Beam Parameters:

  • current 140 mA
  • pulse width 2 us
  • rep rate 180 Hz
  • E = 25 MeV


Initial Test for Verification

Run # Beam Dump magnet Collimator add coll Hardener 1" Al Radiator 25 um Al Target Comments
2515 Up
90A
In Open In Yes In DU cylinder Test radiator in/out.

144632 pulses
R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2516 Up
90A
In Open In Yes Out DU cylinder Test radiator in/out.

0 pulses
R(bottom) = 0 n/pulse
R(upstream) = 0 e+/pulse
About 0% of photons are coming from the radiator according to PS.

2517 Down
86A
In Open In Yes In DU cylinder Test radiator in/out.

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2518 Down
86A
In Open In Yes Out DU cylinder Test radiator in/out.

0 pulses
R(bottom) = 0 n/pulse
R(upstream) = 0 e+/pulse
About 0% of photons are coming from the radiator according to PS.

Production runs

Run # Beam Dump magnet Collimator add coll Hardener 1" Al Radiator 25 um Al Target Comments
2519 Up
90A
In Open In Yes In DU cylinder Long production run: 0 pulses (90 minute run)

Operator said the beam is really jittery
R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2520 Down
86A
In Open In Yes In DU cylinder Long production run: 0 pulses (90 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2521 Down
86A
In Open In Yes Out DU cylinder Long production run: 0 pulses (30 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2522 Up
90A
In Open In Yes In DU cylinder Long production run: 0 pulses (20 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2523 Up
90A
In Open In Yes In DU cylinder Long production run: 0 pulses (70 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2524 Down
86A
In Open In Yes In DU cylinder Long production run: 0 pulses (90 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2525 Down
86A
In Open In Yes Out DU cylinder Long production run: 0 pulses (20 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse

2513 Down
86A
In Open In Yes In None Long production run: 0 pulses (30 minute run)

R(bottom) = 0 n/pulse -> × 180 Hz × 60 sec/min = 0 n/min
R(upstream) = 0 e+/pulse