Difference between revisions of "September 9, 2011"

From New IAC Wiki
Jump to navigation Jump to search
Line 56: Line 56:
 
threshold @A22 lowered to -100 mV
 
threshold @A22 lowered to -100 mV
 
|-
 
|-
|2354||Up 2 mm||In ||Open ||Up 2 mm||DU plate ||align="left"|Production run.<br>
+
|2354||Up 2 mm||In ||Open ||Up 2 mm||DU plate  
R(upstream) = 4228/188008 = 0.022 e+/pulse  
+
|align="left"|R(upstream) = 4228/188008 = 0.022 e+/pulse,<br>R(upstream) = 5169/188008 = 0.027 e+/pulse  
R(upstream) = 5169/188008 = 0.027 e+/pulse  
+
Production run.
 
|-
 
|-
|2355||Up 2 mm||In ||Open ||Out ||DU plate ||align="left"|background check<br>
+
|2355||Up 2 mm||In ||Open ||Out ||DU plate  
threshold @A20 lowered to -100 mV<br>
+
|align="left"|R(upstream) = 766/44747 = 0.017 e+/pulse,<br>R(upstream) = 962/44747 = 0.021 e+/pulse
R(upstream) = 766/44747 = 0.017 e+/pulse  
+
background check<br>
R(upstream) = 962/44747 = 0.021 e+/pulse  
+
threshold @A20 lowered to -100 mV
 
|-
 
|-
 
|}
 
|}

Revision as of 21:13, 9 September 2011

go back

summary what was been done

Run # Beam Dump magnet Collimator Radiator 10 um Al Target Comments
2339 Up 2 mm In Open Up 2 mm No R(upstream) = 2648/35092 = 0.075 e+/pulse,
R(downstream) = 3191/35092 = 0.091 e+/pulse
2341 Up 2 mm In Open Out No R(upstream) = 1088/35494 = 0.031 e+/pulse,
R(downstream) = 1328/35494 = 0.037 e+/pulse.

About 59% of photons are coming from the radiator. Bad

2342 Down 2 mm In Open Out No R(upstream) = 1586/36678 = 0.043 e+/pulse,
R(downstream) = 1888/36678 = 0.051 e+/pulse.
2343 Down 2 mm In Open Down 2 mm No R(upstream) = 2232/35488 = 0.063 e+/pulse.

About 32% of photons are coming from the radiator. Bad

2344 Centered In Open Centered No R(upstream) = 2683/35095 = 0.076 e+/pulse.
2345 Centered In Open Out No R(upstream) = 1039/35094 = 0.029 e+/pulse.

About 62% of photons are coming from the radiator. Bad

2346 Centered In Open Out No R(upstream) = 1286/35885 = 0.036 e+/pulse.

Improved shielding around dump.

Based on the previous results the beam is total crap, so beam tuned up.
2349 Centered In Open Out No R(upstream) = 404/35489 = 0.011 e+/pulse.
2350 Centered In Open Out No R(upstream) = 428/35093 = 0.012 e+/pulse.

Additional shielding around the vacuum window of the beam pipe.

2351 Centered In Open Centered No R(upstream) = 1314/35094 = 0.037 e+/pulse.

About 68% of photons are coming from the radiator. Still bad. Additional shielding around the vacuum window of the beam pipe is removed.

2352 Up 2 mm In Open Up 2 mm D2O bottle Production run.
2353 Up 2 mm In Open Out D2O bottle background check

threshold @A22 lowered to -100 mV

2354 Up 2 mm In Open Up 2 mm DU plate R(upstream) = 4228/188008 = 0.022 e+/pulse,
R(upstream) = 5169/188008 = 0.027 e+/pulse

Production run.

2355 Up 2 mm In Open Out DU plate R(upstream) = 766/44747 = 0.017 e+/pulse,
R(upstream) = 962/44747 = 0.021 e+/pulse

background check
threshold @A20 lowered to -100 mV

Beam Realignment

Screen shot using Phosphorous screen

9 9 11 10am.jpg

Electron beam on glass

E-glass.jpg

12pm upstream view screen

12pm upstream.jpg

12pm downstream view screen

12pm downstream.jpg