Difference between revisions of "04-22-2015"

From New IAC Wiki
Jump to navigation Jump to search
Line 97: Line 97:
 
Run 4555 had a discriminator threshold set to 20 mV and the terminators were out.  DAQ rate is 650 Hz. Pu-Be source in, moved away from the detector by 52".
 
Run 4555 had a discriminator threshold set to 20 mV and the terminators were out.  DAQ rate is 650 Hz. Pu-Be source in, moved away from the detector by 52".
  
[[File:r4555_fake_stop.png | 500 px]]
+
{| cellpadding="2" style="border: 1px solid darkgray;"
 
+
|- border="0"
[[File:r4555_det4_up.png | 500 px]]
+
| [[File:r4555_fake_stop.png|340px|Region 1]]
 
+
| [[File:r4555_det4_up.png|340px|Region 2]]
 +
|- align="center"
 +
| Fake stop|| Second hit
 +
|}
  
 
Run 4556 had a discriminator threshold set to 10 mV and the terminators were out.  DAQ rate is 1400 Hz. Pu-Be source in, moved away from the detector by 52".
 
Run 4556 had a discriminator threshold set to 10 mV and the terminators were out.  DAQ rate is 1400 Hz. Pu-Be source in, moved away from the detector by 52".
  
[[File:r4556_fake_stop.png | 500 px]]
+
{| cellpadding="2" style="border: 1px solid darkgray;"
 
+
|- border="0"
[[File:r4556_det4_up.png | 500 px]]
+
| [[File:r4556_fake_stop.png|340px|Region 1]]
 +
| [[File:r4556_det4_up.png|340px|Region 2]]
 +
|- align="center"
 +
| Fake stop|| Second hit
 +
|}
  
 
Run 4557 had a discriminator threshold set to 10 mV and the terminators were in.  DAQ rate is 1400 Hz. Pu-B source in, moved away from the detector by 52".
 
Run 4557 had a discriminator threshold set to 10 mV and the terminators were in.  DAQ rate is 1400 Hz. Pu-B source in, moved away from the detector by 52".
  
[[File:r4557_fake_stop.png | 500 px]]
+
{| cellpadding="2" style="border: 1px solid darkgray;"
 +
|- border="0"
 +
| [[File:r4557_fake_stop.png|340px|Region 1]]
 +
| [[File:r4557_det4_up.png|340px|Region 2]]
 +
|- align="center"
 +
| Fake stop|| Second hit
 +
|}
  
[[File:r4557_det4_up.png | 500 px]]
 
  
 
  PMT detector #4 HV at -1400 Volts
 
  PMT detector #4 HV at -1400 Volts
Line 118: Line 130:
 
Run 4558 had a discriminator threshold set to 10 mV and the terminators were in.  DAQ rate is 4670 Hz. Pu-Be source in, moved away from the detector by 52".
 
Run 4558 had a discriminator threshold set to 10 mV and the terminators were in.  DAQ rate is 4670 Hz. Pu-Be source in, moved away from the detector by 52".
  
[[File:r4558_fake_stop.png | 500 px]]
+
{| cellpadding="2" style="border: 1px solid darkgray;"
 
+
|- border="0"
[[File:r4558_det4_up.png | 500 px]]
+
| [[File:r4558_fake_stop.png|340px|Region 1]]
 +
| [[File:r4558_det4_up.png|340px|Region 2]]
 +
|- align="center"
 +
| Fake stop|| Second hit
 +
|}
  
 
Run 4559 had a discriminator threshold set to 10 mV and the terminators were in.  DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".
 
Run 4559 had a discriminator threshold set to 10 mV and the terminators were in.  DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".
  
[[File:r4559_fake_stop.png | 500 px]]
+
{| cellpadding="2" style="border: 1px solid darkgray;"
 
+
|- border="0"
[[File:r4559_det4_up.png | 500 px]]
+
| [[File:r4559_fake_stop.png|340px|Region 1]]
 +
| [[File:r4559_det4_up.png|340px|Region 2]]
 +
|- align="center"
 +
| Fake stop|| Second hit
 +
|}
  
 
Run 4560 had a discriminator threshold set to 10 mV and the terminators were out.  DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".
 
Run 4560 had a discriminator threshold set to 10 mV and the terminators were out.  DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".
  
[[File:r4560_fake_stop.png | 500 px]]
+
{| cellpadding="2" style="border: 1px solid darkgray;"
 
+
|- border="0"
[[File:r4560_det4_up.png | 500 px]]
+
| [[File:r4560_fake_stop.png|340px|Region 1]]
 +
| [[File:r4560_det4_up.png|340px|Region 2]]
 +
|- align="center"
 +
| Fake stop|| Second hit
 +
|}
  
 
Run 4561 had a discriminator threshold set to 10 mV and the terminators were out.  DAQ rate is 200 Hz. Cosmic rays test.
 
Run 4561 had a discriminator threshold set to 10 mV and the terminators were out.  DAQ rate is 200 Hz. Cosmic rays test.
  
[[File:r4561_fake_stop.png | 500 px]]
+
{| cellpadding="2" style="border: 1px solid darkgray;"
 
+
|- border="0"
[[File:r4561_det4_up.png | 500 px]]
+
| [[File:r4561_fake_stop.png|340px|Region 1]]
 
+
| [[File:r4561_det4_up.png|340px|Region 2]]
 
+
|- align="center"
 +
| Fake stop|| Second hit
 +
|}
  
 
;1.8 g Pu-Be source should be used next time
 
;1.8 g Pu-Be source should be used next time

Revision as of 19:43, 25 April 2015

Pu-Be source test

PMT detector #4 HV at -1000 Volts

Pu-Be 18 gram source# M1197

Run 4546 had a discriminator threshold set to 80 mV and the terminators were out. Cosmic rays test.

Region 1 Region 2
Fake stop Second hit

Run 4547 had a discriminator threshold set to 80 mV and the terminators were out. DAQ rate is 100 Hz. Pu-Be source in.

Region 1 Region 2
Fake stop Second hit

Run 4548 had a discriminator threshold set to 80 mV and the terminators were in. DAQ rate is 100 Hz. Pu-Be source in.

Region 1 Region 2
Fake stop Second hit

Run 4549 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 2800 Hz. Pu-B source in.

Region 1 Region 2
Fake stop Second hit

Run 4550 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 2800 Hz. Pu-B source in.

Region 1 Region 2
Fake stop Second hit

Run 4551 had a discriminator threshold set to 40 mV and the terminators were out. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26".

Region 1 Region 2
Fake stop Second hit

Run 4552 had a discriminator threshold set to 40 mV and the terminators were in. DAQ rate is 500 Hz. Pu-B source in, moved away from the detector by 26".

Region 1 Region 2
Fake stop Second hit

Run 4553 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 1850 Hz. Pu-Be source in, moved away from the detector by 26".

Region 1 Region 2
Fake stop Second hit

Run 4554 had a discriminator threshold set to 20 mV and the terminators were in. DAQ rate is 625 Hz. Pu-Be source in, moved away from the detector by 52".

Region 1 Region 2
Fake stop Second hit

Run 4555 had a discriminator threshold set to 20 mV and the terminators were out. DAQ rate is 650 Hz. Pu-Be source in, moved away from the detector by 52".

Region 1 Region 2
Fake stop Second hit

Run 4556 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 1400 Hz. Pu-Be source in, moved away from the detector by 52".

Region 1 Region 2
Fake stop Second hit

Run 4557 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 1400 Hz. Pu-B source in, moved away from the detector by 52".

Region 1 Region 2
Fake stop Second hit


PMT detector #4 HV at -1400 Volts

Run 4558 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 4670 Hz. Pu-Be source in, moved away from the detector by 52".

Region 1 Region 2
Fake stop Second hit

Run 4559 had a discriminator threshold set to 10 mV and the terminators were in. DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".

Region 1 Region 2
Fake stop Second hit

Run 4560 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 2700 Hz. Pu-Be source in, moved away from the detector by 91".

Region 1 Region 2
Fake stop Second hit

Run 4561 had a discriminator threshold set to 10 mV and the terminators were out. DAQ rate is 200 Hz. Cosmic rays test.

Region 1 Region 2
Fake stop Second hit
1.8 g Pu-Be source should be used next time