Difference between revisions of "X-pinch driver 2-bricks fabrication"

From New IAC Wiki
Jump to navigation Jump to search
Line 58: Line 58:
 
[[File:Be transmission data1.jpg | 400 px]]  
 
[[File:Be transmission data1.jpg | 400 px]]  
  
If we will use 2-1/8 CF flanges CF flange windows, we will need Zero- Length Reducer Flanges (from 2 3/4 to 2 1/8) [http://www.lesker.com/newweb/flanges/flanges_cf_reducer.cfm?pgid=std]
+
For 2-1/8 CF flanges x-ray window, we will need Zero-Length Reducer Flange (from 2 3/4 to 2 1/8), like [http://www.lesker.com/newweb/flanges/flanges_cf_reducer.cfm?pgid=std]
  
  

Revision as of 23:49, 30 December 2013

go back


12/08/13

  • The updated drawing of bricks with remeasured front plate's holes created (drawing #2013.1.001.0001)


12/09/13

  • The list of possible manufacturing company for Brick's Housing (BH) parts production is established:
    • Partner Steel Co, Inc, Pocatello;
    • Valley Sheet Metal (VSM) Technologies, Idaho Falls;
    • Primear Technology, Blackfoot;
    • Northwest wire EDM, Spokane, WA;
    • Nelson Metal Technology, Payette, ID;
    • Water Jet Cutting, Albuquerque;
  • All above companies have been contacted for quotes. Criteria were price and speed of production.


12/10/13

  • Brick's Housing (BH) parts (steel/AL/PMMA sheets) drawings is approved by Spielman (drawings #2013.1.001.0002-0009)


12/11/13

  • VSM Technologies: selected as manufactured company for BH parts (drawings #2013.1.001.0002-0009)


12/17/19

  • BH parts arrived at IAC and inspected. Kevin is going to assemble and weld them all together.


12/18/19

  • Cathode/anode drawings submitted to Spielman for approving (drawings #2013.1.001.0010-0017)
  • PMMA_Output_Sheet/Charging_Isolating_Tube drawings submitted to Spielman for approving (drawings #2013.1.001.0018-0019)
  • X-pinch driver assembly drawing with included cathode/anode submitted to Spielman for approving (drawing #2013.1.001.0020)
  • PARKER's Viton O-rings V0769-60 2-246 (2 pcs), ID 4 1/2 and W 1/8", selected for vacuum seal inside the cathode/anode section.


12/19/13

  • LESKER reduced 4-way cross (C-0800-275, $890) found as a candidate for vacuum chamber
  • LESKER reduced 4-way cross drawing downloaded and incorporated into SolidWorks (assembly file Lesker_C-800_275\C-0800-275_reassembled)
  • LESKER reduced 4-way cross redesigned to match our x-pinch driver (drawing file Lesker_C-800_275\LESKER_C-0800-275_REASSEMBLED)


12/20/13

  • Some changes to parts have been done to accommodate LESKER redesigned cross:
    • 1) for Al output plate, the inner cut increased from 4.5 diameter to 10" diameter to match the cross (drawing #2013.1.001.0008);
    • 2) for anode can, the slot size increased from 0.4" to 0.5" to march x-pinch wires length (drawing #2013.1.001.0014);
  • Reassembled LESCER cross drawing submitted to Spielman for approving (drawing LESKER C-0800-275_REASSEMBLED)
  • X-pinch driver assembly drawing with included cathode/anode/cross submitted to Spielman for approving (drawing #2013.1.001.0021)
  • LESCER cross and new assembly drawings is approved by Spielman:


12/30/13

  • LESKER reduced 4-way cross (C-0800-275, $890) is ordered. Expected delivery id January 16, 2014. Comments: this one we will cut and reassemble later in the way we need. Just to remind, I plan two use one 8" flange for plate connection, one 8" flange for x-pinch access and vacuum pump connection, one 2 3/4 flange for x-ray diagnostics and one 2 3/4 flange for x-ray output.


  • for x-ray windows we can use Beryllium window (available from Moxtek in 1-1/3 and 2-1/8 CF flanges [1]).

Be transmission data1.jpg

For 2-1/8 CF flanges x-ray window, we will need Zero-Length Reducer Flange (from 2 3/4 to 2 1/8), like [2]


Other parts we need for vacuum chamber are:

  • flanges:
    • 8" fixed blank CF flange, part #F0800X000N, $125;
    • 2 3/4" fixed bore 1.63" CF flange, part #F0275X175N, $15;
    • 2 3/4" CF flange with x-ray windows, part # identify;
  • gaskets:
    • 1/4 Hard OFHC Copper Gasket for 2-3/4" CF flange, part #GA-0275, set of 10, $26.40;
    • 1/4 Hard OFHC Copper Gasket for 8" CF flange, part #GA-0800, set of 10, $75.00.
  • fasteners:
    • 5/16—24 x 2-1/4" Bolt & Nut Set, part #HBS31224225, set of 25, $37.58;
    • 5/16—24 x 1-3/4" Bolt Kits, part #HBK31224175, set of 25, $30.60; (need 1" length)
    • 1/4—28 x 1-3/8" Bolt & Nut Set, part #HBS25028138, set of 25, $29.38;
  • Total quote is xxx.xx plus shipping.



To Do List:

  • Can we use cross instead of cube? (A: Cross - not, but reduced cross - yes)
  • Do we need to use Cu gasket to seal CF flange? If so, we need a lot of them for every shot.(A: yes, we need to use Cu gaskets);
  • Identify/buy all needed flanges/gaskets for the cross; (done)
  • o-ring in PMMA ~3 mm. Locate position and include in drawing. (done)
  • Buy LESKER reducing cross, RACL60 (done, Dec 30, 2013, expected delivery Jan 16, 2014);
  • Buy flanges/gaskets;
  • Buy all fasteners;
  • Include all taped holes in drawing;
  • Include groove for two o-rings into the isolating output PMMA drawing, #2013.1.001.0018
  • Fabricate anode/cathode/vacuum_chamber parts (drawings #2013.1.001.0010-0021)
  • Locate vacuum pump
  • Diagnostics: Rogowskii and B-Dot, design and include in drawing