Difference between revisions of "Ribbon Cable Attenuation Measurements"

From New IAC Wiki
Jump to navigation Jump to search
Line 16: Line 16:
 
|-
 
|-
 
|<math>30\ ns</math> ||<math>4.0\ V</math> ||<math>1.8\ V</math> ||55 % ||see pictures about pulse's shape change
 
|<math>30\ ns</math> ||<math>4.0\ V</math> ||<math>1.8\ V</math> ||55 % ||see pictures about pulse's shape change
 
+
|-
  
 
{| border="3"  cellpadding="20" cellspacing="0"
 
{| border="3"  cellpadding="20" cellspacing="0"
 
| ||  
 
| ||  
 
|-
 
|-

Revision as of 22:32, 18 January 2011

Experimental Set Up

Measurements

Pulse width [math]V_1[/math] [math]V_2[/math] Attenuation, % Comments
[math]100\ \mu s[/math] [math]5.0\ V[/math] [math]4.5\ V[/math] 10 %
[math]10\ \mu s[/math] [math]5.0\ V[/math] [math]4.2\ V[/math] 16 %
[math]1\ \mu s[/math] [math]5.0\ V[/math] [math]3.0\ V[/math] 40 % see pictures about pulse's shape change
[math]100\ ns[/math] [math]5.0\ V[/math] [math]2.8\ V[/math] 44 % see pictures about pulse's shape change
[math]30\ ns[/math] [math]4.0\ V[/math] [math]1.8\ V[/math] 55 % see pictures about pulse's shape change