rates and gain matching to Gain matching) |
|
(No difference)
| |
Latest revision as of 07:15, 18 August 2016
7/17/16
Information about the run setup can be seen here (thresholds, source positioning, ect).
Each PMT was individually placed in coincidence with a trigger at the center of the room. High voltage was then adjusted on each PMT until all rates were equal.
| Detector | PMT | High voltage | |
|---|---|---|---|
| angle | color | ||
| 30 | Red | Top | -1424 |
| Bot | -1458 | ||
| 90 | Yellow | Top | -1690 |
| Bot | -1597 | ||
| 150 | Blue | Top | -1553 |
| Bot | -1595 | ||
| 225 | wood | Top | -1700 |
| Bot | -1678 | ||