Difference between revisions of "R3"

From New IAC Wiki
Jump to navigation Jump to search
 
(27 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
A description of the Region 3 (RIII) Design for CLAS12
 
A description of the Region 3 (RIII) Design for CLAS12
 +
 +
=Press Releases=
 +
 +
Last Story was on September 23, 2013 in the ISJ "High Tech Project: ISU building chambers for Jefferson Lab detector upgrade" by jimmy handcock
 +
 +
http://idahostatejournal.com/members/high-tech-project-isu-building-chambers-for-jefferson-lab-detector/article_2e10e73e-26e5-11e3-9d2b-0019bb2963f4.html
 +
 +
Text for new Story
 +
 +
taylandy@isu.edu
 +
 +
It has been fours years since Idaho State University was awarded a half million dollar grant to build a set of precision devices called drift chambers.  The devices built by ISU were commissioned last week and are now ready be used for the next decade by scientists from around the world.
 +
 +
Supported an ISU clean room
 +
 +
trained locals as technicians who have gone on to ON semiconductor.
 +
 +
Exposed ISU students to these devices.
 +
 +
= [[progress reports]] =
 +
 +
=presentation=
 +
 +
[[Media:29.Oct.08]]
 +
 +
= Timeline=
 +
{| border="1"  |cellpadding="20" cellspacing="0
 +
|-
 +
|Description || Start Date || End Date || New End Date
 +
|-
 +
| PDR: Preliminary Design Review: 3-D models || 5/28/07 || 9/24/07 || 3/31/08
 +
|-
 +
| [[DDP:Detailed Design Phase: Drawing and Assembly Package]] || 10/8/07 || 3/10/08 || 5/12/08
 +
|-
 +
| [[PFD:Production_of_Fabrication_Drawings]] || 4/14/08|| 9/22/08 || 9/22/08
 +
|}
 +
 
=Conceptual Design=
 
=Conceptual Design=
  
Line 8: Line 45:
 
   
 
   
 
A view of the 6 piece assembly can be viewed as  
 
A view of the 6 piece assembly can be viewed as  
[[Image:Basic_Concept_two.jpg]]
+
[[Image:R3AllSectors.jpg]]
  
  
Line 21: Line 58:
 
A Sample assembly of the slice can be Viewed as
 
A Sample assembly of the slice can be Viewed as
  
[[Image:Basic_Concept_Three.jpg]]
+
[[Image:basic_Concept_Three.jpg]]
  
  
Line 36: Line 73:
  
  
'''Face plate:'''  
+
'''Back plate:'''  
  
Face plate is the top plate which holds the end plate together on the top side.
+
Back plate is the top plate which holds the end plate together on the top side.
  
 
=Design criteria=
 
=Design criteria=
Line 71: Line 108:
 
[[Image:end_plate_dimensions.jpg | 500 px]]
 
[[Image:end_plate_dimensions.jpg | 500 px]]
  
==Face Plate==
+
==Back Plate==
 +
 
 
==Nose Plate==
 
==Nose Plate==
  
Line 96: Line 134:
 
## Density =
 
## Density =
  
==== Backplate Material====
+
==== Downstream window Material====
 
#Hexcell Honeycomb foam HRH 10-1/8 -1.8
 
#Hexcell Honeycomb foam HRH 10-1/8 -1.8
 
##0.010 (Skin 1) + 1.520 (Core) + 0.010 (Skin 2) inches in thickness
 
##0.010 (Skin 1) + 1.520 (Core) + 0.010 (Skin 2) inches in thickness
Line 144: Line 182:
 
===Refined 3-D Model with Mylar sheet===
 
===Refined 3-D Model with Mylar sheet===
  
Gas pressure inside the chamber will be just above 1 atm in order to have a constant flow of ArCo2.  The average differential pressure is expected to be about 1/8 of an inch of water (<math>3 \times 10^{-4} Atm , 4.5 \times 10^{-3} lbs/in^2</math>). The peak pressure differential is assumed to be 5 times higher.
+
Gas pressure inside the chamber will be just above 1 atm in order to have a constant flow of ArCo2.  The average differential pressure is expected to be about 0.04 of an inch of water (<math>Atm , lbs/in^2</math>). The peak pressure differential is assumed to be 5 times higher.
  
 
=Presentation=
 
=Presentation=
Line 156: Line 194:
  
 
= References=
 
= References=
 
+
#[http://clasweb.jlab.org/wiki/index.php/12GeV_DC_Meeting_Minutes_and_Notes JLab's CLAS12 DC Meeting wiki]
 
#[http://www.jlab.org/Hall-B/secure/clas12/RIII/ISU_Design/Progress.html R3 status page at JLAB]
 
#[http://www.jlab.org/Hall-B/secure/clas12/RIII/ISU_Design/Progress.html R3 status page at JLAB]
 
# CLAS detector NIM article  [[Media:NIM_A449.pdf]]
 
# CLAS detector NIM article  [[Media:NIM_A449.pdf]]
Line 185: Line 223:
 
=Reports=
 
=Reports=
 
==Draft for the base End plate Deflection analysis==
 
==Draft for the base End plate Deflection analysis==
[[media:Draft_1_end_plate_deflection_analysis.pdf]]
+
[[image:Draft_1_end_plate_deflection_analysis.pdf]]
 +
==2-08 Report==
 +
[[R3DC_Report_2-08]]
 +
 
 +
 
 +
 
 +
[http://www.iac.isu.edu/mediawiki/index.php/Hall_B Go Back]

Latest revision as of 23:03, 8 February 2017

A description of the Region 3 (RIII) Design for CLAS12

Press Releases

Last Story was on September 23, 2013 in the ISJ "High Tech Project: ISU building chambers for Jefferson Lab detector upgrade" by jimmy handcock

http://idahostatejournal.com/members/high-tech-project-isu-building-chambers-for-jefferson-lab-detector/article_2e10e73e-26e5-11e3-9d2b-0019bb2963f4.html

Text for new Story

taylandy@isu.edu

It has been fours years since Idaho State University was awarded a half million dollar grant to build a set of precision devices called drift chambers. The devices built by ISU were commissioned last week and are now ready be used for the next decade by scientists from around the world.

Supported an ISU clean room

trained locals as technicians who have gone on to ON semiconductor.

Exposed ISU students to these devices.

progress reports

presentation

Media:29.Oct.08

Timeline

Description Start Date End Date New End Date
PDR: Preliminary Design Review: 3-D models 5/28/07 9/24/07 3/31/08
DDP:Detailed Design Phase: Drawing and Assembly Package 10/8/07 3/10/08 5/12/08
PFD:Production_of_Fabrication_Drawings 4/14/08 9/22/08 9/22/08

Conceptual Design

The location of Region III on this drift chamber can be viewed as
Basic Concept one.jpg

Region III is assembled with 6 Eqi-shaped pieces. Each of these pieces resembles a Pizza slice which together forms the whole chamber.

A view of the 6 piece assembly can be viewed as R3AllSectors.jpg


Each of these pieces is made of 3 kinds of plates.

1. Nose Plate (1 No.)

2. End Plate (2 No’s)

3. Face Plate (1 No.)

A Sample assembly of the slice can be Viewed as

Basic Concept Three.jpg


End Plate:

There are 2 end plates for each slice which are attached opposite to each other. There are several holes on each end plate through which sets of wires are passed and connected to both end plates of a particular slice. The whole area in which holes are drilled on each End plate can be further divided into 2 areas; upward wire area and Downward wire area. A wire from upward wire area of end plate ‘A’ is drawn to the downward wire area in the opposite end plate ‘B’ and vice versa. Both these wires are angled at 6 degrees to the imaginary midline, which passes through the Nose plate and the Face Plate of each slice. End plate can be Viewed as

End Plate View.jpg

Nose Plate:

This is the place which forms the base for each slice. Both the end plates are attached at the opposite ends of the Nose plate. The angled end of the end plates are attached to this nose plate, so that the end plates are projected at an angle in 3-D.


Back plate:

Back plate is the top plate which holds the end plate together on the top side.

Design criteria

The Design Criteria is to develop all the necessary dimensions from the known dimensions.

The known dimensions are


• Distance from target to first sense wire plane along a ray which is normal to the end plate = 4746.5 mm

• Chamber Tilt Angle = 25 Degrees

• Maximum Scattering Angle = 45 Degrees

• Minimum Electron Scattering angle = 5 Degrees

• Distance between the two Adjacent Pieces = 160 mm


The Definition of these given Dimensions can be viewed in the following pictures

Definition Of Terms One.jpg Definition Of Terms Two.jpg


Theses known dimensions are used in the determination of the remaining dimensions of the chamber.

Dimensions

End Plate

Dimensions of the End Plate can be Viewed Below
End plate dimensions.jpg

Back Plate

Nose Plate

Preliminary Design Phase (9/24/07)

Design

The endplate is a composite material composed of an inner polyerethane foam core with steel sheets glued to the largest area sides. The endplate, while made entirely of this composite, has a large number of holes in two central region through which the drift chamber wires are supported. To account for the effects of these holes the composite is defined in terms of two materials. Material 1 represents the composite material without holes while Material 2 has a density to reflect the presence of drilled holes.

The long sides of the endplate composite material have two support structures. On one side, carbon fiber rods (Material 3) are placed to help reduce reflections. On the other side a Hexcell foam impregnated with carbon fiber (Material 4) is used as a backing when all four sides of the drift chamber are assembled.

Material and cross section of drift chamber frames, endplates, back plates, and nose plates

Endplate material

  1. Polyeurethane Foam
    1. R3 Design specification: General Plastics Mfg. Co., "LAST-A-FOAM", FR-3700
    2. Youngs modulus: 140 MPa
    3. Density 240 kg/[math]m^3[/math]
  2. Stanless steel plates
    1. 0.048 inch thick plates on both sides of Foam
    2. Youngs Modulus=
    3. Density =

Downstream window Material

  1. Hexcell Honeycomb foam HRH 10-1/8 -1.8
    1. 0.010 (Skin 1) + 1.520 (Core) + 0.010 (Skin 2) inches in thickness
    2. impregnated wih graphite fabric
    3. HRH-10 is the material name
    4. 1/8 represents the cell size (diameter between opposing flat section)
    5. Density= 1.8 lb/[math]ft^3[/math]
    6. Young's Modulus=

Wire hole patterns and feedthrough details

With a total of 112 sense wires and 44 wire layers, we exect to drill 4,928 precision holes in the drift chamber endplate.

A Basic View of the Hole on the End Plate with the Feedthrough can be Shown Below

Hole And Feed Through.jpg

Method for attaching/securing wires

Support bracings, if needed

Lifting attachments and supports

Assembly fixture

Mechanical Analysis

ANSYS Model

Ansys is used as the modeling and analysis tool. Several cases both in 2-D and 3-D models will be analyzed.

In this explanation. 2-D model is itself is a 3-D model. However, the deflection of a single end plate will be analyzed with some assumptions

2-D Model

This 2-D model is basically a 3-D model of the end plate itself. Several orientations have been analyzed. The description of this 2-D model can be observed below. 2-D.jpg 2-D materials.jpg

2-D model results of several orientations and cases are tabulated below

2-D results.jpg

3-D Model

This 3-D model is a one (out of six) 3-D piece model.
3-Dim.jpg 3d-loads.jpg Results 3d.jpg

Refined 3-D Model with Mylar sheet

Gas pressure inside the chamber will be just above 1 atm in order to have a constant flow of ArCo2. The average differential pressure is expected to be about 0.04 of an inch of water ([math]Atm , lbs/in^2[/math]). The peak pressure differential is assumed to be 5 times higher.

Presentation

Drawings

Vendors

  1. Hysol 9339 glue File:Hysol9339glue.pdf is used for the endplates to glue the 0.048 inch thick Stanless steel plates to the Polyeurethane "LAST-A-FOAM", FR-3700 Foam. Vendor used for previous CLAS chambers: Dexter Corp., Adhesives & Structural Materials Division, 465 Marietta, GA 30064, PH. 404-427-1567
  2. Epon is the glue used for the feedthroughs, potting pins, and to seal connections. The previous CLAS drift chambers used the Epon 828 resin with Versamid 140 hardener in a ratio of 100:44.5. Other types may have more plasticisers that can out-gas. Our source for Epon was E.V. Roberts and Associates, Inc., 8500 Steller Drive, PO Box 868, Culver City, CA 90232, PH. 213-870-9561.

Provide materials

Perform fabrication

References

  1. JLab's CLAS12 DC Meeting wiki
  2. R3 status page at JLAB
  3. CLAS detector NIM article Media:NIM_A449.pdf
  4. Mac's CLAS 12 tracking design writeup May 15 , 2005 Media:CLAS12-5-2005.pdf
  5. Mac's CLAS 12 tracking design writeup Jan. 1, 2007 Media:CLAS12-1-2007.pdf

JLAB visit

9/17/09

Task list

  1. review construction of R1 prototype chamber
  2. compare Material descriptions
  3. retrive Hexcell sample of R3 outer Shell
  4. Review ISU's current ANSYS model with bob williams
  1. Search for any R3 endplate remnants from current CLAS
  2. Make sure we have necessary connector for Baby chamber preamp output to out amplifiers
  3. can we borrow a VME ADC
  1. Check parameters of polyurethane foam listed above with vendors
  2. get Young's modulus for outer shell
  3. first deflection picture of endplate with/without carbon fiber rods

Presentation

Dec, 11, 2007

Reports

Draft for the base End plate Deflection analysis

File:Draft 1 end plate deflection analysis.pdf

2-08 Report

R3DC_Report_2-08


Go Back