Line 1: Line 1:
[https://wiki.iac.isu.edu/index.php/RS#Compact_and_Portable_X-Pinch_Driver go back]
 
  
 
=Progress Reports=
 
 
 
==December 08, 2013==
 
*The updated drawing of bricks with remeasured front plate's holes created (drawing #2013.1.001.0001)
 
 
==December 09, 2013==
 
*The list of possible manufacturing company for Brick's Housing (BH) parts production is established:
 
**Partner Steel Co, Inc, Pocatello;
 
**Valley Sheet Metal (VSM) Technologies, Idaho Falls;
 
**Primear Technology, Blackfoot;
 
**Northwest wire EDM, Spokane, WA;
 
**Nelson Metal Technology, Payette, ID;
 
**Water Jet Cutting, Albuquerque;
 
*All above companies have been contacted for quotes. Criteria were price and speed of production.
 
 
==December 10, 2013==
 
*Brick's Housing (BH) parts (steel/AL/PMMA sheets) drawings is approved by Spielman (drawings #2013.1.001.0002-0009)
 
 
==December 11, 2013==
 
*VSM Technologies: selected as manufactured company for BH parts (drawings #2013.1.001.0002-0009)
 
 
==December 17, 2013==
 
*BH parts arrived at IAC and inspected. Kevin is going to assemble and weld them all together.
 
 
==December 18, 2013==
 
*Cathode/anode drawings submitted to Spielman for approving (drawings #2013.1.001.0010-0017)
 
*PMMA_Output_Sheet/Charging_Isolating_Tube drawings submitted to Spielman for approving (drawings #2013.1.001.0018-0019)
 
*X-pinch driver assembly drawing with included cathode/anode submitted to Spielman for approving (drawing #2013.1.001.0020)
 
*PARKER's Viton O-rings V0769-60 2-246 (2 pcs), ID 4 1/2 and W 1/8", selected for vacuum seal inside the cathode/anode section.
 
 
==December 19, 2013==
 
*LESKER reduced 4-way cross (C-0800-275, $890) found as a candidate for vacuum chamber [http://www.lesker.com/newweb/flanges/fittings_cf_crosses.cfm?pgid=4wayreducer];
 
*LESKER reduced 4-way cross drawing downloaded and incorporated into SolidWorks (assembly file Lesker_C-800_275\C-0800-275_reassembled);
 
*LESKER reduced 4-way cross redesigned to match our x-pinch driver (drawing file Lesker_C-800_275\2013.1.001.0030);
 
 
==December 20, 2013==
 
*Some changes to parts have been done to accommodate LESKER redesigned cross:
 
**1) for Al output plate, the inner cut increased from 4.5 diameter to 10" diameter to match the cross (drawing #2013.1.001.0008);
 
**2) for anode can, the slot size increased from 0.4" to 0.5" to march x-pinch wires length  (drawing #2013.1.001.0014);
 
*Reassembled LESCER cross drawing submitted to Spielman for approving (drawing LESKER C-0800-275_REASSEMBLED)
 
*X-pinch driver assembly drawing with included cathode/anode/cross submitted to Spielman for approving (drawing #2013.1.001.0021)
 
*LESCER cross and new assembly drawings is approved by Spielman:
 
 
==December 30, 2013==
 
* LESKER reduced 4-way cross (C-0800-275, $890) is ordered [https://wiki.iac.isu.edu/index.php/File:Order_Report_from_The_Kurt_J.pdf], [http://www.lesker.com/newweb/flanges/fittings_cf_crosses.cfm?pgid=4wayreducer]. Expected delivery id January 16, 2014. Comments: this one we will cut and reassemble later in the way we need. Just to remind, I plan two use one 8" flange for plate connection, one 8" flange for x-pinch access and vacuum pump connection, one 2 3/4 flange for x-ray diagnostics and one 2 3/4 flange for x-ray output.
 
 
* for x-ray windows we  can use Beryllium window (available from Moxtek in 1-1/3 and 2-1/8 CF flanges [http://www.eurotek-general.com/upload/PDF/Moxtek/DuraBeryllium%20Windows%20in%20ConFlat%20Flanges,%20WIN-TECH-1001.pdf]).
 
[[File:Be transmission data1.jpg | 100 px]]
 
 
For 2-1/8 CF flanges x-ray window, we will need Zero-Length Reducer Flange (from 2 3/4 to 2 1/8), like [http://www.lesker.com/newweb/flanges/flanges_cf_reducer.cfm?pgid=std]
 
 
* '''can we use quartz window instead of beryllium?''' (we can probably borrow one from IAC stock);
 
* do we need RIGHT NOW x-ray window? A: no, we will need just glass viewport for x-pinch visual observation;
 
 
==December 31, 2013==
 
Other parts we need for vacuum chamber are:
 
*flanges:
 
** 8" fixed blank CF flange, Lesker part #F0800X000N, $125 [http://www.lesker.com/newweb/flanges/flanges_cf_304SS.cfm?pgid=8in]. Note: I would cut this flange in the middle to reduce the weight twice from 12 -> 6 lbs;
 
** 2 3/4" fixed bore 1.63" CF flange, Lesker part #F0275X175N, $15 [http://www.lesker.com/newweb/flanges/flanges_cf_304SS.cfm?pgid=2d75in]. Note: this flange will be used for x-ray diode's mounting;
 
** 2-3/4" CF flange viewport window. Note: this flange will be used for visual x-pinch observation. Later this flange can be replaced by x-ray window. Choose the cheapest (first) one:
 
*** Corning 7056 Glass Viewport - 2.75" CF Flange, Accu-Glass Products, $125 [https://accuglassproducts.com/product.php?productid=17478&cat=569&page=1];
 
*** Conflat Flange (CF) Zero Length Glass Viewport 1.5 inch to CF 2-3/4 inch, Ideal Vacuum Products, 179.95 [http://www.pchemlabs.com/product.asp?pid=2262];
 
*** 2 3/4" CF flange Sapphire Viewports, Lesker part #VPZL-275SW, $650 [http://www.lesker.com/newweb/flanges/viewports_cf_sapphire.cfm?pgid=0];
 
*gaskets [http://www.lesker.com/newweb/flanges/hardware_cf_gaskets.cfm?pgid=ofhc]:
 
** 1/4 Hard OFHC Copper Gasket for 2-3/4" CF flange, Lesker part #GA-0275, set of 10, $26.40;
 
** 1/4 Hard OFHC Copper Gasket for 8" CF flange, Lesker part #GA-0800, set of 10, $75.00.
 
*fasteners [http://www.lesker.com/newweb/flanges/flanges_cf_304SS.cfm?pgid=2d75in scroll down]:
 
** 5/16—24 x 2-1/4" Bolt & Nut Set, Lesker part #HBS31224225, set of 25, $37.58 (for 8" flange up);
 
** 5/16—24 x 1-3/4" Bolt Kits, Lesker part #HBK31224175, set of 25, $30.60 (for 8" flange Al plate connection), '''(need 1" length)''';
 
** 1/4—28 x 1-3/8" Bolt & Nut Set, Lesker part #HBS25028138, set of 25, $29.38 (for 2-3/4" flanges);
 
 
*Total quote is '''xxx.xx''' plus shipping.
 
 
==January 02, 2014==
 
*Al output plate drawing #2013.1.001.0008 is updated to accommodate vacuum chamber's cross (11" cut changed to 8" and added slot cuts for small flanges);
 
*Reassembled Lesker cross drawing #2013.1.001.0030 is updated (file name changed and added some dimensions for clarity);
 
*Assembly drawing #2013.1.001.0021 is updated for clarity;
 
 
==January 02, 2014==
 
'''PMMA o-ring and groove design'''
 
 
*o-ring material we are needed:
 
** Viton (V1436-75, V1475-75, V1476-75);
 
** assumption made:
 
*** viton = fluorocarbon;
 
*** hardness we nee 70-80;
 
 
*o-ring size we are needed:
 
** nominal: ID=4-1/2, OD=4-3/4, W=1/8; 
 
** actual: ID=4.484", W=0.139";
 
** Parker size number 2-246;
 
 
*o-ring we are needed:
 
** V1436-75 2-246;
 
** V1475-75 2-246;
 
** V1476-75 2-246;
 
 
*grove shape and size design:
 
** chapter 4.3, section IV - static o-ring sealing, Parker o-ring handbook.pdf:
 
*** groove shape standard;
 
*** ID=4.484", W=0.161", OD=4.806", Depth = 0.104", R=0.017", Finish = 16 RMS uinch;
 
** also see Eriks groove/o-ring calculator [http://oringcalculator.eriksgroup.com/#], pdf report [[File:03012014162515.pdf]];
 
** assumption made:
 
*** external pressure;
 
*** ID(groove) = ID (actual o-ring size);
 
*** o-ring deformation is about 25%;
 
 
* o-ring's grooves included into the PMMA drawing #2013.1.001.0018;
 
 
 
==January 07, 2014==
 
talked with R. Spielman:
 
*o-ring: the hardness of o-ring doesn't matter;
 
*gaskets:
 
** use Viton square gaskets for large flange instead of Cu, it could be used many times;
 
** cutting the large twice is OK;
 
** small flanges: using one blank and one veiwport is OK. Note: buy two blank (%15 each) and use viewport if available from IAV stock;
 
*vacuum chamber, anode, cathode drawings all are looking good;
 
 
parts we need to order extra for vacuum chamber:
 
* flanges:
 
** first look at IAC; if not available, than buy:
 
** 8" fixed blank CF flange, Lesker part #F0800X000N, $125 [http://www.lesker.com/newweb/flanges/flanges_cf_304SS.cfm?pgid=8in];
 
** 2 3/4" fixed blank CF flange, Lesker part #F0275X000N, $15 [http://www.lesker.com/newweb/flanges/flanges_cf_304SS.cfm?pgid=2d75in].
 
** Corning 7056 Glass Viewport - 2.75" CF Flange, Accu-Glass Products, $125 [https://accuglassproducts.com/product.php?productid=17478&cat=569&page=1];
 
* use Viton square o-ring to seal all flanges;
 
* fasteners, I will look at later;
 
 
 
==January 10, 2014==
 
talked with Kevin about vacuum chamber and anode/cathode:
 
 
* for vacuum chamber we need to order extra:
 
** 8" CF rotatable flange 6" pipe;
 
** 8" CF non-rotatable flange 6" pipe;
 
** 8" CF blank flange;
 
** Kevin recommended Duniway stockroom corp;
 
 
* order material (Grainger) and then we will do it at IAC;
 
** ask ParnerStill (Pocatello) about naterial, but they will probably ask what grade of brass we need;
 
 
* 8" flanges from MDC Vacuum have been ordered [https://wiki.iac.isu.edu/index.php/File:MDC_Vacuum_011014.pdf]:
 
** 8" CF blank flange, ref# F800000, $135 [http://www.mdcvacuum.com/displayproductcontent.aspx?d=MDC&p=m.1.1.9.1];
 
** 8" CF 6" ID non-rotatable flange, REF# F800600, $129, 2 parts [http://www.mdcvacuum.com/displayproductcontent.aspx?d=MDC&p=m.1.1.9.1];
 
** total $393 plus shipping
 
 
==January 13, 2014==
 
 
x-pinch fabrication update
 
 
*vacuum chamber: all parts are ordered and after its arriving we start to fabricate the vacuum chamber;
 
*cathode/anode:
 
**should be approved? yes, and also need to include current monitor in anode cane drawing;
 
**identify and buy brass cuts; use naval/hard brass, should be easy to machined and inexpensive
 
**after vacuum chamber will be fabricated, update, if needed, drawings and fabricate anode/cathode parts;
 
*AL output plate  (drawing 2013.0001.0008): need to modify;
 
*PMMA sheet output (drawing 2013.0001.0018): need to buy sheet and fabricate;
 
*charging isolating tube: need to buy rod and fabricate (how and who?)
 
*oil foamsm where to take?
 
*square viton o-ring: look at MDC Vacuum, or call them and ask for square Viton o=rinf for 8" flange
 
 
 
'''Found mistake in fabrication the Al output plate: the central whole is centered in all direction, but should not be. Need to make update of all drawings to reflect this fact;'''
 
 
*AL output plate drawing 2013.0001.0008 is updated to reflect real cut made in Al plate  ('''done''');
 
 
 
*Anode/cathode drawings need to be modified to reflect real cut made in Al plate  ('''done'''):
 
*bricks has a freedom inside, mostly in horizontal directions. How we center cathode vs anode:
 
**make as reference plates the bottom and front of housing and update cathode plate drawing 2013.0001.0010 to center cathode vs anode;
 
**need some extra parts (tube ID=2" OD=2.5") for centering;
 
*where to include second current monitor?
 
**in anode can drawing 2013.0001.0010;
 
**make anode can thicker to have extra space for diagnostic mounting;
 
 
 
*Output PMMA plate need to be modified to reflect real cut made in Al plate  ('''done''');
 
 
==January 15, 2014==
 
 
 
'''Found that housing plastic sheets we ordered do not have precise thikness we asked and wanted:'''
 
*They are really 0.45-0.49" and 0.23-0.235" instead of 1/2 and 1/4 as we expected to be;
 
*Most likely that plastic supply companies switched to metrics (mm) standard. But they still specify thickness in inches, but real thickness is less, like 0.47" instead of 0.5". Some company specify this fact [http://www.eplastics.com/Plexiglass_Acrylic_Sheet_Clear];
 
*Found company which probably still supply plastic in inches we need [http://www.professionalplastics.com/];
 
 
 
Ordered plastic sheets (housing side's isolating and housing output isolating) and HDPE rod:
 
* Professional Plastics.com [http://www.professionalplastics.com/];
 
* Order summary [https://wiki.iac.isu.edu/index.php/File:Professional_Plastics_Order_(59910).pdf];
 
* Hopefully they will have precisely the same thickness and diameter as we want, but not the different thickness as happened before;
 
 
 
*Charging Isolating Tube have been modified to accommodate new two lines design ('''done''');
 
 
 
==January 16, 2014==
 
 
*Anode/cathode brass cuts have been ordered:
 
**we need naval brass, like C464, or any hard brass. Should have a property of good machining and be also cheap;
 
**sheet 7" x 9" x 0.25";
 
**rod 1-1/8"(diam) x 1" (long);
 
**rod 2-1/8"(diam) x 10" (long);
 
**rod 4-1/2"(diam) x 10" (long);
 
**call Pocatello Partner Steel 233-2371;
 
**GOOGLE: BRASS SHEET -> '''Online Metals [http://www.onlinemetals.com/index.cfm]''', Metals Depot, Metal Mart, etc.;
 
 
 
*Assembly drawings need to be modified to reflect all recent updates (output Al plates, etc.);
 
 
=X-pinch driver fabrication to do list=
 
*Can we use cross instead of cube? '''(A: Cross - not, but reduced cross - yes)''';
 
*Do we need to use Cu gasket to seal CF flange? If so, we need a lot of them for every shot. '''(A: yes, we need to use Cu gaskets)''';
 
 
 
*Brick housing design and fabrication ('''done''');
 
 
*Isolating brick housing's sheets design and fabrication ('''done''');
 
 
*Output isolating plate design ('''done''');
 
*Output isolating plate fabrication ('''status: ordered Acrylic sheet''');
 
 
 
*X-pinch cathode/anode design and fabrication:
 
**Design x-pinch cathode/anode '''(in progress, drawings #2013.1.001.0010-0021 is finished and need to be approved by Spielman)''';
 
**Discuss possibilities of fabrication in IAC with Kevin ('''done''');
 
**Order brass cuts ('''done''');
 
**Fabricate anode/cathode/vacuum_chamber parts, drawings #2013.1.001.0010-0021;
 
 
 
*X-pinch vacuum chamber design and fabrication:
 
**Design x-pinch vacuum chamber, '''(done: drawings #2013.1.001.0021 (assembly)  and 2013.1.001.0030 (Lesker reassembled cross))''';
 
**Include Al plate's taped holes in drawing #2013.1.001.0008 '''(done)''';
 
**Discuss reassembling possibilities with Kevin '''(done)''';
 
**Buy all parts for x-pinch vacuum chamber:
 
***Buy LESKER 8"/2-3/4" reducing cross '''(done)''';
 
***Buy 8" flanges '''(done)''';
 
***locate at IAC 2-3/4 flange and viewport ('''done: asked Kevin and he told we have some''');
 
***Identify and buy gaskets/fasterners for cross;
 
*Fabricate vacuum chamber at IAC;
 
 
 
*O-Rings:
 
**Identify o-rings ('''done''');
 
**design o-ring groove '''(done)''';
 
**Include o-ring's grooves into the PMMA drawing #2013.1.001.0018 ('''done''');
 
**Buy o-rings;
 
**Fabricate grooves inside PMMA output plate, drawing #2013.1.001.0018
 
 
 
*Identify/buy charging lines;
 
*Locate vacuum pump;
 
*Locate RG-214 (2-3 m);
 
 
 
*Diagnostics: Rogowskii and B-Dot:
 
**Read Rick's notes and paper;
 
**design Rogovskii and B-dot;
 
**include in drawing ('''done for Rogowskii''');
 
**fabricate Rogovskii and B-dot;
 
 
 
*'''Parts have been ordered so far:'''
 
**brick housing sheets, flanges and covers, $910 [https://wiki.iac.isu.edu/index.php/File:E2GEN11090928.PDF];
 
**brick housing PMMA, $239 [https://wiki.iac.isu.edu/index.php/File:E2GEN11130949.PDF];
 
**Lesker reducing 4-way, 8" OD to 2-3/4 OD cross, $890 plus shipping [https://wiki.iac.isu.edu/index.php/File:Order_Report_from_The_Kurt_J.pdf], [http://www.lesker.com/newweb/flanges/fittings_cf_crosses.cfm?pgid=4wayreducer];
 
**8" (blank and 6" ID) flanges, $393 plus shipping [https://wiki.iac.isu.edu/index.php/File:MDC_Vacuum_011014.pdf];
 
**Plastic Material, HDPE and Acrylic, sheet and rod, $139.67 [https://wiki.iac.isu.edu/index.php/File:Professional_Plastics_Order_(59910).pdf];
 
**brass for anode/cathode, $463.37 (with shipping) [https://wiki.iac.isu.edu/index.php/File:Order_OnlineMetals.pdf];
 
*'''Total: $3035.04'''
 

Latest revision as of 22:40, 22 January 2014