R1S6 SL2 HVB2 BurnIn

From New IAC Wiki
Revision as of 19:33, 28 February 2013 by Foretony (talk | contribs) (Created page with " {|border="1" | cellpadding="5" cellspacing="0 class="wikitable" |- | colspan="5" align="center" | '''Sector 6 - Serial Numbers on STB & HVB''' |- | || colspan="2" align="cente…")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Sector 6 - Serial Numbers on STB & HVB
Top Endplate Bottom Endplate
Board # (nose=1, tail=7) SL1 (STB) SL2 (HVB) SL1 (HVB) SL2 (STB)
1 G1202270 ? ? K1202516
2 G1202266 ? ? J1202341
3 G1202273 ? ? J1202339
4 G1202275 ? ? K1201716
5 G1202271 ? ? K1201717
6 G1202274 ? ? K1201719
7 G1202272 ? ? K1202346
HV Burn-in Log
Date Time (24h) HV Board ID Guard (V) Field (V) Sense (V) Sense ([math]\mu[/math]A) Field ([math]\mu[/math]A) comments
02/23/13 14:00 S6 SL2 HVB1 525 -700 700 2.2
02/23/13 14:20 S6 SL2 HVB1 525 -700 1400 8.3
02/23/13 14:24 S6 SL2 HVB1 525 -700 1400 5.145
02/23/13 14:27 S6 SL2 HVB1 500 -500 500
02/23/13 14:28 S6 SL2 HVB1 500 ? 700 0
02/23/13 14:41 S6 SL2 HVB1 525 -525 525
02/23/13 14:41 S6 SL2 HVB1 525 -700 700
02/23/13 14:49 S6 SL2 HVB1 525 -700 1400 .5 .7
02/23/13 15:50 S6 SL2 HVB1 525 -700 1450 .8 .775
02/23/13 15:52 S6 SL2 HVB1 525 -700 1400 .465 .465
02/23/13 17:25 S6 SL2 HVB1 536 -700 1500 .720
02/25/13 17:05 S6 SL2 HVB7 536 -500 550 .08 .075
02/25/13 17:15 S6 SL2 HVB7 536 -700 700 .08 .01
02/25/13 17:18 S6 SL2 HVB7 536 -700 1000 .12 .05
02/25/13 17:21 S6 SL2 HVB7 536 -700 1000 .345
02/25/13 17:24 S6 SL2 HVB7 536 -700 1200 8.9 almost tripped
02/25/13 17:26 S6 SL2 HVB7 536 -700 1100 1.85
02/25/13 17:31 S6 SL2 HVB7 536 -700 1200 8.6 Almost lowered voltage but it's decreasing
02/25/13 17:34 S6 SL2 HVB7 536 -700 1200 7.3
02/25/13 17:38 S6 SL2 HVB7 536 -700 1200
tripped
02/25/13 17:38 S6 SL2 HVB7 536 -700 1150 2.85
02/25/13 17:55 S6 SL2 HVB7 536 -700 1150 1.04 Powered down at end of day (18:00)
02/26/13 14:25 S6 SL2 HVB7 536 -500 500 0 0.01
02/26/13 14:30 S6 SL2 HVB7 536 -700 700 0 0.035
02/26/13 14:33 S6 SL2 HVB7 536 -700 1000 0.3 0.38
02/26/13 14:33 S6 SL2 HVB7 536 -700 1100 0.7 0.785
02/26/13 14:45 S6 SL2 HVB7 536 -700 1150 0.93 1.05
02/26/13 14:54 S6 SL2 HVB7 536 -700 1200

trip

02/26/13 14:58 S6 SL2 HVB7 536 -700 1170 1.020 1.115
02/26/13 15:51 S6 SL2 HVB7 536 -700 1180 1.00 1.090
02/26/13 15:58 S6 SL2 HVB7 536 -700 1190 1.04 1.135
02/26/13 16:35 S6 SL2 HVB7 536 -700 1200 1.01 1.09
02/26/13 16:38 S6 SL2 HVB7 536 -700 1200 Tripped
02/26/13 16:39 S6 SL2 HVB7 536 -700 1190
02/26/13 16:48 S6 SL2 HVB7 536 -700 1193 0.915 1.005
02/26/13 16:50 S6 SL2 HVB7 536 -700 1196 Tripped
02/26/13 16:50 S6 SL2 HVB7 536 -700 1195 Tripped
02/26/13 16:57 S6 SL2 HVB7 536 -700 1194 0.920 1.015
02/26/13 17:03 S6 SL2 HVB7 536 -700 1194 Tripped
02/26/13 17:10 S6 SL2 HVB7 536 -700 1190 0.89 0.965
02/26/13 17:26 S6 SL2 HVB7 536 -700 1190 0.89 0.975
02/26/13 17:53 S6 SL2 HVB7 536 -700 1195
02/26/13 17:53 S6 SL2 HVB7 536 -700 1196 0.86
02/26/13 17:54 S6 SL2 HVB7 536 -700 1199 0.88 0.96
02/26/13 17:56 S6 SL2 HVB7 536 -700 1299 Tripped when sense got to ~1230V
02/26/13 17:58 S6 SL2 HVB7 536 -700 1199 2.055 2.135 Current trip threshold changed to 50 [math]\mu[/math]A. Upping voltage setting by a few volts at a time results in temporary (~1-2sec) spike to 30 [math]\mu[/math]A and settles back to a lower current around 2-4 [math]\mu[/math]A.
02/26/13 18:04 S6 SL2 HVB7 536 -700 1220 2.7 2.8
02/26/13 18:06 S6 SL2 HVB7 536 -700 1300 Tripped
02/26/13 18:11 S6 SL2 HVB7 536 -700 1250 15 15
02/26/13 18:12 S6 SL2 HVB7 536 -700 1250 8 8
02/26/13 18:13 S6 SL2 HVB7 536 -700 1250 4 4
02/26/13 18:14 S6 SL2 HVB7 536 -700 1250 1 1
02/26/13 18:16 S6 SL2 HVB7 536 -700 1270 2 2
02/26/13 18:17 S6 SL2 HVB7 536 -700 1270 1.4 1.5
02/26/13 18:18 S6 SL2 HVB7 536 -700 1280 2.5 2.5
02/26/13 18:19 S6 SL2 HVB7 536 -700 1280 1.5 1.6
02/26/13 18:20 S6 SL2 HVB7 536 -700 1290 1.6 1.7
02/26/13 18:21 S6 SL2 HVB7 536 -700 1290 14 14

Current spiked for about 30 seconds

02/26/13 18:22 S6 SL2 HVB7 536 -700 1290 1.5 1.6
02/26/13 18:23 S6 SL2 HVB7 536 -700 1300 8.7 8.7
02/26/13 18:24 S6 SL2 HVB7 536 -700 1300 8.2 8.3
02/26/13 18:25 S6 SL2 HVB7 536 -700 1300 7.9 8.0 Saw a spike to 44 [math]\mu[/math]A but no trip after this measurement
02/26/13 18:26 S6 SL2 HVB7 536 -700 1300 10.8 10.9
02/26/13 18:27 S6 SL2 HVB7 536 -700 1300 7.3 7.4
02/26/13 18:28 S6 SL2 HVB7 536 -700 1300 6.9 7.0
02/26/13 18:29 S6 SL2 HVB7 536 -700 1300 6.6 6.7
02/26/13 18:30 S6 SL2 HVB7 536 -700 1300 6.2 6.4
02/26/13 18:31 S6 SL2 HVB7 536 -700 1300 5.8 5.9 Current is dropping slowly. Leaving it on overnight at this voltage.
02/27/13 07:35 S6 SL2 HVB7 536 -700 1300 0.595 0.675