Difference between revisions of "TF NEUP 2011"

From New IAC Wiki
Jump to navigation Jump to search
Line 1: Line 1:
 
Technical Work Scope Identifier: FC-5
 
Technical Work Scope Identifier: FC-5
 +
 +
 +
From the RFP
 +
 +
 +
'''Mission Supporting R&D''' is considered creative, innovative, and transformative (blue-sky), but
 +
must also support the NE mission.  Mission-supporting activities that could produce breakthroughs
 +
in nuclear technology are also invited to this solicitation.  This includes research in the fields or
 +
disciplines of nuclear science and engineering that are relevant to NE’s mission though may not
 +
fully align with the specific initiatives and programs identified in this solicitation.  This includes,
 +
but is not limited to, Nuclear Engineering, Nuclear Physics, Health Physics, Radiochemistry,
 +
Nuclear Materials Science, or Nuclear Chemistry.  Examples of topics of interest are new reactor
 +
designs and technologies, advanced nuclear fuels and resource utilization, instrumentation and
 +
control/human factors, radiochemistry, fundamental nuclear science, and quantification of
 +
proliferation risk and creative solutions for the management of used nuclear fuel.
 +
Program supporting research requested by this solicitation is detailed as discreet workscopes in
 +
Appendix A.  The information is organized by program area with each specified workscope
 +
providing the basis for a stand-alone R&D pre-application submittal. 
 +
 +
 +
'''Fuel Cycle Research and Development'''
 +
New and improved detector systems and sensor materials that can be used to increase the
 +
accuracy, reliability, and efficiency of nuclear materials quantification and tracking from the
 +
perspective of the operator or state-level regulator.  Such systems could include new neutron
 +
coincidence/anti-coincidence counting, spectroscopic analysis, chemical, calorimetric, or other
 +
non-nuclear methods, as well as any other novel methods with potential MC&A benefits;
 +
  
 
=Project Summary=
 
=Project Summary=

Revision as of 21:38, 17 October 2011

Technical Work Scope Identifier: FC-5


From the RFP


Mission Supporting R&D is considered creative, innovative, and transformative (blue-sky), but must also support the NE mission. Mission-supporting activities that could produce breakthroughs in nuclear technology are also invited to this solicitation. This includes research in the fields or disciplines of nuclear science and engineering that are relevant to NE’s mission though may not fully align with the specific initiatives and programs identified in this solicitation. This includes, but is not limited to, Nuclear Engineering, Nuclear Physics, Health Physics, Radiochemistry, Nuclear Materials Science, or Nuclear Chemistry. Examples of topics of interest are new reactor designs and technologies, advanced nuclear fuels and resource utilization, instrumentation and control/human factors, radiochemistry, fundamental nuclear science, and quantification of proliferation risk and creative solutions for the management of used nuclear fuel. Program supporting research requested by this solicitation is detailed as discreet workscopes in Appendix A. The information is organized by program area with each specified workscope providing the basis for a stand-alone R&D pre-application submittal.


Fuel Cycle Research and Development New and improved detector systems and sensor materials that can be used to increase the accuracy, reliability, and efficiency of nuclear materials quantification and tracking from the perspective of the operator or state-level regulator. Such systems could include new neutron coincidence/anti-coincidence counting, spectroscopic analysis, chemical, calorimetric, or other non-nuclear methods, as well as any other novel methods with potential MC&A benefits;


Project Summary

We propose to develop a gaseous detector sensitive to fast (100 keV - 100 MeV) neutrons to monitor the neutron flux in nuclear reactors. The monitoring of a reactor core's neutron flux has been a long standing problem due to the high neutron and gamma intensity. Gaseous detector technology from recent developments in high energy physics will be used to improve a fission chambers ability to operate in a high neutron flux environment. The technology in question will decrease an ionization chambers response time by at least a factor of 3. The faster detector signal will result in less dead time and increase the neutron flux rate that will cause detector signal pile up.

HRRL 7-31-09 MetalicaPlastika Start 1.png

Importance and relevance of proposed work

Logical pathway to work accomplishments

Deliverables and outcomes

Timeline

Budget

Neutron fluxes in reactors

according to http://www.bnl.gov/bnlweb/history/HFBR_main.asp

a 40 MW reactor at Brookhaven's High Flux Beam Reactor (HBFR) produced a neutron flux of [math]1.5 \times 10^{15} \frac{n /cm^2}{s}[/math] for experiments. The neutron flux was a maximum outside the core because the neutrons were directed tangentially to the core instead of radially.

1e11 to 1e12 neutrons per cm^2 per second may be more typical

Let's assume this flux is an upper limit for a detector to measure neutron fluxes in a reactor core. The pulse width of a regular GEM detector is [math]50 \times 10^{-9}[/math] sec. Because of the high gain a signal may be observed over a surface area of 3 cm^2 (10 cm by 300 \times 10^{-3} cm ). A GEM detector with this active area would only be able to count neutron fluxes of [math]1 \times 10^{7} \frac{n /cm^2}{s}[/math] if the detector efficiency was 100 %. A detector efficiency of 10^{-5} would be able to see rates of 10^{11}.


The pulse width of a standard ionization chamber is on the order of 300 nsec, so a standard GEm detector would only be able to have a factor of 6 higher rate than a typical ionization/fission chamber.

Path to work accomplishments

The first year of effort will focus on the production of pre-amplifiers for ionization chamber. A fissionable material will be added to the ionization chamber in year two followed measurements of the chamber's neutron detection efficiency.

Deliverables and outcomes

1.) Neutron sensitive ionization chamber (no position readout)


Time Frame

Budget

IAC Task

Each year

1 grad students ($50k)

2 faculty summer months ($20k)

Beam time: electron experiment which produces isotropic neutrons. Compare neutron rates seen by several know detectors to the rate from the THGEM based detector.

Bibliography

  1. File:NEUP Pre-app RFP.pdf
  2. "Fission chambers for CANDU SDS neutronic trip applications", V. Mohindrs, M. Vartolomei, and A. McDonald, 28th Annual Canadian Nuclear Society (CNS) conference, June 3-6, 2007New Brunswick, Canada Media:Virender_CANDU2007.pdf
  3. GE builds nuclear reactor instruementation http://www.ge-mcs.com/en/nuclear-reactor-instrumentation/

Forest_Proposals