Difference between revisions of "Signal cable timing"

From New IAC Wiki
Jump to navigation Jump to search
Line 4: Line 4:
 
PMT timing relative to D30T001 is measured by splitting a pulse from a pulse generator.
 
PMT timing relative to D30T001 is measured by splitting a pulse from a pulse generator.
  
PMT top-bottom difference is the mean time difference taken from the TDC data of a coincidence measurement with the CF-252 source. The source was placed in the center of all detectors and 150.5 cm above the floor.  The trigger detector was located 5.5 cm below the very bottom of the source.
+
PMT top-bottom difference is the mean time difference of the PMT's, where the data is taken from the TDC spectrum of a coincidence run with the CF-252 source. The source was placed in the center of all detectors and 150.5 cm above the floor.  The trigger detector was located 5.5 cm below the very bottom of the source.
  
 
{| border="1" style="border: 4px solid black; border-collapse: collapse; padding: 5px; text-align: center "
 
{| border="1" style="border: 4px solid black; border-collapse: collapse; padding: 5px; text-align: center "

Revision as of 21:41, 17 August 2016

Go back


PMT timing relative to D30T001 is measured by splitting a pulse from a pulse generator.

PMT top-bottom difference is the mean time difference of the PMT's, where the data is taken from the TDC spectrum of a coincidence run with the CF-252 source. The source was placed in the center of all detectors and 150.5 cm above the floor. The trigger detector was located 5.5 cm below the very bottom of the source.

Detector PMT sig. cable [math]\Delta t[/math] relative to D30T001 [ns] PMT bot - PMT top [ns]
angle color
30 Red Top D30T001 +0 (by definition) +15
Bot D30B002 +15
90 Yellow Top D90T003 +1 +10
Bot D90B004 +11
150 Blue Top D150T005 +1 +13
Bot D150B006 +14
225 Wood Top D225T007 -3 +23
Bot D225B008 +20

Trigger plugged into patch panel 223A15 : -8 ns