R1S6 SL2 HVB6 BurnIn

From New IAC Wiki
Revision as of 00:34, 6 March 2013 by Conedavi (talk | contribs)
Jump to navigation Jump to search
Date Time (24h) HV Board ID Guard (V) Field (V) Sense (V) Sense ([math]\mu[/math]A) Field ([math]\mu[/math]A) comments
03/05/13 16:36 S6 SL2 HVB6 50 -50 50 0.000 0.015 Probed traces and pins connected to boots for fields/guard, all are showing voltage.
03/05/13 16:47 S6 SL2 HVB6 536 -500 500 0.000 0.015
03/05/13 16:51 S6 SL2 HVB6 536 -700 1100 0.000 0.015 Field current peaked around 0.085 while voltage was rising. Sense current peaked around 0.005 while voltage was rising.
03/05/13 16:52 S6 SL2 HVB6 536 -700 1100 0.025 0.102
03/05/13 16:54 S6 SL2 HVB6 536 -750 1100 0.030 0.120
03/05/13 16:57 S6 SL2 HVB6 536 -750 1200 0.120 0.210
03/05/13 16:58 S6 SL2 HVB6 536 -750 1300 0.290 0.370
03/05/13 16:59 S6 SL2 HVB6 536 -750 1400 0.68 0.77
03/05/13 17:01 S6 SL2 HVB6 536 -750 1500 1.3 1.4
03/05/13 17:09 S6 SL2 HVB6 536 -750 1500 1.15 1.25
03/05/13 17:29 S6 SL2 HVB6 536 -750 1500 1.06 1.15